Konstantinos G Kyriakoulis

Dr. Konstantinos G Kyriakoulis

School of Medicine, National and Kapodistrian University of Athens, Athens, Greece, Athens, Attikí, Greece
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2021 in Hypertension
Verified
Journal Article
Closed access
PDF file
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
MYMohammad Yavarimanesh
Mohammad Yavarimanesh
KNKeerthana Natarajan
Keerthana Natarajan
JHJin-Oh Hahn
Jin-Oh Hahn
KKKonstantinos G Kyriakoulis
Konstantinos G Kyriakoulis
GSGeorge Stergiou
George Stergiou
Several novel cuffless wearable devices and smartphone applications claiming that they can measure blood pressure (BP) are appearing on the market. These technologies are very attractive and promising, with increasing interest among health care professionals for their potential use. Moreover, they are becoming popular among patients with hypertension and healthy people. However, at the present time, there are serious issues about BP measurement accuracy of cuffless devices and the 2021 European Society of Hypertension Guidelines on BP measurement do not recommend them for clinical use. Cuffless devices have special validation issues, which have been recently recognized. It is important to note that the 2018 Universal Standard for the validation of automated BP measurement devices developed by the American Association for the Advancement of Medical Instrumentation, the European Society of Hypertension, and the International Organization for Standardization is inappropriate for the validation of cuffless devices. Unfortunately, there is an increasing number of publications presenting data on the accuracy of novel cuffless BP measurement devices, with inadequate methodology and potentially misleading conclusions. The objective of this review is to facilitate understanding of the capabilities and limitations of emerging cuffless BP measurement devices. First, the potential and the types of these devices are described. Then, the unique challenges in evaluating the BP measurement accuracy of cuffless devices are explained. Studies from the literature and computer simulations are employed to illustrate these challenges. Finally, proposals are given on how to evaluate cuffless devices including presenting and interpreting relevant study results.

22 September 2016 in Journal of Educational Evaluation for Health Professions
Verified
Journal Article
Open access
PDF file
KKKonstantinos G Kyriakoulis
Konstantinos G Kyriakoulis
ATHINA PATELAROUATHINA PATELAROU
ATHINA PATELAROU
ALAggelos Laliotis
Aggelos Laliotis
AWAndrew C Wan
Andrew C Wan
MMMichail Matalliotakis
Michail Matalliotakis
EPEvridiki Patelarou
Evridiki Patelarou
Purpose: The aim of this systematic review was to find best teaching strategies for teaching evidence-based practice (EBP) to undergraduate health students that have been adopted over the last years in healthcare institutions worldwide. Methods: The authors carried out a systematic, comprehensive bibliographic search using Medline database for the years 2005 to March 2015 (updated in March 2016). Search terms used were chosen from the USNLM Institutes of Health list of MeSH (Medical Subject Headings) and free text key terms were used as well. Selected articles were measured based on the inclusion criteria of this study and initially compared in terms of titles or abstracts. Finally, articles relevant to the subject of this review were retrieved in full text. Critical appraisal was done to determine the effects of strategy of teaching evidence-based medicine (EBM). Results: Twenty articles were included in the review. The majority of the studies sampled medical students (n=13) and only few conducted among nursing (n=2), pharmacy (n=2), physiotherapy/therapy (n=1), dentistry (n=1), or mixed disciplines (n=1) students. Studies evaluated a variety of educational interventions of varying duration, frequency and format (lectures, tutorials, workshops, conferences, journal clubs, and online sessions), or combination of these to teach EBP. We categorized interventions into single interventions covering a workshop, conference, lecture, journal club, or e-learning and multifaceted interventions where a combination of strategies had been assessed. Seven studies reported an overall increase to all EBP domains indicating a higher EBP competence and two studies focused on the searching databases skill. Conclusion: Followings were deduced from above analysis: multifaceted approach may be best suited when teaching EBM to health students; the use of technology to promote EBP through mobile devices, simulation, and the web is on the rise; and the duration of the interventions varying form some hours to even months was not related to the students’ EBP competence.

1 March 2023 in Hypertension
Verified
Journal Article
Closed access
PDF file
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
SSSanjeev G. Shroff
Sanjeev G. Shroff
CLCederick Landry
Cederick Landry
KKKonstantinos G Kyriakoulis
Konstantinos G Kyriakoulis
AAAlberto Avolio
Alberto Avolio
GSGeorge Stergiou
George Stergiou
Conventional blood pressure (BP) measurement devices based on an inflatable cuff only provide a narrow view of the continuous BP profile. Cuffless BP measuring technologies could permit numerous BP readings throughout daily life and thereby considerably improve the assessment and management of hypertension. Several wearable cuffless BP devices based on pulse wave analysis (applied to a photoplethysmography or tonometry waveform) with or without use of pulse arrival time are now available on the market. The key question is: Can these devices provide accurate measurement of BP? Microsoft Research recently published a complex article describing perhaps the most important and highest resource project to date (Aurora Project) on assessing the accuracy of several pulse wave analysis and pulse wave analysis-pulse arrival time devices. The overall results from 1125 participants were clear-cut negative. The present article motivates and describes emerging cuffless BP devices and then summarizes the Aurora Project. The study methodology and findings are next discussed in the context of regulatory-cleared devices, physiology, and related studies, and the study strengths and limitations are pinpointed thereafter. Finally, the implications of the Aurora Project are briefly stated and recommendations for future work are offered to finally realize the considerable potential of cuffless BP measurement in health care.

1 August 2021 in Atherosclerosis
Verified
Journal Article
Closed access
Anastasios KolliasAnastasios Kollias
Anastasios Kollias
KKKonstantinos G Kyriakoulis
Konstantinos G Kyriakoulis
IKIOANNIS KYRIAKOULIS
IOANNIS KYRIAKOULIS
TNThomas Nitsotolis
Thomas Nitsotolis
GPGaryphallia Poulakou
Garyphallia Poulakou
KSKonstantinos Syrigos
Konstantinos Syrigos

1 June 2025 in Hypertension
Verified
Journal Article
Closed access
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
SSSanjeev G. Shroff
Sanjeev G. Shroff
KKKonstantinos G Kyriakoulis
Konstantinos G Kyriakoulis
AAAlberto Avolio
Alberto Avolio
GSGeorge Stergiou
George Stergiou
Cuffless blood pressure (BP) measurement offers considerable potential for clinical practice but is a challenging technological field. Many are investigating pulse wave analysis with or without pulse arrival time in which machine learning is applied to pulsatile waveforms obtained with mobile devices (eg, wristbands, smartphones) to estimate BP. These methods generally require individual user calibration with cuff BP measurements or demographics (eg, age, sex). This calibration makes it difficult to evaluate the method’s accuracy, and many studies claiming accuracy used inadequate testing procedures. Yet, publications and regulatory-cleared devices continue to rise, seemingly implying technological advancements. An update is provided on the flurry of activity in cuffless BP technologies over the last 2 to 3 years, covering the clinical need, the latest devices, recent publications based on pulse wave analysis and pulse arrival time, progress in developing validation standards for cuffless BP devices, and recent publications on other cuffless BP measurement principles. Despite the high volume of research and development, to date, there is no compelling evidence that pulse wave analysis and pulse arrival time can provide significant added value in BP measurement accuracy beyond the cuff BP or demographic data for calibration. Thus, it is reasonable to at least be skeptical of published and future studies on pulse wave analysis and pulse arrival time for cuffless BP measurement with uncertain testing procedures. It is important to focus on establishing robust validation standards for cuffless BP devices requiring individual user calibration and also pursuing cuffless and calibration-free BP measurement methodologies going forward.

7 November 2018 in The Journal of Clinical Hypertension
Verified
Journal Article
Open access
PDF file
GSGeorge Stergiou
George Stergiou
KKKonstantinos G Kyriakoulis
Konstantinos G Kyriakoulis
Anastasios KolliasAnastasios Kollias
Anastasios Kollias
The measurement of blood pressure in the office (OBP) remains the basis for hypertension diagnosis and management for more than half a century. Despite the increasing use of out‐of‐office blood pressure measurement using home and less so ambulatory monitoring and their endorsement by hypertension societies, at present and for some time to come it is likely that in many people the diagnosis and management of hypertension will be based on OBP measurement alone. OBP measurement is a very variable method affected by multiple factors, which have major impact on the OBP level, reproducibility and prognostic ability. Thus, there are several types of OBP measurement, depending on the device type, conditions, observer’s presence and the number of readings. The 4 main OBP types are: Type I: Auscultatory OBP in clinical practice; Type II: Automated attended OBP in clinical practice; Type III: Research setting OBP; Type IV: Unattended automated OBP. These OBP types have different standardization level, different reproducibility, different clinical relevance and different thresholds for hypertension diagnosis. Unless the methodological details of OBP measurement are reported, any conclusions based on such measurements in clinical research and in practice are questionable.