Water-level sensors are indispensable for monitoring the level of water in storage tanks, which are used in drinking water distribution networks. In this paper, a long-range capacitive-type water-level sensor is presented. The proposed sensor is constructed using widely-available multilayer tubes, which are used for building drinking water systems. Thus, both the manufacturing cost of the sensor and the cost of the associated electronic circuits, which are used for interfacing the sensor to a digital data-acquisition unit, are low. The performance of the proposed sensor has been evaluated in a water storage tank of a city-scale water distribution network. The experimental results indicate that the accuracy of the proposed experimental prototype sensor is equivalent to that of a commercially available ultrasound water level sensor, while, additionally, its manufacturing cost is significantly lower.
Human food-borne diseases caused by pathogenic bacteria have been significantly increased in the last few decades causing numerous deaths worldwide. The standard analyses used for their detection have significant limitations regarding cost, special facilities and equipment, highly trained staff, and a long procedural time that can be crucial for foodborne pathogens with high hospitalization and mortality rates, such as Listeria monocytogenes. This study aimed to develop a biosensor that could detect L. monocytogenes rapidly and robustly. For this purpose, a cell-based biosensor technology based on the Bioelectric Recognition Assay (BERA) and a portable device developed by EMBIO Diagnostics, called B.EL.D (Bio Electric Diagnostics), were used. Membrane engineering was performed by electroinsertion of Listeria monocytogenes homologous antibodies into the membrane of African green monkey kidney (Vero) cells. The newly developed biosensor was able to detect the pathogen’s presence rapidly (3 min) at concentrations as low as 102 CFU mL−1, demonstrating a higher sensitivity than most existing biosensor-based methods. In addition, lack of cross-reactivity with other Listeria species, as well as with Escherichia coli, was shown, thus, indicating biosensor’s significant specificity against L. monocytogenes.
Population growth and increased production demands on fruit and vegetables have driven agricultural production to new heights. Nevertheless, agriculture remains one of the least optimized industries, with laboratory tests that take days to provide a clear result on the chemical level of produce. To address this problem, we developed a tailor-made solution for the industry that can allow multiple field tests on key pesticides, based on a bioelectric cell biosensor and the measurement of the cell membrane potential changes, according to the principle of the Bioelectric Recognition Assay (BERA). We developed a fully functional system that operates using a newly developed hardware for multiple data sources and an Android application to provide results within 3 min. The presence of acetamiprid residues caused a cell membrane hyperpolarization, which was distinguishable from the control samples. A database that classified samples Below or Above Maximum Residue Levels (MRL) was then created, based on a newly developed algorithm. Additionally, lettuce samples were analyzed with the conventional and the newly developed method, in parallel, revealing a high correlation on sample classification. Thus, it was demonstrated that the novel biosensor system could be used in the food supply chain to increase the number of tested products before they reach the market.
The spread of the new coronavirus SARS-CoV-2 has substantial social, health, and economic impacts. High viral load in the air in hospitals poses a risk to medical personnel. Cold atmospheric plasma (CAP) is a new technology based on the emission in the air of reactive species, neutral particles, UV radiation, and electromagnetic field. CAP has the potential as an antiviral agent. In this study, an 80-day clinical trial took place at Nicosia General Hospital to evaluate the application of CAP devices for lowering the viral load in the COVID rooms. A total of 284 indoor environment samples were tested by RT-PCR, for which 9 were positive (~3% Positive Rate). After analyzing the initial results, an ion emitter was paired with each patient, and the results showed that the method could eliminate the virus from the COVID wards up to 100%. The number of patients discharged from the hospital in the ionizer group was 4.8% higher than in the non-ionizer group, and 45% fewer patients in the ionizer group who remained in the rooms required oxygen support. The clinical trial shows evidence that composite CAP can decrease coronavirus spread in hospital environments and potentially prevent virus transmission.