Krishnaswamy Nandakumar

Prof. Krishnaswamy Nandakumar

Energy Research Institute, Shandong Academy of Sciences, Jinan, Shandong, China
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2025 in Materials Science and Engineering: R: Reports
Verified
Journal Article
Closed access
CWChuang Wang
Chuang Wang
XCXingxing Cheng
Xingxing Cheng
KLKai Hong Luo
Kai Hong Luo
Krishnaswamy NandakumarKrishnaswamy Nandakumar
Krishnaswamy Nandakumar
ZWZhiqiang Wang
Zhiqiang Wang
CWChunbo Wang
Chunbo Wang

1 April 2020 in Powder Technology
Verified
Journal Article
Closed access
Shashank S TiwariShashank S Tiwari
Shashank S Tiwari
EPEshita Pal
Eshita Pal
SBShivkumar Bale
Shivkumar Bale
NMNitin Minocha
Nitin Minocha
APAshwin W. Patwardhan
Ashwin W. Patwardhan
JJJyeshtharaj Joshi
Jyeshtharaj Joshi

31 March 2015 in Soft Matter
Verified
Journal Article
Closed access
PDF file
YLYuehao Li
Yuehao Li
MJMranal Jain
Mranal Jain
YMYongting Ma
Yongting Ma
Krishnaswamy NandakumarKrishnaswamy Nandakumar
Krishnaswamy Nandakumar
Droplet-based microfluidic devices have received extensive attention in the fields of chemical synthesis, biochemical analysis, lab-on-chip devices, etc. Conventional passive microfluidic hydrodynamic flow-focusing devices (HFFDs) control the droplet breakup process by manipulating the flow ratios of the continuous phase to the dispersed phase. They confront difficulties in controlling droplet sizes in the dripping regime especially when the dispersed phase has a large viscosity. Previous studies have reported that an external electric field can be utilized as an additional tool to control the droplet breakup process in microfluidic devices. In this computational fluid dynamics (CFD) study, we have investigated the effect of an external static electric field on the droplet breakup process using the conservative level-set method coupled with the electrostatic model. The numerical simulations have demonstrated that the interaction of the electric field and the electric charges on the fluid interface induces the electric force, which plays a significant role in controlling the droplet formation dynamics. If the microfluidic system is applied with the electric field of varying strength, the droplet breakup process experiences three distinct regimes. In Regime 1, where low electric voltages are applied, the droplet size decreases almost linearly with the increase of voltage. Then the droplet size increases with the applied voltages in Regime 2, where the electric field has moderate strength. In Regime 3, where very large voltages are applied, the droplet size decreases with the applied voltage again. These interesting variations in the droplet breakup processes are explained by using transient pressure profiles in the dispersed phase and the continuous phase. The droplet breakup processes regulated by an external electric field that are revealed in this study can provide useful guidance on the design and operations of such droplet-based systems.

1 April 2020 in Powder Technology
Verified
Journal Article
Closed access
Shashank S TiwariShashank S Tiwari
Shashank S Tiwari
EPEshita Pal
Eshita Pal
SBShivkumar Bale
Shivkumar Bale
NMNitin Minocha
Nitin Minocha
APAshwin W. Patwardhan
Ashwin W. Patwardhan
JJJyeshtharaj Joshi
Jyeshtharaj Joshi

19 August 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YLYan Li
Yan Li
DLDanni Li
Danni Li
PZPei Zhao
Pei Zhao
Krishnaswamy NandakumarKrishnaswamy Nandakumar
Krishnaswamy Nandakumar
L.Q. "Rick" WangL.Q. "Rick" Wang
L.Q. "Rick" Wang
YSYou-Qiang Song
You-Qiang Song
Early detection and accurate diagnosis of Alzheimer’s disease (AD) is essential for patient care and disease treatment. Microfluidic technology is emerging as an economical and versatile platform in disease detection and diagnosis. It can be conveniently integrated with nanotechnology and/or biological models for biomedical functional and pre-clinical treatment study. These strengths make it advantageous in disease biomarker detection and functional analysis against a wide range of biological backgrounds. This review highlights the recent developments and trends of microfluidic applications in AD research. The first part looks at the principles and methods for AD diagnostic biomarker detection and profiling. The second part discusses how microfluidic chips, especially organ-on-a-chip platforms, could be used as an independent approach and/or integrated with other technologies in AD biomimetic functional analysis.

1 April 2019 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
Shashank S TiwariShashank S Tiwari
Shashank S Tiwari
SBShivkumar Bale
Shivkumar Bale
APAshwin W. Patwardhan
Ashwin W. Patwardhan
Krishnaswamy NandakumarKrishnaswamy Nandakumar
Krishnaswamy Nandakumar
JJJyeshtharaj Joshi
Jyeshtharaj Joshi
Direct numerical simulations are carried out for an incompressible flow past a stationary sphere, in the range of 100 ≤ Re ≤ 1000. It is found that the first instability occurs as the axisymmetric wake undergoes breakage at Re ≥ 250. Adding small perturbations to the flow showed that the preferred direction of breakage of the axisymmetric wake and the corresponding contribution of the y and z-direction lift coefficients are highly sensitive and get randomly affected even due to slightest perturbations that might get induced. The second instability arises at Re = 300 as large-scale hairpin shaped structures are formed and shed periodically at frequency StVS = 0.134. At Re = 350, the highly regular hairpin shedding pattern undergoes a quasiperiodic change. From the Q-criterion isosurface, we observed that the quasiperiodicity is induced due to the formation and shedding of secondary hairpin structures which are alongside the primary ones. These secondary hairpin structures are of discernable orientations and are shed 4 times slower as compared to the primary hairpins at Re = 350. Identification of these secondary hairpin structures confirms the hypothesis of wake modulation. The low-frequency mode (Stm) is captured when energy spectral analysis is performed on the surface integrated instantaneous force coefficients and on the radial velocities. The low-frequency mode further exists at all higher Re, exhibiting a gradual increase in Stm. At Re ≥ 800, shear layer instabilities are manifested, demonstrating a characteristic peak at StKH = 0.32 in the energy spectra, rendering the mean lift coefficients to become zero again.