Krishna Nayak

Prof. Krishna Nayak

University of Southern California
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HJHong Jung
Hong Jung
KSKyunghyun Sung
Kyunghyun Sung
Krishna NayakKrishna Nayak
Krishna Nayak
EKEung Yeop Kim
Eung Yeop Kim
JYJong Chul Ye
Jong Chul Ye
A model‐based dynamic MRI called k‐t BLAST/SENSE has drawn significant attention from the MR imaging community because of its improved spatio‐temporal resolution. Recently, we showed that the k‐t BLAST/SENSE corresponds to the special case of a new dynamic MRI algorithm called k‐t FOCUSS that is optimal from a compressed sensing perspective. The main contribution of this article is an extension of k‐t FOCUSS to a more general framework with prediction and residual encoding, where the prediction provides an initial estimate and the residual encoding takes care of the remaining residual signals. Two prediction methods, RIGR and motion estimation/compensation scheme, are proposed, which significantly sparsify the residual signals. Then, using a more sophisticated random sampling pattern and optimized temporal transform, the residual signal can be effectively estimated from a very small number of k‐t samples. Experimental results show that excellent reconstruction can be achieved even from severely limited k‐t samples without aliasing artifacts. Magn Reson Med 61:103–116, 2009.

8 May 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
CCCharles H. Cunningham
Charles H. Cunningham
JPJohn M. Pauly
John M. Pauly
Krishna NayakKrishna Nayak
Krishna Nayak

1 January 2015 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
Krishna NayakKrishna Nayak
Krishna Nayak
JNJon-Fredrik Nielsen
Jon-Fredrik Nielsen
MBMatt A. Bernstein
Matt A. Bernstein
MMMichael Markl
Michael Markl
PGPeter D. Gatehouse
Peter D. Gatehouse
SRSubha V. Raman
Subha V. Raman
Cardiovascular magnetic resonance (CMR) phase contrast imaging has undergone a wide range of changes with the development and availability of improved calibration procedures, visualization tools, and analysis methods. This article provides a comprehensive review of the current state-of-the-art in CMR phase contrast imaging methodology, clinical applications including summaries of past clinical performance, and emerging research and clinical applications that utilize today’s latest technology.

24 March 2004 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
SNShrikanth Narayanan
Shrikanth Narayanan
Krishna NayakKrishna Nayak
Krishna Nayak
SLSungbok Lee
Sungbok Lee
ASAbhinav Sethy
Abhinav Sethy
DBDani Byrd
Dani Byrd
Magnetic resonance imaging (MRI) has served as a valuable tool for studying static postures in speech production. Now, recent improvements in temporal resolution are making it possible to examine the dynamics of vocal-tract shaping during fluent speech using MRI. The present study uses spiral k-space acquisitions with a low flip-angle gradient echo pulse sequence on a conventional GE Signa 1.5-T CV/i scanner. This strategy allows for acquisition rates of 8–9 images per second and reconstruction rates of 20–24 images per second, making veridical movies of speech production now possible. Segmental durations, positions, and interarticulator timing can all be quantitatively evaluated. Data show clear real-time movements of the lips, tongue, and velum. Sample movies and data analysis strategies are presented.

1 April 2010 in Obesity
Verified
Journal Article
Open access
PDF file
HHHouchun H. Hu
Houchun H. Hu
HKHee‐Won Kim
Hee‐Won Kim
Krishna NayakKrishna Nayak
Krishna Nayak
MGMichael I. Goran
Michael I. Goran
The ability to accurately and noninvasively quantify fatty infiltration in organs such as the liver and the pancreas remains a critical component in understanding the link between obesity and its comorbidities such as type 2 diabetes and fatty liver disease. Single‐voxel (1H) proton magnetic resonance spectroscopy (MRS) has long been regarded as the gold‐standard noninvasive technique for such measurements. Recent advances in three‐dimensional fat–water magnetic resonance imaging (MRI) methods have led to the development of rapid, robust, and quantitative approaches that can accurately characterize the proportion of fat and water content in underlying tissues across the full imaging volume, and hence entire organs of interest. One such technique is called IDEAL (Iterative Decomposition with Echo Asymmetry and Least squares estimation). This article prospectively compares three‐dimensional (3D) IDEAL‐MRI and single‐voxel MRS in the assessment of hepatic (HFF) and pancreatic fat fraction (PFF) in 16 healthy subjects. MRS acquisitions took 3–4 min to complete whereas IDEAL acquisitions were completed in 20‐s breath‐holds. In the liver, there was a strong correlation (slope = 0.90, r2 = 0.95, P < 0.001) between IDEAL and MRS‐based fat fractions. In the pancreas, a poorer agreement between IDEAL and MRS was observed (slope = 0.32, r2 = 0.51, P < 0.02). The discrepancy of PFF is likely explained by MRS signal contamination from surrounding visceral fat, presumably during respiratory motion. We conclude that IDEAL is equally accurate in characterizing hepatic fat content as MRS, and is potentially better suited for fat quantification in smaller organs such as the pancreas.

1 January 2008 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
BGBernhard L Gerber
Bernhard L Gerber
SRSubha V Raman
Subha V Raman
Krishna NayakKrishna Nayak
Krishna Nayak
FEFrederick H Epstein
Frederick H Epstein
PFPedro Ferreira
Pedro Ferreira
DKDara L Kraitchman
Dara L Kraitchman
In less than two decades, first-pass perfusion cardiovascular magnetic resonance (CMR) has undergone a wide range of changes with the development and availability of improved hardware, software, and contrast agents, in concert with a better understanding of the mechanisms of contrast enhancement. The following review provides a perspective of the historical development of first-pass CMR, the developments in pulse sequence design and contrast agents, the relevant animal models used in early preclinical studies, the mechanism of artifacts, the differences between 1.5T and 3T scanning, and the relevant clinical applications and protocols. This comprehensive overview includes a summary of the past clinical performance of first-pass perfusion CMR and current clinical applications using state-of-the-art methodologies.