Kwang Hyeon Kim

Prof. Kwang Hyeon Kim

Department of Neurosurgery, Inje University Ilsan Paik Hospital
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SASang Hee Ahn
Sang Hee Ahn
AYAdam Unjin Yeo
Adam Unjin Yeo
KKKwang Hyeon Kim
Kwang Hyeon Kim
CKChankyu Kim
Chankyu Kim
YGYoungmoon Goh
Youngmoon Goh
JJJong Hwi Jeong
Jong Hwi Jeong
Background: Accurate and standardized descriptions of organs at risk (OARs) are essential in radiation therapy for treatment planning and evaluation. Traditionally, physicians have contoured patient images manually, which, is time-consuming and subject to inter-observer variability. This study aims to a) investigate whether customized, deep-learning-based auto-segmentation could overcome the limitations of manual contouring and b) compare its performance against a typical, atlas-based auto-segmentation method organ structures in liver cancer. Methods: On-contrast computer tomography image sets of 70 liver cancer patients were used, and four OARs (heart, liver, kidney, and stomach) were manually delineated by three experienced physicians as reference structures. Atlas and deep learning auto-segmentations were respectively performed with MIM Maestro 6.5 (MIM Software Inc., Cleveland, OH) and, with a deep convolution neural network (DCNN). The Hausdorff distance (HD) and, dice similarity coefficient (DSC), volume overlap error (VOE), and relative volume difference (RVD) were used to quantitatively evaluate the four different methods in the case of the reference set of the four OAR structures. Results: The atlas-based method yielded the following average DSC and standard deviation values (SD) for the heart, liver, right kidney, left kidney, and stomach: 0.92 ± 0.04 (DSC ± SD), 0.93 ± 0.02, 0.86 ± 0.07, 0.85 ± 0.11, and 0.60 ± 0.13 respectively. The deep-learning-based method yielded corresponding values for the OARs of 0.94 ± 0.01, 0.93 ± 0.01, 0.88 ± 0.03, 0.86 ± 0.03, and 0.73 ± 0.09. The segmentation results show that the deep learning framework is superior to the atlas-based framwork except in the case of the liver. Specifically, in the case of the stomach, the DSC, VOE, and RVD showed a maximum difference of 21.67, 25.11, 28.80% respectively. Conclusions: In this study, we demonstrated that a deep learning framework could be used more effectively and efficiently compared to atlas-based auto-segmentation for most OARs in human liver cancer. Extended use of the deep-learning-based framework is anticipated for auto-segmentations of other body sites.

26 May 2021 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
KKKwang Hyeon Kim
Kwang Hyeon Kim
HKHae-Won Koo
Hae-Won Koo
BLByung-Jou Lee
Byung-Jou Lee
SYSang-Won Yoon
Sang-Won Yoon
MSMoon-Jun Sohn
Moon-Jun Sohn

1 September 2021 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
KKKwang Hyeon Kim
Kwang Hyeon Kim
HKHae-Won Koo
Hae-Won Koo
BLByung-Jou Lee
Byung-Jou Lee
MSMoon-Jun Sohn
Moon-Jun Sohn

31 January 2022 in Spine
Verified
Journal Article
Closed access
HSHee Kwon Shin
Hee Kwon Shin
HKHae-Won Koo
Hae-Won Koo
KKKwang Hyeon Kim
Kwang Hyeon Kim
SYSang Won Yoon
Sang Won Yoon
MSMoon-Jun Sohn
Moon-Jun Sohn
BLByung-Jou Lee
Byung-Jou Lee
Study Design. Retrospective study. Objective. To evaluate the absolute value of L4 trabecular region-of-interest (t-ROI) computed tomography (CT) attenuation, which can predict pedicle screw loosening, and determine the changes in value according to number of fused levels and sagittal balance in patients undergoing lumbar fusion surgery. Summary of Background Data. Although osteoporosis was not diagnosed in spinal dual X-ray absorptiometry pre-operatively, we encountered several cases of screw loosening within 1 year of lumbar fusion surgery. Methods. We enrolled 478 patients and analyzed factors related to screw loosening. We evaluated the association between L4 t-ROI CT attenuation and screw loosening and determined the best cutoff value of t L4 t-ROI CT attenuation for predicting screw loosening. Results. The number of fused levels, postoperative C7-S1 sagittal vertical axis (SVA), and L4 t-ROI CT attenuation were independently correlated with screw loosening. According to number of fused level and postoperative C7-T1 SVA (≥36.9 mm or <36.9 mm), in patients with one-level fusion and C7-S1 SVA <36.9 mm, the optimal cutoff point of the L4 t-ROI CT attenuation predicting screw loosening was 106.5 Hounsfield unit (HU). L4 t-ROI attenuation did not change until two-level fusions. In patients with three-level fusions and C7-S1 SVA <36.9 mm, the optimal cutoff point of the L4 t-ROI CT attenuation predicting screw loosening was 159.0 HU. The optimal cutoff point of L4 t-ROI CT attenuation in patients with three-level fusions and C7-S1 SVA ≥36.9 mm was 191.0 HU. Conclusion. L4 t-ROI CT attenuation value considering number of fused levels and sagittal balance is an accurate measurement method to predict screw loosening. Spine surgeons should be aware of the L4 t-ROI attenuation before surgery to improve the fusion rate and reduce instrument-related complications of lumbar spine surgery in osteoporotic patients. Level of Evidence: 3

1 January 2024 in Korean Journal of Neurotrauma
Verified
Journal Article
Open access
PDF file
KKKwang Hyeon Kim
Kwang Hyeon Kim
JJJe Hoon Jeong
Je Hoon Jeong
MKMyeong Jin Ko
Myeong Jin Ko
SLSubum Lee
Subum Lee
WKWoo-Keun Kwon
Woo-Keun Kwon
BLByung-Jou Lee
Byung-Jou Lee
Kim KH, et al. Korean J Neurotrauma. 2024 Dec;20(4):215-224. https://doi.org/10.13004/kjnt.2024.20.e43

9 June 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KKKwang Hyeon Kim
Kwang Hyeon Kim
KPKyeongyun Park
Kyeongyun Park
HKHaksoo Kim
Haksoo Kim
BJByungdu Jo
Byungdu Jo
SASang Hee Ahn
Sang Hee Ahn
JJJong Hwi Jeong
Jong Hwi Jeong
Purpose: Imaging, breath‐holding/gating, and fixation devices have been developed to minimize setup errors so that the prescribed dose can be exactly delivered to the target volume in radiotherapy. Despite these efforts, additional patient monitoring devices have been installed in the treatment room to view patients’ whole‐body movement. We developed a facial expression recognition system using deep learning with a convolutional neural network (CNN) to predict patients’ advanced movement, enhancing the stability of the radiation treatment by giving warning signs to radiation therapists.Materials and methods: Convolutional neural network model and extended Cohn‐Kanade datasets with 447 facial expressions of source images for training were used. Additionally, a user interface that can be used in the treatment control room was developed to monitor real‐time patient's facial expression in the treatment room, and the entire system was constructed by installing a camera in the treatment room. To predict the possibility of patients' sudden movement, we categorized facial expressions into two groups: (a) uncomfortable expressions and (b) comfortable expressions. We assumed that the warning sign about the sudden movement was given when the uncomfortable expression was recognized.Results: We have constructed the facial expression monitoring system, and the training and test accuracy were 100% and 85.6%, respectively. In 10 patients, their emotions were recognized based on their comfortable and uncomfortable expressions with 100% detection rate. The detected various emotions were represented by a heatmap and motion prediction accuracy was analyzed for each patient.Conclusion: We developed a system that monitors the patient's facial expressions and predicts patient's advanced movement during the treatment. It was confirmed that our patient monitoring system can be complementarily used with the existing monitoring system. This system will help in maintaining the initial setup and improving the accuracy of radiotherapy for the patients using deep learning in radiotherapy.