Krzysztof Zaraska

Mr. Krzysztof Zaraska

Ł-IMiF
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LMLibu Manjakkal
Libu Manjakkal
KCKatarina Cvejin
Katarina Cvejin
JKJan Kulawik
Jan Kulawik
KZKrzysztof Zaraska
Krzysztof Zaraska
DSDorota Szwagierczak
Dorota Szwagierczak
Robert SochaRobert Socha
Robert Socha

1 June 2015 in Electrochimica Acta
Verified
Journal Article
Closed access
LMLibu Manjakkal
Libu Manjakkal
EDElvira Djurdjic
Elvira Djurdjic
KCKatarina Cvejin
Katarina Cvejin
JKJan Kulawik
Jan Kulawik
KZKrzysztof Zaraska
Krzysztof Zaraska
DSDorota Szwagierczak
Dorota Szwagierczak

1 December 2015 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
LMLibu Manjakkal
Libu Manjakkal
KCKatarina Cvejin
Katarina Cvejin
JKJan Kulawik
Jan Kulawik
KZKrzysztof Zaraska
Krzysztof Zaraska
DSDorota Szwagierczak
Dorota Szwagierczak
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic

15 November 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Mitar SimićMitar Simić
Mitar Simić
LMLibu Manjakkal
Libu Manjakkal
KZKrzysztof Zaraska
Krzysztof Zaraska
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic
RDRavinder Dahiya
Ravinder Dahiya
Miniaturized electrochemical pH sensors are increasingly in demand for applications such as online monitoring of water quality and health monitoring. The metal oxides are the best candidates for sensing electrodes of such sensors as they offer high chemical stability. In this paper, we present a novel approach to obtain interdigitated conductimetric pH sensor using screen printing of TiO 2 thick film on an alumina substrate. The microstructural and crystalline properties of the TiO 2 sensitive film were examined with scanning electron microscopy and Raman spectroscopy. The impedance spectroscopic studies of the fabricated thick film sensor were carried out in the frequency range of 5-20 kHz for the test solutions in the pH range of 4-10 and it was observed that the impedance of the film is distinctly dependent on pH. Using the measured impedance data, we have also proposed an equivalent RC network model for the fabricated pH sensor. The physical meaning of the model parameters was determined by electrochemical impedance spectroscopic analysis, and through statistical analysis it was found that all parameters are distinctly pH-dependent.

1 January 2016 in Talanta
Verified
Journal Article
Closed access
LMLibu Manjakkal
Libu Manjakkal
KZKrzysztof Zaraska
Krzysztof Zaraska
KCKatarina Cvejin
Katarina Cvejin
JKJan Kulawik
Jan Kulawik
DSDorota Szwagierczak
Dorota Szwagierczak

1 February 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LMLibu Manjakkal
Libu Manjakkal
BSBeata Synkiewicz-Musialska
Beata Synkiewicz-Musialska
KZKrzysztof Zaraska
Krzysztof Zaraska
KCKatarina Cvejin
Katarina Cvejin
JKJan Kulawik
Jan Kulawik
DSDorota Szwagierczak
Dorota Szwagierczak