Larissa Ribeiro

Mrs. Larissa Ribeiro

PhD candidate
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Metals
Verified
Journal Article
Open access
PDF file
BKBruna Horta Bastos Kuffner
Bruna Horta Bastos Kuffner
PCPatrícia Capellato
Patrícia Capellato
Larissa RibeiroLarissa Ribeiro
Larissa Ribeiro
Daniela SachsDaniela Sachs
Daniela Sachs
GSGilbert Silva
Gilbert Silva
Metallic biomaterials are widely used for implants and dental and orthopedic applications due to their good mechanical properties. Among all these materials, 316L stainless steel has gained special attention, because of its good characteristics as an implantable biomaterial. However, the Young’s modulus of this metal is much higher than that of human bone (~193 GPa compared to 5–30 GPa). Thus, a stress shielding effect can occur, leading the implant to fail. In addition, due to this difference, the bond between implant and surrounding tissue is weak. Already, calcium phosphate ceramics, such as beta-tricalcium phosphate, have shown excellent osteoconductive and osteoinductive properties. However, they present low mechanical strength. For this reason, this study aimed to combine 316L stainless steel with the beta-tricalcium phosphate ceramic (β-TCP), with the objective of improving the steel’s biological performance and the ceramic’s mechanical strength. The 316L stainless steel/β-TCP biocomposites were produced using powder metallurgy and functionally graded materials (FGMs) techniques. Initially, β-TCP was obtained by solid-state reaction using powders of calcium carbonate and calcium phosphate. The forerunner materials were analyzed microstructurally. Pure 316L stainless steel and β-TCP were individually submitted to temperature tests (1000 and 1100 °C) to determine the best condition. Blended compositions used to obtain the FGMs were defined as 20% to 20%. They were homogenized in a high-energy ball mill, uniaxially pressed, sintered and analyzed microstructurally and mechanically. The results indicated that 1100 °C/2 h was the best sintering condition, for both 316L stainless steel and β-TCP. For all individual compositions and the FGM composite, the parameters used for pressing and sintering were appropriate to produce samples with good microstructural and mechanical properties. Wettability and hemocompatibility were also achieved efficiently, with no presence of contaminants. All results indicated that the production of 316L stainless steel/β-TCP FGMs through PM is viable for dental and orthopedic purposes.

Verified
Journal Article
Open access
PDF file
LALetícia Faustino Adolpho
Letícia Faustino Adolpho
Larissa RibeiroLarissa Ribeiro
Larissa Ribeiro
Gileade Pereira FreitasGileade Pereira Freitas
Gileade Pereira Freitas
HLHelena Bacha Lopes
Helena Bacha Lopes
MGMaria Paula Oliveira Gomes
Maria Paula Oliveira Gomes
Adalberto Luiz RosaAdalberto Luiz Rosa
Adalberto Luiz Rosa
Background: Tissue engineering and cell therapy have been the focus of investigations on how to treat challenging bone defects. This study aimed to produce and characterize a P(VDF-TrFE)/BaTiO3 scaffold and evaluate the effect of mesenchymal stem cells (MSCs) combined with this scaffold and photobiomodulation (PBM) on bone repair. Methods and results: P(VDF-TrFE)/BaTiO3 was synthesized using an electrospinning technique and presented physical and chemical properties suitable for bone tissue engineering. This scaffold was implanted in rat calvarial defects (unilateral, 5 mm in diameter) and, 2 weeks post-implantation, MSCs were locally injected into these defects (n = 12/group). Photobiomodulation was then applied immediately, and again 48 and 96 h post-injection. The μCT and histological analyses showed an increment in bone formation, which exhibited a positive correlation with the treatments combined with the scaffold, with MSCs and PBM inducing more bone repair, followed by the scaffold combined with PBM, the scaffold combined with MSCs, and finally the scaffold alone (ANOVA, p ≤ 0.05). Conclusions: The P(VDF-TrFE)/BaTiO3 scaffold acted synergistically with MSCs and PBM to induce bone repair in rat calvarial defects. These findings emphasize the need to combine a range of techniques to regenerate large bone defects and provide avenues for further investigations on innovative tissue engineering approaches.

1 January 2025 in Biomedical Materials
Verified
Journal Article
Open access
Larissa RibeiroLarissa Ribeiro
Larissa Ribeiro
KBKrzysztof Berniak
Krzysztof Berniak
SSSunija Sukumaran
Sunija Sukumaran
RGRossano Gimenes
Rossano Gimenes
Urszula StachewiczUrszula Stachewicz
Urszula Stachewicz
Scaffolds are of great interest in tissue engineering associated with regenerative medicine owing to their ability to mimic biological structures and provide support for new tissue formation. Several techniques are used to produce biological scaffolds; among them, far-field electrospinning (FFES) process is widely used due to its versatility in producing promising structures similar to native tissues owing to the electrospun nanofibers. On the other hand, near-field electrospinning (NFES) has been investigated due to the possibility of creating scaffolds with suitable architecture for their use in specific biological tissues. Thus, we investigated the potential of the electrospun scaffolds prepared using both techniques FFES and NFES, with tailored properties to mimic bone tissue native matrix and enhance the cell response. We produced scaffolds with the piezoelectric poly(vinylidene fluoride-trifluoroethylene) combined with BaTiO3 nanoparticles. Hence, the properties of both scaffolds were evaluated in terms of crystallinity and cell behavior, such as adhesion, proliferation and cell viability. Microstructure properties showed good thermal stability, similar crystallinity (∼65%) and a β-phase content of ∼40% for both scaffolds. For biological tests, MG-63 osteoblast-like cells were used, and for NFES scaffolds, we noted that the proliferation and cell alignment followed the fiber pattern and created a bridge between adjacent fibers. In contrast, cells spread and proliferated randomly on the surface of the FFES scaffold. Despite the differences in cell behavior, both scaffolds showed good biocompatibility in terms of functional scaffolds with suitable characteristics for use in the area of tissue regeneration.

8 March 2019 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
PCPatrícia Capellato
Patrícia Capellato
Larissa RibeiroLarissa Ribeiro
Larissa Ribeiro
Daniela SachsDaniela Sachs
Daniela Sachs
O presente estudo buscou avaliar algumas metodologias ativas no processo de ensino-aprendizagem através da utilização dos seminários em conjunto com a técnica de sala de aula invertida como ferramenta educacional. Participaram deste estudo alunos da graduação do curso de Engenharia da Universidade Federal de Itajubá, em Minas Gerais, focando na componente curricular de Química Geral. A proposta constituiu na apresentação de três temas associados às Ligações Químicas: Estrutura de Lewis, Regra do Octeto e Ligação Iônica. Assim, a turma foi dividida em grupos e para cada grupo atribuiu-se um determinado tema. A avaliação do método como eficaz ou não, foi realizada considerando a opinião dos próprios discentes através de um questionário avaliativo. Os resultados obtidos através da aplicação dessa metodologia foram satisfatórios, visto que grande parte da turma contribuiu de forma positiva para que os seminários fossem concluídos. Através deste estudo conclui-se que as metodologias ativas são responsáveis por promover habilidades tanto sociais quanto acadêmicas no discente, como discussão, argumentação, oratória e audição, conferindo assim uma maior dinamicidade ao processo de ensino-aprendizagem.

26 August 2022 in Metals
Verified
Journal Article
Open access
PDF file
Larissa RibeiroLarissa Ribeiro
Larissa Ribeiro
LSLuziane Aparecida Costa da Rosa Simões
Luziane Aparecida Costa da Rosa Simões
MEMelina Espanhol-Soares
Melina Espanhol-Soares
VTVinicius Carvalho Teles
Vinicius Carvalho Teles
TRTainara Aparecida Nunes Ribeiro
Tainara Aparecida Nunes Ribeiro
RGRossano Gimenes
Rossano Gimenes
This study aims to promote an adequate methodology for coating an experimental Ti-30Ta alloy with P(VDF-TrFE)/BaTiO3. The combination of a copolymer with a ceramic has not been used until now. Ti-30Ta is an excellent choice to replace current alloys in the global market. The composite deposition on the Ti-30Ta substrate was performed by a spray coating process and at low temperature using two different surface modifications: surface acidic etching and surface polishing. Characterization was divided into four areas: (I) the substrate surface treatments used and their influences on the adhesion process were evaluated using surface energy, wettability, and roughness analyses; (II) the properties of the composite film, which were carried out using X-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TG), and differential scanning calorimetry (DSC); (III) the study of the adhesion of the film on the substrate, which was performed by a scratch test; (IV) the final product, which was evaluated to determine the surface properties after the coating process. Biofilm formation using Staphylococcus aureus and Staphylococcus epidermidis strains and a hemocompatibility test were performed as biological assays. The results indicated that the P(VDF-TrFE)/BaTiO3 film showed high thermal stability (up to ≈450 °C); the FTIR and DSC tests indicated the presence of the β phase, which means that the material presents a piezoelectric nature; and the scratch test showed that the samples with the polish treatment provided a better adhesion of the film with an adhesion strength of ~10 MPa. From the SEM analysis, it was possible to determine that the spray deposition coating process resulted in a well-applied film as evidenced by its homogeneity. Microbiological tests showed that for Staphylococcus aureus, the bacterial growth in the coated Ti-30Ta presented no significant differences when compared to the alloy without coating. However, for Staphylococcus epidermidis, there was considerable growth on the coated Ti-30Ta, when compared to the non-coated alloy, indicating that the film surface may have favored bacterial growth. The hemolysis assay showed that the coated material presents hemocompatible characteristics when in contact with blood cells. The results obtained indicate that the Ti-30Ta alloy coated with P(VDF-TrFE)/BaTiO3 is a promising alternative for implant applications, due to its biocompatible properties, simplicity, and low cost.