May Nak Lau

Dr. May Nak Lau

Lecturer
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Chia Wei CheahChia Wei Cheah
Chia Wei Cheah
NANM Al-Namnam
NM Al-Namnam
MLMay Nak Lau
May Nak Lau
GLGhee Seong Ghee Lim
Ghee Seong Ghee Lim
RRRenukanth Raman
Renukanth Raman
WNWei Cheong Ngeow
Wei Cheong Ngeow
Alloplasts are synthetic, inorganic, biocompatible bone substitutes that function as defect fillers to repair skeletal defects. The acceptance of these substitutes by host tissues is determined by the pore diameter and the porosity and inter-connectivity. This narrative review appraises recent developments, characterization, and biological performance of different synthetic materials for bone, periodontal, and dental tissue regeneration. They include calcium phosphate cements and their variants β-tricalcium phosphate (β-TCP) ceramics and biphasic calcium phosphates (hydroxyapatite (HA) and β-TCP ceramics), calcium sulfate, bioactive glasses and polymer-based bone substitutes which include variants of polycaprolactone. In summary, the search for synthetic bone substitutes remains elusive with calcium compounds providing the best synthetic substitute. The combination of calcium sulphate and β-TCP provides improved handling of the materials, dispensing with the need for a traditional membrane in guided bone regeneration. Evidence is supportive of improved angiogenesis at the recipient sites. One such product, (EthOss® Regeneration, Silesden, UK) has won numerous awards internationally as a commercial success. Bioglasses and polymers, which have been used as medical devices, are still in the experimental stage for dental application. Polycaprolactone-TCP, one of the products in this category is currently undergoing further randomized clinical trials as a 3D socket preservation filler. These aforementioned products may have vast potential for substituting human/animal-based bone grafts.

1 May 2010 in Oral Oncology
Verified
Journal Article
Closed access
ASA. Saleh
A. Saleh
RZR.B. Zain
R.B. Zain
HHHaizal Mohd Hussaini
Haizal Mohd Hussaini
FNF. Ng
F. Ng
VTVivek Tanavde
Vivek Tanavde
SCS.C. Cheong
S.C. Cheong

3 January 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZSZhi Kuan Saw
Zhi Kuan Saw
JYJonathan Jun Xian Yuen
Jonathan Jun Xian Yuen
AAASMA ASHARI
ASMA ASHARI
FBFatima Ibrahim Bahemia
Fatima Ibrahim Bahemia
YLYun Xuan Low
Yun Xuan Low
MLMay Nak Lau
May Nak Lau
This study aimed to assess the validity and reliability of a questionnaire on patient acceptance of orthodontic retainers. The original questionnaire was forward- and backward-translated, followed by four validity tests (content validity, face validity, construct validity, criterion validity) and two reliability tests (test-retest reliability, internal consistency). Content validity was assessed by nine orthodontists who appraised the questionnaire’s representativeness, relevance, clarity, and necessity. Face validity was established through semi-structured in-depth interviews with 35 English-literate participants currently wearing orthodontic retainers. Construct validity was established through Exploratory Factor Analysis (EFA). For criterion validity, 107 participants concurrently answered the questionnaire and the Retainer-modified Malaysian Oral Health Impact Profile questionnaire. Test-retest reliability was verified by 34 subjects who responded to the questionnaire again after a two-week interval. Six revised items passed the threshold value of 0.78 for Item-Content Validity Index and Content Validity Ratio and were revised based on findings from the face validity test. Principal Component Analysis of EFA extracted information on only one component, and all items were positively correlated with the component matrix. Spearman’s rho value (rs = 0.490 and rs = 0.416) indicated a moderate correlation between the two questionnaires for criterion validity. Intraclass Correlation Coefficient ranged from 0.687 to 0.913, indicating moderate to excellent test-retest reliability. Cronbach’s alpha ranged from 0.687 to 0.913 indicating that none of the questionnaire items showed unacceptable or poor internal consistency. The questionnaire on patient acceptance of orthodontic retainers has been validated and can be used in both clinical and research settings.

7 June 2021 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
SSSaritha Sivarajan
Saritha Sivarajan
ESEunice Xinwei Soh
Eunice Xinwei Soh
NZNor Nadia Zakaria
Nor Nadia Zakaria
YKYasmin Kamarudin
Yasmin Kamarudin
MLMay Nak Lau
May Nak Lau
ZNZahra Naimie
Zahra Naimie
Background: Wire-bending skills is commonly taught through live demonstrations (LD) though flipped classroom (FC) method has gained popularity. Continuous formative assessment promotes personalised learning via closely monitored progress, with the identification of students’ strengths and weaknesses. This study aims to evaluate the effects of LD and FC teaching methods, supplemented with continuous formative assessment, on dental students’ learning of wire-bending skills for six types of removable orthodontic appliance components. A deeper understanding of the relative effectiveness between LD and FC teaching methods can help identify the most appropriate method to achieve student learning objectives, which is especially important given the current Covid-19 pandemic. Methods: Forty third-year undergraduate dental students were randomly assigned into FC (n = 20) or LD (n = 20) cohort. Each student attended six teaching sessions, each to teach students’ competency in fabricating one type of wire component, for a total competency in fabricating six wire components over the course of six teaching sessions. Either LD or FC teaching methods were used. After each session, wire assignments had to be submitted. Wire assignments were then evaluated using a blinded wire-bending assessment protocol. As part of their formative assessment, the assessment results were distributed to students, lecturers, and technicians before the next session. After the first session (T0) and at the end of all six sessions (T1), students completed a self-reported questionnaire. Results: The mean wire-bending scores for FC were significantly higher than LD for two of the six assignments, namely the Adams clasp (p < 0.01) and Z-spring (p = 0.03). Scores for both LD and FC increased significantly over time, which may be attributed to formative assessment. There was no statistically significant correlation between wire-bending scores and video usage. Students were satisfied with both teaching methods, according to T0 and T1 questionnaires. Conclusions: Both LD and FC are equally effective in transferring practical orthodontic wire-bending skills and well-received by students. Continuous formative assessment may have enhanced students’ learning of orthodontic wire-bending skills. Further studies with control group are recommended to investigate the effect of formative assessment on teaching practical dental skills.

26 August 2022 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
AAASMA ASHARI
ASMA ASHARI
NMNik Mukhriz Nik Mustapha
Nik Mukhriz Nik Mustapha
JYJonathan Jun Xian Yuen
Jonathan Jun Xian Yuen
ZSZhi Kuan Saw
Zhi Kuan Saw
MLMay Nak Lau
May Nak Lau
SSSindhu Sinnasamy
Sindhu Sinnasamy
Objectives: To compare the clinical effectiveness of Hawley retainers (HRs) and modified vacuum-formed retainers (mVFRs) with palatal coverage in maintaining transverse expansion throughout a 24-month retention period and to assess the subjects’ perception toward the retainers.Materials and methods: The trial accomplished blinding only by the outcome assessor and data analyst. Data were collected from post-orthodontic treatment patients who met the inclusion criteria. Thirty-five subjects were randomly allocated using a centralized randomization technique into either mVFR (n = 18) or HR group (n = 17). Dental casts of subjects were evaluated at debond (T0), 3-month (T1), 6-month (T2), 12-month (T3), and 24-month retention (T4). The intercanine width (ICW), interpremolar width (IPMW), interfirst molar mesiobuccal cusp width (IFMW1), and interfirst molar distobuccal cusp width (IFMW2) were compared between groups over time using Mixed ANOVA. A pilot-tested and validated questionnaire consisting of six items were given at T4. Subjects were instructed to rate their retainer in terms of fitting, speech, appearance, oral hygiene, durability, and comfort on a 100-mm Visual Analogue Scale (VAS).Results: No statistically significant differences in arch width were found between the two groups at ICW (P = .83), IPMW (P = 0.63), IFMW1 (P = .22), and IFMW2 (P = .46) during the 24-month retention period. Also, no statistically significant differences were found between perception of both retainers in terms of fitting, speech, oral hygiene, durability, and comfort (P > .05) after 24-month wear. The appearance of mVFRs was rated significantly higher compared to HRs (P < .05).Conclusions: HR and mVFR have similar clinical effectiveness for retention of transverse expansion cases in a 24-month retention period. Both retainers were perceived to be equal in terms of fitting, speech, oral hygiene, durability, and comfort. Subjects in the mVFRs group found their retainers to be significantly more esthetic than those in HRs group.

9 July 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MLMay Nak Lau
May Nak Lau
YKYasmin Kamarudin
Yasmin Kamarudin
NZNor Nadia Zakaria
Nor Nadia Zakaria
SSSaritha Sivarajan
Saritha Sivarajan
NTNorhidayah @ Nor Zahidah Mohd Tahir
Norhidayah @ Nor Zahidah Mohd Tahir
WHWan N. Wan Hassan
Wan N. Wan Hassan
Flipped classroom may overcome weaknesses of live demonstration in teaching orthodontic wire-bending. This study aims to compare the effectiveness between flipped classroom and live demonstration in transferring skills for fabricating Adams clasp. Forty third-year undergraduate dental students were assigned to two groups. The students in group LD (n = 20) attended a live demonstration while students in group FC (n = 20) attended a flipped classroom. Both groups were taught on skills to fabricate Adams clasp in a standardised way. Each student from both groups were asked to submit an Adams clasp for a blinded quality assessment by two trained and calibrated assessors using a 18-item rubric, followed by validated students’ satisfaction questionnaires to evaluate their perceived satisfaction on the teaching method received. A crossover study was then conducted three weeks later where LD attended a flipped classroom while FC attended a live demonstration. Students’ satisfaction questionnaires were again collected from each student for blinded analysis. Mean scores for the quality of Adams clasp were 9.775 and 9.125 for LD and FC, respectively. No significant difference was detected between the two groups. Statistically significant association was found for one statement on the questionnaire, “I found the classroom arrangements conducive for the wire-bending activity” (p = 0.010). No significant differences were found between the two groups for other statements (p > 0.05). In conclusion, within the limitations of the study, flipped classroom is equally effective as conventional live demonstration in transferring orthodontic wire-bending skills for fabrication of Adams clasp. However, students perceived the classroom arrangements during the flipped classroom significantly more conducive for teaching orthodontic wire-bending.