Lexuan Zhong

Prof. Lexuan Zhong

University of Alberta
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Building and Environment
Verified
Journal Article
Closed access
Lexuan ZhongLexuan Zhong
Lexuan Zhong
FHFariborz Haghighat
Fariborz Haghighat

1 October 2013 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
Lexuan ZhongLexuan Zhong
Lexuan Zhong
FHFariborz Haghighat
Fariborz Haghighat
CLChang-Seo Lee
Chang-Seo Lee
NLNess Lakdawala
Ness Lakdawala


1 December 2012 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
Lexuan ZhongLexuan Zhong
Lexuan Zhong
CLChang-Seo Lee
Chang-Seo Lee
FHFariborz Haghighat
Fariborz Haghighat

1 November 2017 in Applied Catalysis B: Environment and Energy
Verified
Journal Article
Closed access
Lexuan ZhongLexuan Zhong
Lexuan Zhong
JBJames J. Brancho
James J. Brancho
Stuart BattermanStuart Batterman
Stuart Batterman
BBBart M. Bartlett
Bart M. Bartlett
CGChristopher Godwin
Christopher Godwin

Lexuan ZhongLexuan Zhong
Lexuan Zhong
FSFeng-Chiao Su
Feng-Chiao Su
Stuart BattermanStuart Batterman
Stuart Batterman
Exposure to volatile organic compounds (VOCs) has been an indoor environmental quality (IEQ) concern in schools and other buildings for many years. Newer designs, construction practices and building materials for “green” buildings and the use of “environmentally friendly” products have the promise of lowering chemical exposure. This study examines VOCs and IEQ parameters in 144 classrooms in 37 conventional and high performance elementary schools in the U.S. with the objectives of providing a comprehensive analysis and updating the literature. Tested schools were built or renovated in the past 15 years, and included comparable numbers of conventional, Energy Star, and Leadership in Energy and Environmental Design (LEED)-certified buildings. Indoor and outdoor VOC samples were collected and analyzed by thermal desorption, gas chromatography and mass spectroscopy for 94 compounds. Aromatics, alkanes and terpenes were the major compound groups detected. Most VOCs had mean concentrations below 5 µg/m3, and most indoor/outdoor concentration ratios ranged from one to 10. For 16 VOCs, the within-school variance of concentrations exceeded that between schools and, overall, no major differences in VOC concentrations were found between conventional and high performance buildings. While VOC concentrations have declined from levels measured in earlier decades, opportunities remain to improve indoor air quality (IAQ) by limiting emissions from building-related sources and by increasing ventilation rates.