Wei Liu

Dr. Wei Liu

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
WLWei Liu
Wei Liu
PXPeng Xi
Peng Xi
JLJiguo Liu
Jiguo Liu
XXXilong Xu
Xilong Xu
ZXZhaoheng Xie
Zhaoheng Xie
QRQiushi Ren
Qiushi Ren
This work reports the performance evaluation of a newly developed small-animal positron emission tomography (PET) system based on lutetium-yttrium oxyorthosilicate (LYSO) crystals and multi-pixel photon counter (MPPC). Performance was evaluated, including spatial resolution, system sensitivity, energy resolution, scatter fraction (SF), noise–equivalent count rate (NECR), micro-Derenzo phantom imaging, and in vivo imaging of mice and rats. The system achieved a tangential spatial resolution of 0.9 mm in the axial direction at a quarter axial offset using the three-dimensional ordered-subsets expectation maximization (3D OSEM) reconstruction algorithm. The peak sensitivity was 8.74% within a 200–750 keV energy window, with an average energy resolution of 12.5%. Scatter fractions were 12.9% and 30.0% for mouse- and rat-like phantoms, respectively. The NECR reached 878.7 kcps at 57.6 MBq for the mouse phantom and 421.4 kcps at 63.2 MBq for the rat phantom. High-resolution phantom and in vivo images confirmed the system’s capability for quantitative, high-sensitivity small-animal imaging, demonstrating its potential for preclinical molecular imaging studies.

28 September 2026 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ZDZhengkun Dong
Zhengkun Dong
XJXiao Jin
Xiao Jin
XMXiangxi Meng
Xiangxi Meng
WLWei Liu
Wei Liu
NLNan Li
Nan Li
ZXZhaoheng Xie
Zhaoheng Xie
Objective. Quantitative imaging-based dosimetry is essential for optimizing [ 177 Lu]Lu-DOTATATE peptide receptor radionuclide therapy, yet full multi-time-point (MTP) SPECT/CT is difficult to implement in routine clinical practice. This study proposes a hybrid planar-SPECT framework for organ-level time-integrated activity (TIA) estimation and single-time-point (STP)-constrained voxel-level Monte Carlo (MC) dose analysis from a single post-therapy SPECT/CT acquisition. Approach. The proposed framework integrates STP SPECT/CT with serial planar imaging to derive organ-level TIAs. A physics-informed support vector regression (SVR) model is incorporated to refine planar-to-SPECT scaling factors and improve the robustness of planar-derived activity quantification. The resulting organ TIAs are used to scale the fixed within-organ STP SPECT pattern and generate voxelized TIA maps as source distributions for MC-based dose calculation. The method is evaluated against reference MTP SPECT/CT data in 11 patients and further applied to a separate cohort of 23 patients to explore vertebral dose heterogeneity and its association with hematologic toxicity. Main results. Hybrid dosimetry showed good agreement with MTP SPECT/CT, with organ-level errors of approximately 10%–15%. The SVR-based refinement modestly reduced scaling bias, particularly in anatomically challenging structures. Voxel-level vertebral dose heterogeneity metrics showed moderate but exploratory correlations with hematologic toxicity ( ρ ≈ 0.4–0.5) after false-discovery-rate correction, whereas conventional organ-averaged dose metrics showed no significant association. Significance. The proposed hybrid planar-SPECT framework supports clinically feasible organ-level dosimetry from a reduced acquisition protocol. The resulting voxelized maps provide STP-constrained approximate source distributions for MC dose calculation and exploratory characterization of spatial dose heterogeneity, rather than reconstructions of time-varying MTP voxel kinetics. The SVR improvement observed in the 11-patient internal validation remains preliminary, requiring larger cohorts for robustness and external validation for generalizability.

15 October 2026 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ZWZhao Wang
Zhao Wang
XZXin Zhao
Xin Zhao
ZDZhengkun Dong
Zhengkun Dong
WLWei Liu
Wei Liu
QPQiyu Peng
Qiyu Peng
ZXZhaoheng Xie
Zhaoheng Xie
Objective. Depth-of-interaction (DOI)-enabled long axial field-of-view (LAFOV) positron emission tomography (PET) can mitigate parallax-induced resolution degradation, but DOI modeling substantially expands the lines-of-response space and increases computational cost. This study aimed to develop a scalable reconstruction framework for DOI-enabled LAFOV-PET. Approach. We present an optimized multi-GPU reconstruction framework based on list-mode ordered-subsets expectation maximization. The framework targets the major computational bottlenecks of DOI-enabled LAFOV-PET reconstruction, including sensitivity image calculation and Monte Carlo-based scatter estimation. Main results. The extended IQ phantom demonstrated near-linear scalability across multiple GPUs for sensitivity image calculation and Monte Carlo-based scatter estimation. Additional Derenzo and hybrid anthropomorphic phantom studies validated the imaging benefits of DOI modeling, including improved spatial resolution and performance under realistic imaging conditions. Significance. The proposed framework improves the scalability of DOI-enabled LAFOV-PET reconstruction by enabling its dominant computational components to efficiently utilize available GPU resources, establishing a foundation for high-performance reconstruction in next-generation PET systems.

17 February 2026 in Medical Image Analysis
Verified
Journal Article
Closed access
KMKun Ma
Kun Ma
FCFangxiao Cheng
Fangxiao Cheng
WLWei Liu
Wei Liu
WSWenrui Shao
Wenrui Shao
YYYalei Yang
Yalei Yang
ZXZhaoheng Xie
Zhaoheng Xie