Qiong Liu

Ms. Qiong Liu

Xuzhou Medical University, Xuzhou, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
QLQiong Liu
Qiong Liu
LCLi Chaofan
Li Chaofan
TJTeng Jinnan
Teng Jinnan
CLChen Liping
Chen Liping
JSJianxiang Song
Jianxiang Song
Convolutional Neural Networks (CNNs) have achieved remarkable segmentation accuracy in medical image segmentation tasks. However, the Vision Transformer (ViT) model, with its capability of extracting global information, offers a significant advantage in contextual information compared to the limited receptive field of convolutional kernels in CNNs. Despite this, ViT models struggle to fully detect and extract high-frequency signals, such as textures and boundaries, in medical images. These high-frequency features are essential in medical imaging, as targets like tumors and pathological organs exhibit significant differences in texture and boundaries across different stages. Additionally, the high resolution of medical images leads to computational complexity in the self-attention mechanism of ViTs. To address these limitations, we propose a medical image segmentation network framework based on frequency domain decomposition using a Laplacian pyramid. This approach selectively computes attention features for high-frequency signals in the original image to enhance spatial structural information effectively. During attention feature computation, we introduce Singular Value Decomposition (SVD) to extract an effective representation matrix from the original image, which is then applied in the attention computation process for linear projection. This method reduces computational complexity while preserving essential features. We demonstrated the segmentation validity and superiority of our model on the Abdominal Multi-Organ Segmentation dataset and the Dermatological Disease dataset, and on the Synapse dataset our model achieved a score of 82.68 on the Dice metrics and 17.23 mm on the HD metrics. Experimental results indicate that our model consistently exhibits segmentation effectiveness and improved accuracy across various datasets.

12 July 2021 in Medical Physics
Verified
Journal Article
Closed access
PDF file
QLQiong Liu
Qiong Liu
CLChaofan Li
Chaofan Li
JLJiguo Liu
Jiguo Liu
KKKishore Krish
Kishore Krish
XFXinlei Fu
Xinlei Fu
Jyh-Cheng ChenJyh-Cheng Chen
Jyh-Cheng Chen

23 December 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CLChaofan Li
Chaofan Li
QLQiong Liu
Qiong Liu
JSJianxiang Song
Jianxiang Song
Medical image segmentation is a fundamental task in computer-aided diagnosis, playing a crucial role in organ structure analysis, lesion delineation, and treatment planning. However, current Transformer-based segmentation networks still face two major challenges. First, the global self-attention in the encoder often introduces redundant connections, leading to high computational cost and potential interference from irrelevant tokens. Second, the decoder shows limited capability in reconstructing fine-grained boundary structures, resulting in blurred segmentation contours. To address these issues, we proposed an efficient and accurate framework for general medical image segmentation. Specifically, in the encoder, we introduce a frequency-domain similarity measure and construct a Key-Semantic Dictionary (KSD) via amplitude spectrum cosine similarity. This enables stage-wise sparse attention matrices that reduce redundancy and enhance semantic relevance. In the decoder, we design a learnable gradient-based operator that injects boundary-aware logits bias into the attention mechanism, thereby improving structural detail recovery along object boundaries. On ACDC, the framework delivers a 0.55% gain in average Dice and a 14.6% reduction in HD over the second-best baseline. On ISIC 2018, it achieves increases of 1.01% in Dice and 0.21% in ACC over the second-best baseline, while using 88.8% fewer parameters than typical Transformer-based models. On Synapse, it surpasses the strongest prior approach by 1.03% in Dice and 6.35% in HD, yielding up to 8.36% Dice improvement and 52.46% HD reduction compared with widely adopted Transformer baselines. Comprehensive results confirm that the proposed frequency-domain sparse attention and learnable edge-guided decoding effectively balance segmentation accuracy, boundary fidelity, and computational cost. This framework not only suppresses redundant global correlations and enhances structural detail reconstruction, but is also robust to different medical imaging modalities, providing a lightweight and clinically applicable solution for high-precision medical image segmentation.

25 December 2025 in IEEE Access
Verified
Journal Article
Open access
CLChaofan Li
Chaofan Li
QLQiong Liu
Qiong Liu
JTJinnan Teng
Jinnan Teng
Accurate boundary segmentation of anatomically complex structures such as organs and tumors remains a major challenge in medical image analysis. Traditional segmentation methods often overlook the extraction of high-frequency information such as texture and boundary details, despite their critical importance in guiding clinical surgical planning. To address this issue, we proposed a hierarchical frequency-domain enhancement strategy in the encoder, which performs effective separation and reconstruction of high- and low-frequency features via Fourier transform combined with a low-pass masking operation. This design enhances the model’s sensitivity to high-frequency texture and fine-grained boundary signals. Furthermore, in the decoder, we introduce a boundary refinement mechanism that dynamically combines Scharr operators with Laplacian-based sharpening to enhance structural clarity. This effectively alleviates segmentation discontinuities and boundary fragmentation issues commonly observed in regions with blurred edges using conventional methods. We conduct extensive experiments on both the BraTS 2020 MRI dataset and the Synapse CT dataset. Our method achieves an average Dice score of 86.79% on BraTS 2020 and 84.23% on Synapse, representing relative improvements of 0.99% and 0.90%, respectively, over strong state-of-the-art baselines. In terms of boundary precision, our approach reduces the 95% Hausdorff Distance (HD) by 13.2% on BraTS 2020 and 30.1% on Synapse, demonstrating superior boundary segmentation capability. Ablation studies further validate the effectiveness of each proposed component.

11 May 2022 in Electronics
Verified
Journal Article
Open access
PDF file
JZJie Zhao
Jie Zhao
QLQiong Liu
Qiong Liu
CLChaofan Li
Chaofan Li
YSYunfeng Song
Yunfeng Song
YZYing Zhang
Ying Zhang
Jyh-Cheng ChenJyh-Cheng Chen
Jyh-Cheng Chen
Purpose: The aim of this study was to investigate the optimization of the spatial resolution and image reconstruction parameters related to image quality in an iterative reconstruction algorithm for the small-animal Metis™ PET/CT system. Methods: We used a homemade Derenzo phantom to evaluate the image quality using visual assessment, the signal-to-noise ratio, the contrast, the coefficient of variation, and the contrast-to-noise ratio of the 0.8 mm hot rods of eight slices in the center of the phantom PET images. A healthy mouse study was performed to analyze the influence of the optimal reconstruction parameters and the Gaussian post-filter FWHM. Results: In the phantom study, the image quality was the best when the phantom was placed at the end, keeping the central axis parallel to the X-axis of the system, and selecting between 30 and 40 iterations, a 0.314 mm reconstructed voxel size, and a 1.57 mm Gaussian post-filter FWHM. The optimization of the spatial resolution could reach 0.6 mm. In the animal study, it was suitable to choose a voxel size of 0.472 mm, between 30 and 40 iterations, and a 2.36 mm Gaussian post-filter FWHM. Conclusions: Our results indicate that the optimal imaging conditions and reconstruction parameters are very necessary to obtain high-resolution images and quantitative accuracy, especially for the high-precision recognition of tiny lesions.

9 March 2023 in Electronics
Verified
Journal Article
Open access
PDF file
JZJie Zhao
Jie Zhao
YSYunfeng Song
Yunfeng Song
QLQiong Liu
Qiong Liu
SCShijie Chen
Shijie Chen
Jyh-Cheng ChenJyh-Cheng Chen
Jyh-Cheng Chen
Positron emission tomography (PET) is a popular research topic. People are becoming more interested in PET images as they become more widely available. However, the partial volume effect (PVE) in PET images remains one of the most influential factors causing the resolution of PET images to degrade. It is possible to reduce this PVE and achieve better image quality by measuring and modeling the point spread function (PSF) and then accounting for it inside the reconstruction algorithm. In this work, we examined the response characteristics of the MetisTM PET/CT system by acquiring 22Na point source at different locations in the field of view (FOV) of the scanner and reconstructing with small pixel size for images to obtain their radial, tangential, and axial full-width half maximum (FWHM). An image-based model of the PSF model was then obtained by fitting asymmetric two-dimensional Gaussians on the 22Na images. This PSF model determined by FWHM in three directions was integrated into a three-dimensional ordered subsets expectation maximization (3D-OSEM) algorithm based on a list-mode format to form a new PSF-OSEM algorithm. We used both algorithms to reconstruct point source, Derenzo phantom, and mouse PET images and performed qualitative and quantitative analyses. In the point source study, the PSF-OSEM algorithm reduced the FWHM of the point source PET image in three directions to about 0.67 mm, and in the phantom study, the PET image reconstructed by the PSF-OSEM algorithm had better visual effects. At the same time, the quantitative analysis results of the Derenzo phantom were better than the original 3D-OSEM algorithm. In the mouse experiment, the results of qualitative and quantitative analyses showed that the imaging quality of PSF-OSEM algorithm was better than that of 3D-OSEM algorithm. Our results show that adding the PSF model to the 3D-OSEM algorithm in the MetisTM PET/CT system helps to improve the resolution of the image and satisfy the qualitative and quantitative analysis criteria.