The metasurface refractive index sensor has a high degree of tunability and flexibility, providing excellent performance for high precision refractive index sensing applications. The metasurface absorber with metallic structure has been hindered in further sensor applications due to the inherent Ohmic loss of the metallic material. In this study, a dual nanorod metasurface structure based on semiconductor Si was designed, introducing a symmetry‐breaking structure to excite dual ultra‐narrow q‐BIC resonance peaks with Fano line shapes. Both peaks are located in the near‐infrared region, and multipole analysis shows that this strong field enhancement effect is induced by a magnetic dipole. Experimental results demonstrate the potential of this sensor to provide dual‐channel detection while achieving high sensitivity and high Q‐factor. We believe that this device exhibits outstanding performance and high practicality, providing a reference for the development and application of biological and environmental sensors.
To address the shortcomings in many traditional spectral feature extraction algorithms in practical application of low modeling accuracy and poor stability, this paper introduces the “Boruta algorithm-based local optimization process“ based on the traditional simulated annealing algorithm and proposes the “two-step simulated annealing algorithm (TSSA)”. This algorithm combines global optimization and local optimization. The Boruta algorithm ensures that the feature extraction results are all strongly correlated with the dependent variable, reducing data redundancy. The accuracy and stability of the algorithm model are significantly improved. The experimental results show that compared with the traditional feature extraction method, the accuracy indexes of the inversion model established by using the TSSA algorithm for feature extraction were significantly improved, with the determination coefficient R2 of 0.9654, the root mean square error (RMSE) of 3.6723 μg/L, and the mean absolute error (MAE) of 3.1461 μg/L.
A tomographic microscopy system can achieve instantaneous three-dimensional imaging, and this type of microscopy system has been widely used in the study of biological samples; however, existing chromatographic microscopes based on off-axis Fresnel zone plates have degraded image quality due to geometric aberrations such as spherical aberration, coma aberration, and image scattering. This issue hinders the further development of chromatographic microscopy systems. In this paper, we propose a method for the design of an off-axis Fresnel zone plate with the elimination of aberrations based on double exposure point holographic surface interference. The aberration coefficient model of the optical path function was used to solve the optimal recording parameters, and the principle of the aberration elimination tomography microscopic optical path was verified. The simulation and experimental verification were carried out utilizing a Seidel coefficient, average gradient, and signal-to-noise ratio. First, the aberration coefficient model of the optical path function was used to solve the optimal recording parameters. Then, the laminar mi-coroscopy optical system was constructed for the verification of the principle. Finally, the simulation calculation results and the experimental results were verified by comparing the Seidel coefficient, average gradient, and signal-to-noise ratio of the microscopic optical system before and after the aberration elimination. The results show that for the diffractive light at the orders 0 and ±1, the spherical aberration W040 decreases by 62–70%, the coma aberration W131 decreases by 96–98%, the image dispersion W222 decreases by 71–82%, and the field curvature W220 decreases by 96–96%, the average gradient increases by 2.8%, and the signal-to-noise ratio increases by 18%.
11 December 2024 in Advanced Materials Technologies