Liviu Neamt

Dr. Liviu Neamt

Electrical, Electronic and Computer Engineering, Technical University of Cluj-Napoca, Cluj-Napoca, Cluj, Romania
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2021 in IEEE Access
Verified
Journal Article
Open access
Liviu NeamtLiviu Neamt
Liviu Neamt
Olivian ChiverOlivian Chiver
Olivian Chiver
To balance the potential distribution on the surface of a substation, an equal spacing arrangement of the grounding grid conductors is not an economical solution. The implementable solution is an unequal placement of its constituent elements. The design methodologies of such a configuration are complex and require computer-assisted numerical analysis. This paper proposes and validates a simple method of arranging the conductors of the grounding grid that guarantees the reduction of touch and step voltages, ensures the efficiency of the material used and has no limitations on its applicability for atypical substation surfaces (too large or too small), respectively for few or many parallel conductors. The proposed algorithm is analyzed, through the CYMGRD Substation Grounding Program, compared to the technologies currently applied, for the substation grounding grid presented as an example in the IEEE Guide for Safety in AC Substation Grounding 80 ™ -2013 standard.

18 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
Olivian ChiverOlivian Chiver
Olivian Chiver
ISIoan Radu Sugar
Ioan Radu Sugar
Liviu NeamtLiviu Neamt
Liviu Neamt
Hybrid electric vehicles (HEVs) are perceived as a first step toward the future of sustainable transport. Of course, battery electric vehicles (EVs) are currently ideal for what is wanted in the future of transport. However, the lack of infrastructure for these vehicles makes many potential users choose hybrid vehicles. This paper presents an analysis of the influence of hybrid vehicle engines and electric motors on their performance. Three engines with slightly different power levels and similar characteristics were considered for the configured models. Additionally, two electric motors with very different power levels, but a very close maximum continuous torque were used in our models. One was an induction motor and the other was a permanent magnet synchronous motor. The ADVISOR software was used for vehicle configuration and simulation. Series and parallel hybrid vehicles were considered. The main dynamic performances and the fuel consumption rates of the two driving cycles were compared for the configured models. Three conventional models with the same engines used in HEVs were also simulated for reference. The results highlight that, in the case of HEVs, the choice of a combination engine/electric motor is crucial for obtaining the best compromise between a dynamic performance and a low fuel consumption and, implicitly, a low negative impact on the environment.

1 June 2015
Verified
Conference Paper
Closed access
Olivian ChiverOlivian Chiver
Olivian Chiver
Liviu NeamtLiviu Neamt
Liviu Neamt
Oliviu MateiOliviu Matei
Oliviu Matei
This paper deals with sudden short-circuit transient regimes of a three-phase salient poles synchronous generator. The three-phase, two-phase and single-phase transient short-circuits of a synchronous generator with two pole pairs, 1500 rev/s, are studied analytically, by finite elements analysis (FEA) and experimentally. Analytic study was performed using Mathcad and FEA was performed using MagNet software from Infolytica. In order to record the transient currents a Fluke 435 apparatus was used in laboratory. Finally, the results obtained by the three methods are discussed.

1 October 2014
Verified
Conference Paper
Closed access
Liviu NeamtLiviu Neamt
Liviu Neamt
Olivian ChiverOlivian Chiver
Olivian Chiver
CBCristian Barz
Cristian Barz
CCCristinel Costea
Cristinel Costea
ZEZoltan Erdei
Zoltan Erdei
The paper presents some considerations about power system grounding based on analytical computation, Finite Element Analysis (FEA) combined with neural network. There are studied vertical rods buried on different depth in homogenous and double-layer soil. First, the analytical solutions are compared with the numerical results for certifying the FEA settings then, different configurations for electrodes in different soil structures were analyzed and the results were interpreted using neuronal network. This approach offer solutions for any configurations in less time than FEA alone.

1 May 2013
Verified
Conference Paper
Closed access
DPDumitru Pop
Dumitru Pop
Liviu NeamtLiviu Neamt
Liviu Neamt
RTRadu Tirnovan
Radu Tirnovan
DSDorin Sabou
Dorin Sabou
In this paper a miniature circuit breaker (MCB) is analyzed using a finite method analysis (FEA) software. Once the 3D model was implemented, a series of simulations were carried out in order to find out the forces that appear inside the electromechanical trip unit and what influences the plunger to trip faster. Also, the influence of the material nonlinearity is emphasized in order to understand the real behavior of the material in a specific applied magnetic field.

1 January 2017 in International Journal of Advanced Computer Science and Applications
Verified
Journal Article
Open access
PDF file
Liviu NeamtLiviu Neamt
Liviu Neamt
OMOliviu Matei
Oliviu Matei
Olivian ChiverOlivian Chiver
Olivian Chiver
Even in homogenous soil and for simple geometrical structure the analytical design of a grounding system is a complex and not very accurate procedure. Using Finite Element Analysis (FEA) it can perform a precise design for complex grounding systems but with important hardware resources and time consumption. This paper proposes a methodology for power system grounding design, directed to ensure the advantages of the FEA but without its disadvantages. This is realized by adding the function emulation using neural networks. The vertical rod, buried in inhomogeneous soil is the subject of this presentation. Consequently, the first step was to perform FEA for a large number of configurations: different types of vertical rods connected to the surface, buried at various depths in different double-layer soil structures. Then, the results have been interpreted through a multi-layer perceptron (MLP) with one hidden layer. A compromise between the number of inputs and precision have been tested, in order to define a minimum number of FEA required to obtain an acceptable grounding system design, i.e. a desired grounding resistance, for any combinations of the geometrical and material parameters. The validation of the methodology was done based on data reported in various research works.