Josep Ramon Lliso-Ferrando

Prof. Dr. Josep Ramon Lliso-Ferrando

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2022 in Ocean Engineering
Verified
Journal Article
Closed access
Josep Ramon Lliso-FerrandoJosep Ramon Lliso-Ferrando
Josep Ramon Lliso-Ferrando
IGIsabel Gasch
Isabel Gasch
AMAna Martínez-Ibernón
Ana Martínez-Ibernón
MVManuel Valcuende
Manuel Valcuende

26 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
MVManuel Valcuende
Manuel Valcuende
Josep Ramon Lliso-FerrandoJosep Ramon Lliso-Ferrando
Josep Ramon Lliso-Ferrando
Marta Roig FloresMarta Roig Flores
Marta Roig Flores
JGJosé Manuel Gandía-Romero
José Manuel Gandía-Romero
The aim of this experimental work was to study the porous structure of Ultra-High-Performance Fibre-Reinforced Concretes (UH) made with different fibre volume contents (0%, 1%, 2%) under several curing conditions (laboratory environment, 20 °C, 60 °C, 90 °C), comparing the results with those recorded for ordinary, high strength and very high strength concretes. Scanning electron microscopy, mercury intrusion porosimetry, thermogravimetry, water absorption and oxygen permeability tests were carried out. The results showed a low portlandite content in UH (in the order of 75% lower than in concrete C50) and a low degree of hydration, but they rise with curing temperature. These concretes have a very fine porous structure, with a high concentration of pores on the nanoscale level, below 0.05 µm. Their porosity accessible to water is consequently around 7-fold lower than in conventional (C30), 6-fold lower than in high-strength (C50) and 4-fold lower than in very high-strength (C90) concretes. Their oxygen permeability is at least one order of magnitude lower than in C90, two orders of magnitude lower than in C50 and three orders of magnitude lower than in C30. The percentage of added steel fibre does not affect the UH porous structure.

28 February 2023 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
Josep Ramon Lliso-FerrandoJosep Ramon Lliso-Ferrando
Josep Ramon Lliso-Ferrando
IGIsabel Gasch
Isabel Gasch
AMAna Martínez-Ibernón
Ana Martínez-Ibernón
MVManuel Valcuende
Manuel Valcuende
Chloride-induced rebar corrosion is one of the main causes of damage in reinforced concrete structures (RCS). Chloride attacks lead to depassivation creating pits, which can imply major losses of sections. The current generated at these spots (microcell) is contributed by the current produced between corroded and uncorroded areas (macrocell). The influence of both currents has been deeply investigated based on solution studies, which do not actually represent the behaviour of concrete-embedded elements. The studies about macrocell currents in solution are interesting to analyse this phenomenon quickly and simply. However, they must not be interpreted as the reality of RCS because this requires studies using rebars embedded in concrete. The performed experimental plan verified this fact. In addition, another objective of this study was to analyse the influence of concrete’s electrical resistance and the limiting effect of the cathode/anode surface (Cs/As) ratio on macrocell currents in solution and in concrete. For this study, specimens manufactured using concretes with different properties were used: standard concrete (SC), high-performance concrete (HPC), very high-performance concrete (VHPC) and ultra-high performance-fibre reinforced concrete (UHPFRC). The conclusions show how the Cs/As ratio plays a key role in regulating macrocell current intensity, but what really governs this phenomenon is concrete resistivity because it regulates the participation of a bigger or smaller cathode surface. The influence of this parameter as a limiting factor of macrocell currents is fundamental, especially in high resistivity concretes like VHPC and UHPFRC.

9 April 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Josep Ramon Lliso-FerrandoJosep Ramon Lliso-Ferrando
Josep Ramon Lliso-Ferrando
AAAlba Arenós-Barrachina
Alba Arenós-Barrachina
PBPablo Monzón Bello
Pablo Monzón Bello
MVManuel Valcuende
Manuel Valcuende
Over the past decade, global cement production has exceeded 4 billion tonnes annually. This process has a considerable environmental impact and is estimated to account for approximately 5% to 7% of the total annual CO2 emissions released into the atmosphere. To mitigate the environmental consequences of cement production, extensive research has been conducted on alternative materials that can partially replace cement in concrete manufacturing, thereby reducing its carbon footprint. This study explores the utilisation of recycled brick powder as a supplementary cementitious material in mortar production, with replacement levels ranging from 5% to 45%. In addition to evaluating their mechanical properties, such as flexural and compressive strength, this research investigates the durability of the newly developed mortars. The results indicate a reduction in porosity of up to 50% and an enhancement in chloride penetration resistance by up to fourfold when the substitution rate is between 35% and 40% compared with mortar without replacement. Although no improvements were observed in carbonation resistance, the new mixtures exhibited an increase in resistivity of up to ninefold.

25 September 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Josep Ramon Lliso-FerrandoJosep Ramon Lliso-Ferrando
Josep Ramon Lliso-Ferrando
JGJosé Manuel Gandía-Romero
José Manuel Gandía-Romero
JSJuan Soto
Juan Soto
MVManuel Valcuende
Manuel Valcuende
This work aims to study the corrosion performance of six concretes in the marine environment: three ordinary concretes (C30, C40 and C50); one high-performance concrete (C90); two ultra high-performance concretes, one without fibres (C150-NF) and another one with steel fibres (C150-F). To this end, porosity and chloride ingress resistance were analysed at different ages. Resistivity was also evaluated and the corrosion rate in the embedded rebars was monitored. The results showed that C30, C40 and C50 had porosity accessible to water percentages and capillary absorption values between six- and eight-fold higher than C90 and C150-NF and C150-F, respectively. Similar differences were obtained when oxygen permeability was analysed. Chloride ingress resistance in the ordinary concretes was estimated to be one-fold lower than in C90 and two-fold lower than in C150-NF and C150-F. Presence of fibres in C150-F increased the diffusion coefficient between 5% and 50% compared to C150-NF. Fibres also affected resistivity: C150-NF had values above 5500 Ωm, but the C150-F and C90 values were between 700 and 1000 Ωm and were one-fold higher than the ordinary concretes. After 3 years, the corrosion damage in the embedded rebars exposed to a marine environment was negligible in C90, C150-NF and C150-F (9.5, 6.2 and 3.5 mg mass loss), but with higher values (between 170.4 and 328.9 mg) for C3, C40 and C50. The results allow a framework to be established to make comparisons in future studies.

18 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AMAna Martínez-Ibernón
Ana Martínez-Ibernón
Josep Ramon Lliso-FerrandoJosep Ramon Lliso-Ferrando
Josep Ramon Lliso-Ferrando
JGJosé Manuel Gandía-Romero
José Manuel Gandía-Romero
JSJuan Soto
Juan Soto
The present work presents the results obtained with a stainless steel (SS) voltammetric sensor to detect variations in humidity (H2O) and oxygen (O2) availability in concretes. First, studies in solution were run by preparing several solutions to represent the different conditions that can be found in concrete pores. Second, the sensor’s response was studied by varying O2 availability by argon or synthetic air bubbling. Then concrete conditions with different degrees of carbonation were simulated using solutions with a pH between 13 and 8.45. After characterization in solution, a study by means of concrete samples with several water/cement ratios (0.6, 0.5 and 0.4) was performed, in which sensors were embedded and studied under different O2 and H2O saturation conditions. The obtained results revealed that with the voltagram, it is possible to evaluate O2 availability variation from the slopes of the lines identified logarithmically in the voltagram for the obtained cathodic sweeping. All the results obtained with the sensor were correlated/validated by standard assays to characterize porosity in hardened concretes.