Lorenzo Muraglia

Dr. Lorenzo Muraglia

Nuclear Medicine, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2024 in Cancers
Verified
Journal Article
Open access
PDF file
FMFrancesco Mattana
Francesco Mattana
LMLorenzo Muraglia
Lorenzo Muraglia
ABAntonio Barone
Antonio Barone
MCMarzia Colandrea
Marzia Colandrea
YSYasmina Saker
Yasmina Saker
Francesco CeciFrancesco Ceci
Francesco Ceci
In the last decades, the development of PET/CT radiopharmaceuticals, targeting the Prostate-Specific Membrane Antigen (PSMA), changed the management of prostate cancer (PCa) patients thanks to its higher diagnostic accuracy in comparison with conventional imaging both in staging and in recurrence. Alongside molecular imaging, PSMA was studied as a therapeutic agent targeted with various isotopes. In 2021, results from the VISION trial led to the Food and Drug Administration (FDA) approval of [177Lu]Lu-PSMA-617 as a novel therapy for metastatic castration-resistant prostate cancer (mCRPC) and set the basis for a radical change in the future perspectives of PCa treatment and the history of Nuclear Medicine. Despite these promising results, primary resistance in patients treated with single-agent [177Lu]Lu-PSMA-617 remains a real issue. Emerging trials are investigating the use of [177Lu]Lu-PSMA-617 in combination with other PCa therapies in order to cover the multiple oncologic resistance pathways and to overcome tumor heterogeneity. In this review, our aim is to retrace the history of PSMA-targeted therapy from the first preclinical studies to its future applications in PCa.

20 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
LMLorenzo Muraglia
Lorenzo Muraglia
FMFrancesco Mattana
Francesco Mattana
LTLaura Lavinia Travaini
Laura Lavinia Travaini
GMGennaro Musi
Gennaro Musi
Emilio BertaniEmilio Bertani
Emilio Bertani
Francesco CeciFrancesco Ceci
Francesco Ceci
Objective: to evaluate the feasibility of the intra-operative application of a specimen PET/CT imager in a clinical setting. Materials and methods: this is a pilot analysis performed in three patients who received an intra-operative administration of 68Ga-PSMA-11 (n = 2) and 68Ga-DOTA-TOC (n = 1), respectively. Patients were administrated with PET radiopharmaceuticals to perform radio-guided surgery with a beta-probe detector during radical prostatectomy for prostate cancer (PCa) and salvage lymphadenectomy for recurrent neuroendocrine tumor (NET) of the ileum, respectively. All procedures have been performed within two ongoing clinical trials in our Institute (NCT05596851 and NCT05448157). Pathologic assessment with immunohistochemistry (PSMA-staining and SSA immunoreactivity) was considered as standard of truth. Specimen images were compared with baseline PET/CT images and histopathological analysis. Results: Patients received 1 MBq/Kg of 68Ga-PSMA-11 (PCa) or 1.2 MBq/Kg of 68Ga-DOTA-TOC (NET) prior to surgery. Specimens were collected, positioned in the dedicated specimen container, and scanned to obtain high-resolution PET/CT images. In all cases, a perfect match was observed between the findings detected by the specimen imager and histopathology. Overall, the PET spatial resolution was sensibly higher for the specimen images compared to the baseline whole-body PET/CT images. Furthermore, the use of the PET/CT specimen imager did not significantly interfere with any procedures, and the overall length of the surgery was not affected using the PET/CT specimen imager. Finally, the radiation exposure of the operating theater staff was lower than 40 µSv per procedure (range 26–40 μSv). Conclusions: the image acquisition of specimens obtained by patients who received intra-surgery injections of 68Ga-PSMA-11 and 68Ga-DOTA-TOC was feasible and reliable also in a live-experience session and has been easily adapted to surgery daily practice. The high sensitivity, together with the evaluation of intra-lesion tumor heterogeneity, were the most relevant results since the data derived from specimen PET/CT imaging matched perfectly with the histopathological analysis.

10 February 2023 in Tomography
Verified
Journal Article
Open access
PDF file
LFLighea Simona Airò Farulla
Lighea Simona Airò Farulla
LTLaura Lavinia Travaini
Laura Lavinia Travaini
MCMariarosaria Cuomo
Mariarosaria Cuomo
DGDomenico Galetta
Domenico Galetta
FMFrancesco Mattana
Francesco Mattana
Francesco CeciFrancesco Ceci
Francesco Ceci
Renal Cell Carcinoma (RCC) is generally characterized by low-FDG avidity, and [18F]FDG-PET/CT is not recommended to stage the primary tumor. However, its role to assess metastases is still unclear. The aim of this study was to evaluate the diagnostic accuracy of [18F]FDG-PET/CT in correctly identifying RCC lung metastases using histology as the standard of truth. The records of 350 patients affected by RCC were retrospectively analyzed. The inclusion criteria were: (a) biopsy- or histologically proven RCC; (b) Computed Tomography (CT) evidence of at least one lung nodule; (c) [18F]FDG-PET/CT performed prior to lung surgery; (d) lung surgery with histological analysis of surgical specimens; (e) complete follow-up available. A per-lesion analysis was performed, and diagnostic accuracy was reported as sensitivity and specificity, using histology as the standard of truth. [18F]FDG-PET/CT semiquantitative parameters (Standardized Uptake Value [SUVmax], Metabolic Tumor Volume [MTV] and Total Lesion Glycolysis [TLG]) were collected for each lesion. Sixty-seven patients with a total of 107 lesions were included: lung metastases from RCC were detected in 57 cases (53.3%), while 50 lesions (46.7%) were related to other lung malignancies. Applying a cut-off of SUVmax ≥ 2, the sensitivity and the specificity of [18F]FDG-PET/CT in detecting RCC lung metastases were 33.3% (95% CI: 21.4–47.1%) and 26% (95%CI: 14.6–40.3%), respectively. Although the analysis demonstrated a suboptimal diagnostic accuracy of [18F]FDG-PET/CT in discriminating between lung metastases from RCC and other malignancies, a semiquantitative analysis that also includes volumetric parameters (MTV and TLG) could support the correct interpretation of [18F]FDG-PET/CT images.

1 June 2024 in The Quarterly Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
LMLorenzo Muraglia
Lorenzo Muraglia
ELEgesta Lopci
Egesta Lopci
JJJelena Jandric
Jelena Jandric
RZRoberta Zanca
Roberta Zanca
MRMarcello Rodari
Marcello Rodari
LELaura Evangelista
Laura Evangelista
Article: Prostate cancer: nuclear medicine imaging in the biochemical recurrence and in oligometastatic disease - The Quarterly Journal of Nuclear Medicine and Molecular Imaging 2024 June;68(2):95-100 - Minerva Medica - Journals

2 February 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
LMLorenzo Muraglia
Lorenzo Muraglia
FMFrancesco Mattana
Francesco Mattana
LTLaura Lavinia Travaini
Laura Lavinia Travaini
GMGennaro Musi
Gennaro Musi
Emilio BertaniEmilio Bertani
Emilio Bertani
Francesco CeciFrancesco Ceci
Francesco Ceci
Objective: to evaluate the feasibility of the intra-operative application of a specimen PET/CT imager in a clinical setting. Materials and methods: this is a pilot analysis performed in three patients who received an intra-operative administration of 68Ga-PSMA-11 (n=2) and 68Ga-DOTA-TOC (n=1), respectively. Patients were administrated with PET radiopharmaceuticals to perform radio-guided surgery with a beta-probe detector during radical prostatectomy for prostate cancer (PCa) and salvage lymphadenectomy for recurrent neuroendocrine tumor (NET) of the ileum, respectively. All procedures have been performed within two ongoing clinical trials in our Institute (NCT05596851 and NCT05448157). Pathologic assessment with immunohistochemistry (PSMA-staining and SSA immunoreactivity) was considered as standard of truth. Specimen images were compared with baseline PET/CT images and histopathological analysis. Results: Patients received 1 MBq/Kg of 68Ga-PSMA-11 (PCa) or 1.2 MBq/Kg of 68Ga-DOTA-TOC (NET) prior to surgery. Specimens were collected, positioned in the dedicated specimen container, and scanned to obtain high resolution PET/CT images. In all cases a perfect match was observed between the findings detected by the specimen imager and histopathology. Overall, the PET spatial resolution was sensibly higher for the specimen images compared to the baseline whole-body PET/CT images. Furthermore, the use of the PET/CT specimen imager did not significantly interfere with any procedures, and the overall length of the surgery was not affected using the PET/CT specimen imager. Finally, the radiation exposure of the operating theater staff was lower than 40 µSv per procedure (range 26 – 40 Sv). Conclusion: the image acquisition of specimens obtained by patients who received intra-surgery injection of 68Ga-PSMA-11 and 68Ga-DOTA-TOC was feasible and reliable also in a live-experience session and has been easily adapted to surgery daily-practice. The high sensitivity, together with the evaluation of intra-lesion tumor heterogeneity, were the most relevant results since the data derived from specimen PET/CT imaging matched perfectly with the histopathological analysis.

4 January 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
LFLighea Simona Airò Farulla
Lighea Simona Airò Farulla
LTLaura Lavinia Travaini
Laura Lavinia Travaini
MCMariarosaria Cuomo
Mariarosaria Cuomo
DGDomenico Galetta
Domenico Galetta
FMFrancesco Mattana
Francesco Mattana
Francesco CeciFrancesco Ceci
Francesco Ceci
Renal Cell Carcinoma (RCC) is generally represented by low-FDG avidity, and [18F]FDG-PET/CT is not recommended to stage the primary tumor. However, its role to assess metastases is still unclear. The aim of this study was to evaluate the diagnostic accuracy of [18F]FDG-PET/CT to correctly identify RCC lung metastases using histology as standard of truth. Records of 350 patients affected by RCC and with CT evidence of at least one lung nodule, were retrospectively analyzed. Inclusion criteria were: a) histologically proven RCC; b) [18F]FDG-PET/CT performed prior to lung surgery; c) lung surgery with histological analysis of surgical specimens; d) complete follow-up available. A per-lesion analysis was performed, and diagnostic accuracy was reported as sensitivity and specificity, using histology as standard of truth. [18F]FDG-PET/CT semiquantitative parameters (Standardized Uptake Value [SUVmax], Metabolic Tumor Volume [MTV] and Total Lesion Glycolysis [TLG]) were collected for each lesion. Sixty-seven (n=67) patients with a total of 107 lesions were included: lung metastases from RCC were detected in 57/107 of cases, while 50/107 lesions were related to others lung malignancies. Applying a cut-off of SUVmax ≥2, the sensitivity and the specificity of [18F]FDG-PET/CT for detect RCC lung metastases were 33.3% (95% CI: 21.4% - 47.1%) and 26% (95%CI: 14.6% - 40.3%), respectively. The analysis demonstrated sub-optimal diagnostic accuracy of [18F]FDG-PET/CT to discriminate between RCC lung metastases versus other malignancies. However, semiquantitative analysis including also volumetric parameters (MTV and TLG) can support [18F]FDG-PET/CT image interpretation.