Luciano Coutinho Gomes

Prof. Luciano Coutinho Gomes

Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Electric Power Systems Research
Verified
Journal Article
Closed access
GVG.P. Viajante
G.P. Viajante
DAD.A. Andrade
D.A. Andrade
ECE.N. Chaves
E.N. Chaves
VBV.R. Bernadelli
V.R. Bernadelli
CQC.A. Queiroz
C.A. Queiroz
Luciano Coutinho GomesLuciano Coutinho Gomes
Luciano Coutinho Gomes

4 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
Gustavo de Oliveira MachadoGustavo de Oliveira Machado
Gustavo de Oliveira Machado
Luciano Coutinho GomesLuciano Coutinho Gomes
Luciano Coutinho Gomes
ASAugusto Wohlgemuth Fleury Veloso da Silveira
Augusto Wohlgemuth Fleury Veloso da Silveira
CTCarlos Eduardo Tavares
Carlos Eduardo Tavares
DADarizon Alves de Andrade
Darizon Alves de Andrade
The monitoring of partial discharges (PDs) is one of the main methods used worldwide for evaluation and diagnosis of the insulation conditions in equipment powered by medium and high voltages. The occurrence of PDs is usually an indication of the appearance of insulation defects, which over time can compromise the dielectric withstand of the material used, increasing the probability of complete breakdown. In general, laboratory tests for detecting and registering PDs are carried out using purely sinusoidal voltages. However, it is very common for an electrical asset to be subjected at some point in its operating life to voltages distorted by harmonic components. Some studies reported in the literature reveal that harmonic distortions can affect the PDs’ characteristics, nevertheless, the effects of individual harmonic components on PDs still need to be analyzed. In this context, this paper proposes to evaluate the impacts of harmonic voltage distortions on the dynamic behavior and the phase-resolved partial discharge (PRPD) patterns of PDs in an air cavity within a solid dielectric material. For this, a simulation model was implemented, which was used to analyze the effects of applying distorted voltages composed of different harmonic orders (third, fifth, and seventh) and distinct levels of distortion (1%, 3%, 5%, 10%, 15%, and 20%). In addition, the influence of the third harmonic phase angle on PDs is also analyzed. The results extracted from the simulations revealed that the harmonic distortions caused changes in the numbers of PDs per cycle, in the mean apparent charges of the PDs per cycle, and in the PRPD patterns’ characteristics. These changes were very significant for higher distortion levels, which in practice may impair the interpretation of PD measurement records for the diagnosis of the condition of the insulation system.

10 November 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
GVGhunter Paulo Viajante
Ghunter Paulo Viajante
ECEric Nery Chaves
Eric Nery Chaves
LMLuis Carlos Miranda
Luis Carlos Miranda
MFMarcos Antonio A. de Freitas
Marcos Antonio A. de Freitas
CQCarlos Antunes de Queiroz
Carlos Antunes de Queiroz
RFRicardo Tirone Fidelis
Ricardo Tirone Fidelis
This paper presents an experimental methodology to control the voltage generated from a Switched Reluctance Generator (SRG) using Fuzzy Logic Control. The generated voltage is controlled by varying the demagnetization angle (θoff), maintaining fixed the magnetization angle (θon). The developed strategy operates on the upper switches of the asymmetric half-bridge converter. The converter topology is used in conjunction with an intermediate freewheeling stage between the steps of magnetization and demagnetization of the phases. The control algorithm was developed in a DSP/FPGA with high processing capacity using LabVIEW graphical platform. Results in open loop and closed loop are presented subjecting the switched reluctance generator to variable speeds and load application. For the purpose of performance comparison, a PI compensator has been implemented and tuned for this specific application and the results for both controllers are presented and discussed. For the open loop tests, the SRG was subjected to variations in the rotor speed, namely: shaft speed varying sinusoidally and triangularly. In these tests, it was observed that the bus voltage suffered great variations. Load variations were also implemented in open loop and, once again, the bus voltage varied significantly. In laboratory tests in closed loop, the SRG was again subjected to variations in sinusoidal and triangular speed and still under load step. In all these experiments, comparisons of results were made between PI controllers and using Fuzzy Logic Control. At the end, it was observed that the imposition of a control loop allowed the bus voltage to be maintained at the pre-established value.

10 October 2020
Verified
Conference Paper
Closed access
CSCaio Eduardo Silva
Caio Eduardo Silva
HPHelder de Paula
Helder de Paula
FDFrancisco de Assis Dias
Francisco de Assis Dias
Luciano Coutinho GomesLuciano Coutinho Gomes
Luciano Coutinho Gomes
Specially in the mining, steelmaking and oil industries, Pulse Width Modulation Voltage Source Inverters (PWM-VSI) driving induction motors located far away are often present. In this case, due to the long cable used for the converter-to-motor connection, several unwanted high-frequency phenomena are generated. In this context, a new configuration for drive systems was proposed, in which the rectifier is kept in its original position and the inverter bridge is installed near the driven motor, whose environment is always more hostile and can compromise its lifetime. In spite of the various technical-economic advantages from this new configuration, new concerns regarding the system reliability arise. In this way, the aim of the present study is to discuss, in a qualitative way, the main stressors present in typical motor drive applications, the dominant failure mechanisms of the critical components and the potential problems resulting from the inverter installation in harsh environments, along with the possible solutions to reduce them.

7 June 2021 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
WVWagner Eduardo Vanço
Wagner Eduardo Vanço
FSFernando Silva
Fernando Silva
JMJosé Roberto Boffino de Almeida Monteiro
José Roberto Boffino de Almeida Monteiro
COCarlos Matheus R. de Oliveira
Carlos Matheus R. de Oliveira
Luciano Coutinho GomesLuciano Coutinho Gomes
Luciano Coutinho Gomes
This work presents a theoretical-experimental study in permanent regime of the three-phase induction generator of squirrel cage connected directly to the distribution network at fixed speed. The study is based on the operation of the induction generator that operates with the capacitor bank and without the presence of the capacitor bank to show the improvement of the power factor of the induction generator when in connection with the electric distribution network.

1 June 2017
Verified
Conference Paper
Closed access
GVG. P. Viajante
G. P. Viajante
ECE. N. Chaves
E. N. Chaves
CQC. A. Queiroz
C. A. Queiroz
MFM. A. A. Freitas
M. A. A. Freitas
LML. C. Miranda
L. C. Miranda
RFR. T. Fidelis
R. T. Fidelis
This paper presents a scheme to connect the SRG to the single-phase power grid for active power injection. A voltage control scheme of the SRG using a PI compensator to adjust the magnetization angles of the generator phases will be shown. The SRG is subjected to variable speed operation to verify the control effectiveness. A description of the P+RES compensator employed as an alternative to the PI compensator for current injection control will presented. The electric network synchronization is obtained through a PLL algorithm. The simulation and experimental results are presented proving the SRG suitable operation working at variable speed and connected to the electric grid for active power injection.