Maciej Maciak

Dr. Maciej Maciak

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Radiation Measurements
Verified
Journal Article
Open access
IAIva Ambrožová
Iva Ambrožová
PBPeter Beck
Peter Beck
EBEric R. Benton
Eric R. Benton
RBRobert Billnert
Robert Billnert
JBJean-Francois Bottollier-Depois
Jean-Francois Bottollier-Depois
OPOndřej Ploc
Ondřej Ploc

30 October 2024 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
DJDaria Jozwiak-Niedzwiedzka
Daria Jozwiak-Niedzwiedzka
PRPavel Rovnaník
Pavel Rovnaník
MDMariusz Dąbrowski
Mariusz Dąbrowski
JOJakub Ośko
Jakub Ośko
MKMichał Kuć
Michał Kuć
MMMaciej Maciak
Maciej Maciak

1 June 2016 in Polish Journal of Medical Physics And Engineering
Verified
Journal Article
Open access
PDF file
SDSzymon Domański
Szymon Domański
MGMichał A. Gryziński
Michał A. Gryziński
MMMaciej Maciak
Maciej Maciak
ŁMŁukasz Murawski
Łukasz Murawski
PTPiotr Tulik
Piotr Tulik
KTKatarzyna Tymińska
Katarzyna Tymińska
This paper presents the set of procedures developed in Radiation Protection Measurements Laboratory at National Centre for Nuclear Research for evaluation of shielding properties of high performance concrete. The purpose of such procedure is to characterize the material behaviour against gamma and neutron radiation. The range of the densities of the concrete specimens was from 2300 to 3900 kg/m3. The shielding properties against photons were evaluated using 137Cs and 60Co sources. The neutron radiation measurements have been performed by measuring the transmitted radiation from 239PuBe source. Scattered neutron radiation has been evaluated using the shadow cone technique. A set up of ionization chambers was used during all experiments. The gamma dose was measured using C-CO2 ionization chamber. The neutron dose was evaluated with recombination chamber of REM-2 type with appropriate recombination method applied. The method to distinguish gamma and neutron absorbed dose components in mixed radiation fields using twin detector method was presented. Also, recombination microdosimetric method was applied for the obtained results. Procedures to establish consecutive half value layers and tenth value layers (HVL and TVL) for gamma and neutron radiation were presented. Measured HVL and TVL values were linked with concrete density to highlight well known dependence. Also, influence of specific admixtures to concrete on neutron attenuation properties was studied. The results confirmed the feasibility of approach for the radiation shielding investigations.

29 September 2017 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
PTPiotr Tulik
Piotr Tulik
MTMonika Tulik
Monika Tulik
MMMaciej Maciak
Maciej Maciak
NGNatalia Golnik
Natalia Golnik
DKDamian Kabat
Damian Kabat
JLJan Lesiak
Jan Lesiak
The aim of this study is to investigate secondary mixed radiation field around linac, as the first part of an overall assessment of out-of-field contribution of neutron dose for new advanced radiation dose delivery techniques. All measurements were performed around Varian Clinic 2300 C/D accelerator at Maria Sklodowska-Curie Memorial, Cancer Center and Institute of Oncology, Krakow Branch. Recombination chambers REM-2 and GW2 were used for recombination index of radiation quality Q4 determination (as an estimate of quality factor Q), measurement of total tissue dose Dt and calculation of gamma and neutron components to Dt. Estimation of Dt and Q4 allowed for the ambient dose equivalent H*(10) per monitor unit (MU) calculations. Measurements around linac were performed on the height of the middle of the linac’s head (three positions) and on the height of the linac’s isocentre (five positions). Estimation of secondary radiation level was carried out for seven different configurations of upper and lower jaws position and multileaf collimator set open or closed in each position. Study includes the use of two photon beam modes: 6 and 18 MV. Spatial distribution of ambient dose equivalent H*(10) per MU on the height of the linac’s head and on the standard couch height for patients during the routine treatment, as well as relative contribution of gamma and neutron secondary radiation inside treatment room were evaluated.

14 September 2022 in Radiation Physics and Chemistry
Verified
Journal Article
Open access
MMMaciej Maciak
Maciej Maciak
MKMarcin Konior
Marcin Konior
DWDanuta Wawszczak
Danuta Wawszczak
AMAleksandra Majewska
Aleksandra Majewska
KBKlaudia K. Brodaczewska
Klaudia K. Brodaczewska
EIEdward Iller
Edward Iller

1 December 2015 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
MGM.A. Gryziński
M.A. Gryziński
MMMaciej Maciak
Maciej Maciak
MWM. Wielgosz
M. Wielgosz