M. MAHABUBUR RAHMAN

Dr. M. MAHABUBUR RAHMAN

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
MRM. MAHABUBUR RAHMAN
M. MAHABUBUR RAHMAN
MUM. Jalal Uddin
M. Jalal Uddin
JHJun H. Hong
Jun H. Hong
NBNabil H. Bhuiyan
Nabil H. Bhuiyan
JSJoon S. Shim
Joon S. Shim

6 September 2024 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
MRM. MAHABUBUR RAHMAN
M. MAHABUBUR RAHMAN
BSBappa Sarkar
Bappa Sarkar
TRTareq Rahman
Tareq Rahman
GJGyeong J. Jin
Gyeong J. Jin
MUM. Jalal Uddin
M. Jalal Uddin
JSJoon S. Shim
Joon S. Shim
The blood-based detection of Alzheimer's disease (AD) is becoming challenging since the blood–brain barrier (BBB) restricts the direct circulation of AD molecules in the blood, thereby precluding the detection of AD at an early-stage. Herein, we report the development of a novel CNT-metal-porous graphene hybrid (CNT-MGH) nano-interdigitated array (n-IDA) electrochemical 8-well biosensor for the successful early-stage diagnosis of AD from blood. Laser-induced graphene (LIG) technology has been used to fabricate the proposed CNT-MGH n-IDA 8-well sensor. Firstly, the electrochemical characterization (i.e., electrode gap, material composition, etc.) of the proposed sensor was demonstrated by measuring p-aminophenol (PAP) with a limit of detection (LOD) of 0.1 picomole. Subsequently, the CNT-MGH n-IDA 8-well sensor was then used to diagnose AD via novel blood biomarkers p-Tau 217 and p-Tau 181 using an electrochemical enzyme-linked immunosorbent assay (e-ELISA) enzyme by-product PAP. During e-ELISA, the alkaline phosphatase enzyme (IgG-AP) tagged to the detection antibody produced an electroactive ELISA by-product PAP by reacting with the enzyme–substrate 4-aminophenyl phosphate (PAPP). Finally, the CNT-MGH n-IDA 8-well sensor was then used to measure the current generated by the redox reaction via the e-ELISA by-product PAP. While quantified, the proposed CNT-MGH n-IDA 8-well sensor successfully detected p-Tau 217 and p-Tau 181 proteins in blood with LODs of 0.16 pg ml−1 and 0.08 pg ml−1, respectively.

11 November 2024 in Journal of Power Sources
Verified
Journal Article
Closed access
MRM. MAHABUBUR RAHMAN
M. MAHABUBUR RAHMAN
TRTareq Rahman
Tareq Rahman
SHSarwar Hossen
Sarwar Hossen
BSBappa Sarkar
Bappa Sarkar
SLSoon Chang Lee
Soon Chang Lee
JSJoon S. Shim
Joon S. Shim

6 November 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MRM. MAHABUBUR RAHMAN
M. MAHABUBUR RAHMAN
NBNabil H. Bhuiyan
Nabil H. Bhuiyan
MPMinJun Park
MinJun Park
MUM. Jalal Uddin
M. Jalal Uddin
GJGyeong J. Jin
Gyeong J. Jin
JSJoon S. Shim
Joon S. Shim

2 June 2025 in Journal of Power Sources
Verified
Journal Article
Closed access
MRM. MAHABUBUR RAHMAN
M. MAHABUBUR RAHMAN
SHSarwar Hossen
Sarwar Hossen
BSBappa Sarkar
Bappa Sarkar
TRTareq Rahman
Tareq Rahman
SLSoon Chang Lee
Soon Chang Lee
JSJoon S. Shim
Joon S. Shim

3 July 2024 in Small Methods
Verified
Journal Article
Open access
TRTareq Rahman
Tareq Rahman
SHSarwar Hossen
Sarwar Hossen
KJKyoung‐Jin Jeong
Kyoung‐Jin Jeong
NBNabil H. Bhuiyan
Nabil H. Bhuiyan
MRM. MAHABUBUR RAHMAN
M. MAHABUBUR RAHMAN
JSJoon S. Shim
Joon S. Shim
The increasing demand for electric vehicles necessitates the development of cost‐effective, mass‐producible, long‐lasting, and highly conductive batteries. Making this kind of battery is exceedingly tricky. This study introduces an innovative fabrication technique utilizing a laser‐induced graphene (LIG) approach on commercial Kapton film to create hexagonal pores. These pores form vertical conduction paths for electron and ion transportation during lithiation and delithiation, significantly enhancing conductivity. The nongraphitized portion of the Kapton film makes it a binder‐less, free‐standing electrode, providing mechanical stability. Various analytical techniques, including scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), Raman spectroscopy, and atomic force microscopy (AFM) are utilized to confirm the transformation of a 3D porous graphene sheet from a commercial Kapton film. Cross‐sectional SEM images verify the vertical connections. The specific capacity of 581 mAh g−1 is maintained until the end, with 99% coulombic efficiency at 0.1C. This simple manufacturing method paves the pathway for future LIG‐based, cost‐effective, lightweight, mass‐producible, long‐lasting, vertically conductive electrodes for lithium‐ion batteries.