Ioannis Mandilaras

Dr. Ioannis Mandilaras

National Technical University of Athens
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2009 in Cement and Concrete Composites
Verified
Journal Article
Closed access
MHM. Hunger
M. Hunger
AEA.G. Entrop
A.G. Entrop
IMIoannis Mandilaras
Ioannis Mandilaras
HBH.J.H. Brouwers
H.J.H. Brouwers
Maria FountiMaria Founti
Maria Founti

1 September 2013 in Energy and Buildings
Verified
Journal Article
Closed access
DKDionysios Kolaitis
Dionysios Kolaitis
EMEmmanouil Malliotakis
Emmanouil Malliotakis
DKDimos Kontogeorgos
Dimos Kontogeorgos
IMIoannis Mandilaras
Ioannis Mandilaras
DKDimitrios I. Katsourinis
Dimitrios I. Katsourinis
Maria FountiMaria Founti
Maria Founti

1 March 2013 in Building and Environment
Verified
Journal Article
Closed access
IMIoannis Mandilaras
Ioannis Mandilaras
MSM. Stamatiadou
M. Stamatiadou
DKD. Katsourinis
D. Katsourinis
GZG. Zannis
G. Zannis
Maria FountiMaria Founti
Maria Founti

1 December 2014 in Energy and Buildings
Verified
Journal Article
Closed access
IMIoannis Mandilaras
Ioannis Mandilaras
IAI. Atsonios
I. Atsonios
GZG. Zannis
G. Zannis
Maria FountiMaria Founti
Maria Founti


11 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
MDMichaela Detsi
Michaela Detsi
AMAris Manolitsis
Aris Manolitsis
IAIoannis Atsonios
Ioannis Atsonios
IMIoannis Mandilaras
Ioannis Mandilaras
Maria FountiMaria Founti
Maria Founti
This paper assesses energy savings in terms of heating, cooling, and artificial lighting achieved in an office building with a high Window to Wall Ratio (WWR), located in Athens and Stockholm. Six different configurations of triple pane windows combining thermochromic, electrochromic, and low-e coatings in Insulated Glass Units (IGUs) are examined to quantify the potential of increasing energy savings in office buildings. The combination of electrochromic and thermochromic layers on the outer pane of the triple IGU, achieved an 18.5% and 8.1% reduction in annual primary energy use for Athens and Stockholm, respectively. The used switching strategy ensured the visual comfort of the employees and provided adequate daylight in both cases. It was found that in Stockholm the cooling system can be downsized considerably, achieving important cost reduction in the HVAC system. The analysis also takes into account the reduction of thermal storage in the building envelope due to the switchable windows. This reduction is beneficial in the case of Athens, but it can reduce energy savings in Stockholm. Therefore, for colder climates, it is important to increase window heat gains through the development of layers with higher g-value in the clear state and through the application of appropriate switching strategies.