Manuel Andrés Vélez-Guerrero

Prof. Dr. Manuel Andrés Vélez-Guerrero

Universidad Pedagógica y Tecnológica de Colombia, Tunja, Boyacá, Colombia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Manuel Andrés Vélez-GuerreroManuel Andrés Vélez-Guerrero
Manuel Andrés Vélez-Guerrero
Mauro Callejas-CuervoMauro Callejas-Cuervo
Mauro Callejas-Cuervo
Stefano MazzoleniStefano Mazzoleni
Stefano Mazzoleni
Processing and control systems based on artificial intelligence (AI) have progressively improved mobile robotic exoskeletons used in upper-limb motor rehabilitation. This systematic review presents the advances and trends of those technologies. A literature search was performed in Scopus, IEEE Xplore, Web of Science, and PubMed using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) methodology with three main inclusion criteria: (a) motor or neuromotor rehabilitation for upper limbs, (b) mobile robotic exoskeletons, and (c) AI. The period under investigation spanned from 2016 to 2020, resulting in 30 articles that met the criteria. The literature showed the use of artificial neural networks (40%), adaptive algorithms (20%), and other mixed AI techniques (40%). Additionally, it was found that in only 16% of the articles, developments focused on neuromotor rehabilitation. The main trend in the research is the development of wearable robotic exoskeletons (53%) and the fusion of data collected from multiple sensors that enrich the training of intelligent algorithms. There is a latent need to develop more reliable systems through clinical validation and improvement of technical characteristics, such as weight/dimensions of devices, in order to have positive impacts on the rehabilitation process and improve the interactions among patients, teams of health professionals, and technology.

10 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Manuel Andrés Vélez-GuerreroManuel Andrés Vélez-Guerrero
Manuel Andrés Vélez-Guerrero
Mauro Callejas-CuervoMauro Callejas-Cuervo
Mauro Callejas-Cuervo
Stefano MazzoleniStefano Mazzoleni
Stefano Mazzoleni
Neuromotor rehabilitation and recovery of upper limb functions are essential to improve the life quality of patients who have suffered injuries or have pathological sequels, where it is desirable to enhance the development of activities of daily living (ADLs). Modern approaches such as robotic-assisted rehabilitation provide decisive factors for effective motor recovery, such as objective assessment of the progress of the patient and the potential for the implementation of personalized training plans. This paper focuses on the design, development, and preliminary testing of a wearable robotic exoskeleton prototype with autonomous Artificial Intelligence-based control, processing, and safety algorithms that are fully embedded in the device. The proposed exoskeleton is a 1-DoF system that allows flexion-extension at the elbow joint, where the chosen materials render it compact. Different operation modes are supported by a hierarchical control strategy, allowing operation in autonomous mode, remote control mode, or in a leader-follower mode. Laboratory tests validate the proper operation of the integrated technologies, highlighting a low latency and reasonable accuracy. The experimental result shows that the device can be suitable for use in providing support for diagnostic and rehabilitation processes of neuromotor functions, although optimizations and rigorous clinical validation are required beforehand.

24 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LMLaura Alejandra Espitia Mora
Laura Alejandra Espitia Mora
Manuel Andrés Vélez-GuerreroManuel Andrés Vélez-Guerrero
Manuel Andrés Vélez-Guerrero
Mauro Callejas-CuervoMauro Callejas-Cuervo
Mauro Callejas-Cuervo
Technological advancements have expanded the range of methods for capturing human body motion, including solutions involving inertial sensors (IMUs) and optical alternatives. However, the rising complexity and costs associated with commercial solutions have prompted the exploration of more cost-effective alternatives. This paper presents a markerless optical motion capture system using a RealSense depth camera and intelligent computer vision algorithms. It facilitates precise posture assessment, the real-time calculation of joint angles, and acquisition of subject-specific anthropometric data for gait analysis. The proposed system stands out for its simplicity and affordability in comparison to complex commercial solutions. The gathered data are stored in comma-separated value (CSV) files, simplifying subsequent analysis and data mining. Preliminary tests, conducted in controlled laboratory environments and employing a commercial MEMS-IMU system as a reference, revealed a maximum relative error of 7.6% in anthropometric measurements, with a maximum absolute error of 4.67 cm at average height. Stride length measurements showed a maximum relative error of 11.2%. Static joint angle tests had a maximum average error of 10.2%, while dynamic joint angle tests showed a maximum average error of 9.06%. The proposed optical system offers sufficient accuracy for potential application in areas such as rehabilitation, sports analysis, and entertainment.

13 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Sonia Rocio Moreno CastelblancoSonia Rocio Moreno Castelblanco
Sonia Rocio Moreno Castelblanco
Manuel Andrés Vélez-GuerreroManuel Andrés Vélez-Guerrero
Manuel Andrés Vélez-Guerrero
Mauro Callejas-CuervoMauro Callejas-Cuervo
Mauro Callejas-Cuervo
Background: Motor imagery (MI) is defined as the cognitive ability to simulate motor movements while suppressing muscular activity. The electroencephalographic (EEG) signals associated with lower limb MI have become essential in brain–computer interface (BCI) research aimed at assisting individuals with motor disabilities. Objective: This systematic review aims to evaluate methodologies for acquiring and processing EEG signals within brain–computer interface (BCI) applications to accurately identify lower limb MI. Methods: A systematic search in Scopus and IEEE Xplore identified 287 records on EEG-based lower-limb MI using artificial intelligence. Following PRISMA guidelines (non-registered), 35 studies met the inclusion criteria after screening and full-text review. Results: Among the selected studies, 85% applied machine or deep learning classifiers such as SVM, CNN, and LSTM, while 65% incorporated multimodal fusion strategies, and 50% implemented decomposition algorithms. These methods improved classification accuracy, signal interpretability, and real-time application potential. Nonetheless, methodological variability and a lack of standardization persist across studies, posing barriers to clinical implementation. Conclusions: AI-based EEG analysis effectively decodes lower-limb motor imagery. Future efforts should focus on harmonizing methods, standardizing datasets, and developing portable systems to improve neurorehabilitation outcomes. This review provides a foundation for advancing MI-based BCIs.

20 November 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
FPFrancisco David Parra
Francisco David Parra
Manuel Andrés Vélez-GuerreroManuel Andrés Vélez-Guerrero
Manuel Andrés Vélez-Guerrero
Mauro Callejas-CuervoMauro Callejas-Cuervo
Mauro Callejas-Cuervo
For both human health and the environment, air pollution is a serious concern. However, the available air quality monitoring networks have important limitations, such as the high implementation costs, limited portability, and considerable operational complexity. In this context, unmanned aerial systems (UASs) are emerging as a useful technological alternative due to their ability to cover large distances and access areas that are difficult or impossible for humans to reach. This article presents the development of an integrated platform that combines an unmanned aerial system (UAS) with specialized sensors to measure key parameters in relation to air quality, such as carbon monoxide (CO), ozone (O3), and nitrogen dioxide (NO2). In addition, a web application called PTECA is developed to visualize the data gathered by the wireless sensor array in real time. The platform incorporates a system that allows real-time tracking of the UAS route and measurement values during sample collection, employing the LoRa communication protocol. This solution represents a low-cost alternative that mitigates some of the limitations of traditional monitoring networks by offering greater portability and accessibility in terms of data collection. Preliminary tests successfully demonstrate the viability of the proposed system in a controlled airspace using geofencing.

25 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Manuel Andrés Vélez-GuerreroManuel Andrés Vélez-Guerrero
Manuel Andrés Vélez-Guerrero
Mauro Callejas-CuervoMauro Callejas-Cuervo
Mauro Callejas-Cuervo
Juan Carlos AlvarezJuan Carlos Alvarez
Juan Carlos Alvarez
Stefano MazzoleniStefano Mazzoleni
Stefano Mazzoleni
Robotic exoskeletons are active devices that assist or counteract the movements of the body limbs in a variety of tasks, including in industrial environments or rehabilitation processes. With the introduction of textile and soft materials in these devices, the effective motion transmission, mechanical support of the limbs, and resistance to physical disturbances are some of the most desirable structural features. This paper proposes an evaluation protocol and assesses the mechanical support properties of a servo-controlled robotic exoskeleton prototype for rehabilitation in upper limbs. Since this prototype was built from soft materials, it is necessary to evaluate the mechanical behavior in the areas that support the arm. Some of the rehabilitation-supporting movements such as elbow flexion and extension, as well as increased muscle tone (spasticity), are emulated. Measurements are taken using the reference supplied to the system’s control stage and then compared with an external high-precision optical tracking system. As a result, it is evidenced that the use of soft materials provides satisfactory outcomes in the motion transfer and support to the limb. In addition, this study lays the groundwork for a future assessment of the prototype in a controlled laboratory environment using human test subjects.