OBJECTIVE: To use the advantages of a ratio scale with verbal anchors in order to measure the risk perception in the novel coronavirus infection, which causes covid-19, in a health belief model-based questionnaire, as well as its validity and reproducibility. METHOD: We used the health belief model, which explores four dimensions: perceived susceptibility (five questions), perceived severity (five questions), perceived benefits (five questions), and perceived barriers (five questions). Additionally, we included a fifth dimension, called pro-health motivation (four questions). The questions composed an electronic questionnaire disseminated by social networks for an one-week period. Answers were quantitative values of subjective representations, obtained by a psychophysically constructed scale with verbal anchors ratio (CentiMax®). Mean time for total filling was 12 minutes (standard deviation = 1.6). RESULTS: We obtained 277 complete responses to the form. One was excluded because it belonged to a participant under 18 years old. Reproducibility measures were significant for 22 of the 24 questions in our questionnaire (Cronbach’s α = 0.883). Convergent validity was attested by Spearman-Brown’s split half reliability coefficient (r = 0.882). Significant differences among groups were more intense in perceived susceptibility and severity dimensions, and less in perceived benefits and barriers. CONCLUSION: Our health belief model-based questionnaire using quantitative measures enabled the confirmation of popular beliefs about covid-19 infection risks. The advantage in our approach lays in the possibility of quickly, directly and quantitatively identifying individual belief profiles for each dimension in the questionnaire, serving as a great ally for communication processes and public health education.
25 August 2010 in Ophthalmic and Physiological Optics
We evaluated the color vision of mercury-contaminated patients and investigated possible retinal origins of losses using electroretinography. Participants were retired workers from a fluorescent lamp industry diagnosed with mercury contamination (n= 43) and age-matched controls (n= 21). Color discrimination was assessed with the Cambridge Colour Test (CCT). Retinal function was evaluated by using the ISCEV protocol for full-field electroretinography (full-field ERG), as well as by means of multifocal electroretinography (mfERG). Color-vision losses assessed by the CCT consisted of higher color-discrimination thresholds along the protan, deutan, and tritan axes and significantly larger discrimination ellipses in mercury-exposed patients compared to controls. Full-field ERG amplitudes from patients were smaller than those of the controls for the scotopic responseb-wave, maximum response, sum of oscillatory potentials (OPs), 30-Hz flicker response, and light-adapted cone response. OP amplitudes measured in patients were smaller than those of controls for O2 and O3. Multifocal ERGs recorded from ten randomly selected patients showed smaller N1–P1 amplitudes and longer latencies throughout the 25-deg central field. Full-field ERGs showed that scotopic, photopic, peripheral, and midperipheral retinal functions were affected, and the mfERGs indicated that central retinal function was also significantly depressed. To our knowledge, this is the first demonstration of retinal involvement in visual losses caused by mercury toxicity.
1 May 2007 in Investigative Ophthalmology & Visual Science
Purpose. Leber’s hereditary optic neuropathy (LHON) is a maternally inherited disease resulting in loss of central vision and dyschromatopsia, caused by mitochondrial DNA point mutations. However, only a subset of the mutation carriers becomes affected, with a higher penetrance in males. This study was conducted to investigate chromatic losses in asymptomatic carriers of the LHON mutation. methods. Monocular chromatic discrimination was studied with the Cambridge Colour Test (CCT; Cambridge Research Systems, Ltd., Rochester, UK) along the protan, deutan, and tritan cone isolation axes in 46 LHON carriers (15 men) belonging to the same LHON maternal lineage and 74 age-matched control subjects (39 men). Inclusion criteria were absence of ophthalmic complaints and clear ocular media. A detailed neuro-ophthalmic examination was performed in all the LHON carriers. results. The differences in threshold between carriers and control subjects were significant for the three cone isolation axes at P < 0.0001. Sixty-five percent of the carriers had abnormal protan and/or deutan thresholds; some of those with higher thresholds also had elevated tritan thresholds (13%). The male thresholds were higher and more frequent than those of the women for the protan and deutan axes (ANOVA; P < 0.05), but not for tritan thresholds. In the most severe losses, the women had instances of diffuse defect whereas all the men displayed a red–green defect. conclusions. Male LHON asymptomatic carriers had color vision losses with the red–green pattern of dyschromatopsia typical of patients affected with LHON, which includes elevation of tritan thresholds as well. This predominantly parvocellular (red–green) impairment is compatible with the histopathology of LHON, which affects mostly the papillomacular bundle. In contrast with male losses, female losses were less frequent and severe. These gender differences are relevant to understanding LHON pathophysiology, suggesting that hormonal factors may be of great importance.