Marcelo Miglioranza

Prof. Marcelo Miglioranza

PREVENCOR - Hospital Mae de Deus
+2
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2015 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
LGLuna Gargani
Luna Gargani
PPP. S. Pang
P. S. Pang
FFF. Frassi
F. Frassi
MMMarcelo Miglioranza
Marcelo Miglioranza
FDF. L. Dini
F. L. Dini
EPE. Picano
E. Picano
B-lines evaluated by lung ultrasound (LUS) are the sonographic sign of pulmonary congestion, a major predictor of morbidity and mortality in patients with heart failure (HF). Our aim was to assess the prognostic value of B-lines at discharge to predict rehospitalization at 6 months in patients with acute HF (AHF). A prospective cohort of 100 patients admitted to a Cardiology Department for dyspnea and/or clinical suspicion of AHF were enrolled (mean age 70 ± 11 years). B-lines were evaluated at admission and before discharge. Subjects were followed-up for 6-months after discharge. Mean B-lines at admission was 48 ± 48 with a statistically significant reduction before discharge (20 ± 23, p < .0001). During follow-up, 14 patients were rehospitalized for decompensated HF. The 6-month event-free survival was highest in patients with less B-lines (≤ 15) and lowest in patients with more B-lines (> 15) (log rank χ2 20.5, p < .0001). On multivariable analysis, B-lines > 15 before discharge (hazard ratio [HR] 11.74; 95 % confidence interval [CI] 1.30–106.16) was an independent predictor of events at 6 months. Persistent pulmonary congestion before discharge evaluated by ultrasound strongly predicts rehospitalization for HF at 6-months. Absence or a mild degree of B-lines identify a subgroup at extremely low risk to be readmitted for HF decompensation.

2 July 2015 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
LBLuigi P. Badano
Luigi P. Badano
MMMarcelo Miglioranza
Marcelo Miglioranza
TEThor Edvardsen
Thor Edvardsen
ACAlexandre Siciliano Colafranceschi
Alexandre Siciliano Colafranceschi
DMDenisa Muraru
Denisa Muraru
SSSebastian Sarvari
Sebastian Sarvari
The cohort of long-term survivors of heart transplant is expanding, and the assessment of these patients requires specific knowledge of the surgical techniques employed to implant the donor heart, the physiology of the transplanted heart, complications of invasive tests routinely performed to detect graft rejection (GR), and the specific pathologies that may affect the transplanted heart. A joint EACVI/Brazilian cardiovascular imaging writing group committee has prepared these recommendations to provide a practical guide to echocardiographers involved in the follow-up of heart transplant patients and a framework for standardized and efficient use of cardiovascular imaging after heart transplant. Since the transplanted heart is smaller than the recipient's dilated heart, the former is usually located more medially in the mediastinum and tends to be rotated clockwise. Therefore, standard views with conventional two-dimensional (2D) echocardiography are often difficult to obtain generating a large variability from patient to patient. Therefore, in echocardiography laboratories equipped with three-dimensional echocardiography (3DE) scanners and specific expertise with the technique, 3DE may be a suitable alternative to conventional 2D echocardiography to assess the size and the function of cardiac chambers. 3DE measurement of left (LV) and right ventricular (RV) size and function are more accurate and reproducible than conventional 2D calculations. However, clinicians should be aware that cardiac chamber volumes obtained with 3DE cannot be compared with those obtained with 2D echocardiography. To assess cardiac chamber morphology and function during follow-up studies, it is recommended to obtain a comprehensive echocardiographic study at 6 months from the cardiac transplantation as a baseline and make a careful quantitation of cardiac chamber size, RV systolic function, both systolic and diastolic parameters of LV function, and pulmonary artery pressure. Subsequent echocardiographic studies should be interpreted in comparison with the data obtained from the 6-month study. An echocardiographic study, which shows no change from the baseline study, has a high negative predictive value for GR. There is no single systolic or diastolic parameter that can be reliably used to diagnose GR. However, in case several parameters are abnormal, the likelihood of GR increases. When an abnormality is detected, careful revision of images of the present and baseline study (side-by-side) is highly recommended. Global longitudinal strain (GLS) is a suitable parameter to diagnose subclinical allograft dysfunction, regardless of aetiology, by comparing the changes occurring during serial evaluations. Evaluation of GLS could be used in association with endomyocardial biopsy (EMB) to characterize and monitor an acute GR or global dysfunction episode. RV size and function at baseline should be assessed using several parameters, which do not exclusively evaluate longitudinal function. At follow-up echocardiogram, all these parameters should be compared with the baseline values. 3DE may provide a more accurate and comprehensive assessment of RV size and function. Moreover, due to the unpredictable shape of the atria in transplanted patients, atrial volume should be measured using the discs' summation algorithm (biplane algorithm for the left atrium) or 3DE. Tricuspid regurgitation should be looked for and properly assessed in all echocardiographic studies. In case of significant changes in severity of tricuspid regurgitation during follow-up, a 2D/3D and colour Doppler assessment of its severity and mechanisms should be performed. Aortic and mitral valves should be evaluated according to current recommendations. Pericardial effusion should be serially evaluated regarding extent, location, and haemodynamic impact. In case of newly detected pericardial effusion, GR should be considered taking into account the overall echocardiographic assessment and patient evaluation. Dobutamine stress echocardiography might be a suitable alternative to routine coronary angiography to assess cardiac allograft vasculopathy (CAV) at centres with adequate experience with the methodology. Coronary flow reserve and/or contrast infusion to assess myocardial perfusion might be combined with stress echocardiography to improve the accuracy of the test. In addition to its role in monitoring cardiac chamber function and in diagnosis the occurrence of GR and/or CAV, in experienced centres, echocardiography might be an alternative to fluoroscopy to guide EMB, particularly in children and young women, since echocardiography avoids repeated X-ray exposure, permits visualization of soft tissues and safer performance of biopsies of different RV regions. Finally, in addition to the indications about when and how to use echocardiography, the document also addresses the role of the other cardiovascular imaging modalities during follow-up of heart transplant patients. In patients with inadequate acoustic window and contraindication to contrast agents, pharmacological SPECT is an alternative imaging modality to detect CAV in heart transplant patients. However, in centres with adequate expertise, intravascular ultrasound (IVUS) in conjunction with coronary angiography with a baseline study at 4–6 weeks and at 1 year after heart transplant should be performed to exclude donor coronary artery disease, to detect rapidly progressive CAV, and to provide prognostic information. Despite the fact that coronary angiography is the current gold-standard method for the detection of CAV, the use of IVUS should also be considered when there is a discrepancy between non-invasive imaging tests and coronary angiography concerning the presence of CAV. In experienced centres, computerized tomography coronary angiography is a good alternative to coronary angiography to detect CAV. In patients with a persistently high heart rate, scanners that provide high temporal...

1 November 2013 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
MMMarcelo Miglioranza
Marcelo Miglioranza
LGLuna Gargani
Luna Gargani
RSRoberto Tofani Sant'ANna
Roberto Tofani Sant'ANna
MRMarciane Maria Rover
Marciane Maria Rover
VMVitor Magnus Martins
Vitor Magnus Martins
TLTiago Luiz Luz Leiria
Tiago Luiz Luz Leiria

14 July 2023 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
LGLuna Gargani
Luna Gargani
NGNicolas Girerd
Nicolas Girerd
EPElke Platz
Elke Platz
PPPierpaolo Pellicori
Pierpaolo Pellicori
ISIvan Stankovic
Ivan Stankovic
LSLeyla Elif Sade
Leyla Elif Sade
Luna Gargani, Nicolas Girerd, Elke Platz, Pierpaolo Pellicori, Ivan Stankovic, Alberto Palazzuoli, Emanuele Pivetta, Marcelo Haertel Miglioranza, Hatem Soliman-

1 August 2014 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
Denisa MuraruDenisa Muraru
Denisa Muraru
UCUmberto Cucchini
Umberto Cucchini
SMSorina Mihăilă
Sorina Mihăilă
MMMarcelo Miglioranza
Marcelo Miglioranza
PAPatrizia Aruta
Patrizia Aruta
LBLuigi P. Badano
Luigi P. Badano

18 January 2017 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
EPEugenio Picano
Eugenio Picano
QCQuirino Ciampi
Quirino Ciampi
Rodolfo CitroRodolfo Citro
Rodolfo Citro
Antonello D'AndreaAntonello D'Andrea
Antonello D'Andrea
MSMaria Chiara Scali
Maria Chiara Scali
PCPaolo Colonna
Paolo Colonna
Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial disease in genotype-positive, phenotype- negative healthy relatives of inherited disease (such as hypertrophic cardiomyopathy). We expect to recruit about 10,000 patients over a 5-year period (2016-2020), with sample sizes ranging from 5,000 for coronary flow velocity/ left ventricular elastance/ B-lines in CAD to around 250 for hypertrophic cardiomyopathy or repaired Tetralogy of Fallot. This data-base will allow to investigate technical questions such as feasibility and reproducibility of various SE parameters and to assess their prognostic value in different clinical scenarios. The study will create the cultural, informatic and scientific infrastructure connecting high-volume, accredited SE labs, sharing common criteria of indication, execution, reporting and image storage of SE to obtain original safety, feasibility, and outcome data in evidence-poor diagnostic fields, also outside the established core application of SE in CAD based on regional wall motion abnormalities. The study will standardize procedures, validate emerging signs, and integrate the new information with established knowledge, helping to build a next-generation SE lab without inner walls.