Marcelo M F Saba

Dr. Marcelo M F Saba

National Institute for Space Research, São José dos Campos, São Paulo, Brazil
orcid

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2006 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
MBM. G. Ballarotti
M. G. Ballarotti
OPO. Pinto
O. Pinto
From analysis of digital high‐speed video records of 233 negative cloud‐to‐ground (CG) lightning flashes associated with 27 thunderstorms in southeastern Brazil, various lightning properties have been determined. The analysis of the video records showed that although 20% of them were single‐stroke flashes and the average number of strokes per flash was 3.8, a significant variation was observed in these parameters from storm to storm. In a smaller subset containing 138 flashes, 70 (51%) had multiple terminations on the ground. As 138 flashes produced 235 different strike points, the average number of strike points per CG flash was 1.70. Considering that in this study the missing of strokes is practically negligible, we can say from the average multiplicity and from the average number of strike points per flash that each ground contact point is, on average, struck 2.2 times. The 608 time intervals between strokes of 186 negative multiple‐stroke flashes presented a geometric mean value of 61 ms. Although time intervals preceding subsequent strokes that create a new termination tend to be greater than intervals between subsequent strokes that follow the previously formed channel, the difference was not statistically significant. A strong positive correlation between the number of subsequent strokes in a flash and the flash minimum duration may indicate that some processes concerning the time requisite for the channel decay and for the positive leader in the cloud to provide more charges for the next stroke do not permit multiple strokes to occur under a certain minimum time duration.

1 April 2008 in Geophysical Research Letters
Verified
Journal Article
Closed access
PDF file
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
KCKenneth L. Cummins
Kenneth L. Cummins
TWTom A. Warner
Tom A. Warner
EKE. Philip Krider
E. Philip Krider
LCLeandro Z. S. Campos
Leandro Z. S. Campos
SFStacy A. Fleenor
Stacy A. Fleenor

1 January 2014 in Atmospheric Research
Verified
Journal Article
Closed access
LCLeandro Z.S. Campos
Leandro Z.S. Campos
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
TWTom A. Warner
Tom A. Warner
OPOsmar Pinto
Osmar Pinto
EKE. Philip Krider
E. Philip Krider
RORichard E. Orville
Richard E. Orville

16 December 2010 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
WSWolfgang Schulz
Wolfgang Schulz
TWTom A. Warner
Tom A. Warner
LCLeandro Z. S. Campos
Leandro Z. S. Campos
CSCarina Schumann
Carina Schumann
RORichard E. Orville
Richard E. Orville
Although positive lightning flashes to ground are not as frequent as negative flashes, their large amplitudes and destructive characteristics make understanding their parameters an important issue. This study summarizes the characteristics of 103 positive cloud‐to‐ground (+CG) flashes that have been recorded using high‐speed video cameras (up to 11,800 frames per second) in three countries together with time‐correlated data provided by lightning location systems (LLS). A large fraction of the +CG flashes (81%) produced just a single stroke, and the average multiplicity was 1.2 strokes per flash. All the subsequent strokes in multiple‐stroke +CG flashes created a new ground termination except one. The geometric mean of 21 interstroke time intervals was 94 ms, which is about 1.5 times larger than the average interstroke interval in negative CG flashes (∼60 ms); 75% of the +CG flashes contained at least one long continuing current (LCC) ≥ 40 ms, and this percentage is significantly larger than in the negative flashes that produce LCCs (approximately 30%). The median estimated peak current (Ip) for 116 positive strokes that created new ground terminations was 39.4 kA. Positive strokes with a large Ip were usually followed by a LCC, and both of these parameters are threats in lightning protection. The characteristics presented here include the multiplicities of strokes and ground contacts, the percentage of single‐stroke flashes, the average interstroke time interval, the durations of the continuing current, and the distributions of Ip, the total flash durations, and the 2‐D leader speeds.

2 December 2005 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
MBM. G. Ballarotti
M. G. Ballarotti
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
OPO. Pinto
O. Pinto
A study of cloud‐to‐ground lightning characteristics based on high‐speed camera observations of 455 flashes related to 40 thunderstorms is presented. The Brazilian Lightning Location Network (RINDAT) was used to calculate the polarity and the distance of the flashes to the camera. In some cases, a fast electric field flat antenna was also used to calculate the time difference between strokes on a microsecond‐scale. Some general features of the data set are briefly presented. This paper is focused on two specific characteristics observed in video records with a frame a rate of 1,000 frames/s: (i) six strokes presenting two ground terminations that were simultaneously connected for some milliseconds, (ii) and a high number of continuing current occurrences with durations less than 10 ms.

1 June 2007 in Atmospheric Research
Verified
Journal Article
Closed access
LCLeandro Z.S. Campos
Leandro Z.S. Campos
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
OPOsmar Pinto
Osmar Pinto
MBMaurício G. Ballarotti
Maurício G. Ballarotti