Marcos Eduardo Gonzalez-Trevizo

Dr. Marcos Eduardo Gonzalez-Trevizo

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Energy and Buildings
Verified
Journal Article
Closed access
MGMarcos Eduardo Gonzalez-Trevizo
Marcos Eduardo Gonzalez-Trevizo
KMK.E. Martinez-Torres
K.E. Martinez-Torres
JAJ.F. Armendariz-Lopez
J.F. Armendariz-Lopez
MSM. Santamouris
M. Santamouris
GBG. Bojorquez-Morales
G. Bojorquez-Morales
ALA. Luna-Leon
A. Luna-Leon

5 July 2023 in Energy and Buildings
Verified
Journal Article
Closed access
SMS. Morales-Inzunza
S. Morales-Inzunza
MGMarcos Eduardo Gonzalez-Trevizo
Marcos Eduardo Gonzalez-Trevizo
KMKaren Estrella Martínez-Torres
Karen Estrella Martínez-Torres
ALAníbal Luna-León
Aníbal Luna-León
UTUlises-Jesus Tamayo-Perez
Ulises-Jesus Tamayo-Perez
Mst SantamourisMst Santamouris
Mst Santamouris

1 September 2018 in Journal of Cleaner Production
Verified
Journal Article
Closed access
JAJ.F. Armendariz-Lopez
J.F. Armendariz-Lopez
AAA.P. Arena-Granados
A.P. Arena-Granados
MGMarcos Eduardo Gonzalez-Trevizo
Marcos Eduardo Gonzalez-Trevizo
ALA. Luna-Leon
A. Luna-Leon
GBG. Bojorquez-Morales
G. Bojorquez-Morales

1 March 2016 in Renewable Energy
Verified
Journal Article
Closed access
JAJ.F. Armendariz-Lopez
J.F. Armendariz-Lopez
ALA. Luna-Leon
A. Luna-Leon
MGMarcos Eduardo Gonzalez-Trevizo
Marcos Eduardo Gonzalez-Trevizo
AAA.P. Arena-Granados
A.P. Arena-Granados
GBG. Bojorquez-Morales
G. Bojorquez-Morales

17 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
Carlos Javier Esparza-LópezCarlos Javier Esparza-López
Carlos Javier Esparza-López
CPCarlos Escobar-del Pozo
Carlos Escobar-del Pozo
Karam Al-ObaidiKaram Al-Obaidi
Karam Al-Obaidi
MGMarcos Eduardo Gonzalez-Trevizo
Marcos Eduardo Gonzalez-Trevizo
This study investigated an indirect evaporative cooling system (IECS) to control latent heat loss on roof ponds by increasing the evaporation rates on wet fabric membranes. The cooling potential of the proposed system was experimentally tested in a real environment and it was compared against a roof pond and a floating fiber (gunny bags) to provide an efficient model for buildings in hot and humid climates. Dry bulb temperatures (DBT) are presented for four experimental models. Solar irradiance, ambient and indoor dry bulb temperatures, and relative humidity (RH) were measured for seven days in each of the following climate conditions: hot sub-humid (mean DBT 27.3 °C and mean RH 72%), hot humid (mean DBT 27.1 °C and mean RH 81%), and warm sub-humid (mean DBT 25.2 °C and mean RH 68%). There were no significant variations in thermal performance between the examined devices under hot humid conditions; however, the wet fabric device had superior thermal performance under sub-humid conditions when compared to the other IECSs. In the three climatic scenarios where the proposed system was tested, the wet fabric managed to reduce the indoor air temperature by 6.6 °C, 5.3 °C, and 5.1 °C, respectively, as compared to the outdoor air temperatures.

1 April 2022 in Ingeniería Investigación y Tecnología
Verified
Journal Article
Closed access
JMJulio César Rincón Martínez
Julio César Rincón Martínez
CGCarmen García Gómez
Carmen García Gómez
MGMarcos Eduardo Gonzalez-Trevizo
Marcos Eduardo Gonzalez-Trevizo
Los estudios sobre confort térmico desarrollados bajo las bases metodológicas del enfoque adaptativo, advierten una dependencia importante de la sensación térmica de los sujetos respecto a las condiciones climáticas exteriores del lugar habitado. Las condiciones adversas del ambiente térmico pueden influir negativamente en el bienestar, la eficiencia y el confort de los sujetos, lo que deriva en la subutilización de los espacios cuyas condiciones higrotérmicas son inapropiadas para la actividad para la que fueron construidos. El objetivo de este trabajo consiste en estimar el rango de confort higrotérmico para espacios exteriores en dos bioclimas representativamente extremos en México: Cálido-húmedo y Semifrío-seco. El primero presenta una temperatura media anual de 26.2 °C y una precipitación total anual de 1,094.8 mm, mientras que el segundo, una de 17.3 °C y una de 217.3 mm, respectivamente. Los estudios son de tipo correlacional y fueron analizados con 605 evaluaciones y el registro simultáneo de la temperatura, la humedad relativa y la velocidad de viento, durante el periodo cálido. Los cuestionarios aplicados se diseñaron con base en la ISO 10551 y la ANSI/ASHRAE 55; asimismo, los instrumentos de medición física se establecieron a partir de la ISO 7726. Los datos recabados fueron procesados estadísticamente con el método de Medias por Intervalos de Sensación Térmica. El rango de confort higrotérmico estimado para el bioclima Cálido-húmedo fue de 21.8 °C a 34.9 °C para la temperatura y de 38.3 % a 85.8 % para la humedad relativa, mientras que para el Semifrío-seco fue de 19.4 °C a 25.0 °C y de 54.2 % a 84.0 %, respectivamente. Estas estimaciones responden a la adaptación que las personas presentan con su ambiente inmediato, a razón de las condiciones climáticas locales de cada lugar y el periodo de evaluación estudiado.