Mario Alves da Silva

Dr. Mario Alves da Silva

Faculty of Engineering, Free University of Bozen-Bolzano, Bolzano, Trentino-Alto Adige, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2024 in International Journal of Architectural Computing
Verified
Journal Article
Closed access
MSMario Alves da Silva
Mario Alves da Silva
RGRafael de Paula Garcia
Rafael de Paula Garcia
JCJoyce Correna Carlo
Joyce Correna Carlo
The increasing development in the computational field that allowed software and hardware advances enables more refined building performance analysis. Simulation-based optimization (SBO) methods allow high standards to be achieved by combining parametric modeling, simulation, and optimization methods. However, SBO methods still need development, especially regarding the correct choice of the optimization algorithm based on the specific characteristics of each problem. This study proposes a multi-objective optimization algorithms benchmark by comparing seven multi-objective optimization algorithms: RBFMOpt, NSGA2, MHACO, NSPSO, MOEA/D, HypE, and SPEA2, across nine building-related problems, including thermal, energy, and daylight simulation. The problems varied from 5 to 18 discrete, continuous, and mixed parameters. The objective functions varied between two and three. We used the hypervolume indicator, IGD+, GD+, and EPS + to compare algorithms’ performance and assess the tendency to reduce computational costs. We also performed the Kruskal-Wallis non-parametric test to analyze the impact of multiple runs on the hypervolume indicator. The results showed that RBFMOpt and HypE perform best across all problems. However, RBFMOpt tends to reduce computational costs since the algorithm requires fewer simulations to obtain the best results.

14 November 2022 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
MSMario Alves da Silva
Mario Alves da Silva
RGRafael de Paula Garcia
Rafael de Paula Garcia
JCJoyce Correna Carlo
Joyce Correna Carlo
Simulation-based Optimization processes (SBO) can be valuable methods in searching for efficient buildings. This study evaluates the performance of the multi-objective algorithms RBFMOpt, NSGA2, and MHACO facing the same SBO problem. The goal is to maximize thermal comfort while minimizing the energy consumption with HVAC systems for a typical Brazilian office building. We proposed a scoring method based on four algorithms’ performance metrics: hypervolume, variability, IGD+, and coverage. We also applied a Kruskal–Wallis test to determine whether the SBO process needs multiple runs to obtain the average performance of each algorithm. The results show that RBFMOpt presents the best performance, reaching a higher score, especially in situations with low budgets for the simulation and optimization process. The results also pointed out that the number of cycles for RBFMOpt impacts directly the quality of solutions, and a higher number of cycles provided better results.

20 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
MSMario Alves da Silva
Mario Alves da Silva
GPGiovanni Pernigotto
Giovanni Pernigotto
AGAndrea Gasparella
Andrea Gasparella
JCJoyce Correna Carlo
Joyce Correna Carlo
Representative weather data are fundamental to characterizing a place and determining ideal design approaches. This is particularly important for large countries like Brazil, whose extension and geographical position contribute to defining diverse climatic conditions along the territory. In this context, this study intends to characterize the Brazilian territory based on a 15-year weather record (2008–2022), providing a climatic assessment based on a climatic and bioclimatic profile for the whole country. The climate analysis was focused on temperature, humidity, precipitation, and solar radiation, followed by a bioclimatic analysis guided by the Givoni chart and the natural ventilation potential assessment. In both situations, the results were analyzed using three resolutions: country-level, administrative division, and bioclimatic zones. This study also identified representative locations for the Brazilian bioclimatic zones for a building-centered analysis based on the thermal and energy performance of a single-family house with different envelope configurations. The results proved that most Brazilian territories increased above 0.4 °C in the dry bulb temperature and reduced relative humidity. The precipitation had the highest reduction, reaching more than 50% for some locations. The warmer and drier conditions impacted also the Köppen–Geiger classification, with an increase in the number of Semi-Arid and Arid locations. The bioclimatic study showed that ventilation is the primary strategy for the Brazilian territory, as confirmed by the natural ventilation potential results, followed by passive heating strategies during the year’s coldest months. Finally, building performance simulation underlined that, in colder climates, indoor thermal comfort conditions and air-conditioning demands are less affected by solar absorptance for constructions with low U-values, while in warmer climates, low solar absorptance with intermediary U-values is recommended.

22 September 2025 in PARC: Pesquisa em Arquitetura e Construção
Verified
Journal Article
Open access
PDF file
MOMatheus Menezes Oliveira
Matheus Menezes Oliveira
CLCaio de Carvalho Lucarelli
Caio de Carvalho Lucarelli
MSMario Alves da Silva
Mario Alves da Silva
RMRaquel de Fátima Saith Marques
Raquel de Fátima Saith Marques
TMThaís de Souza Magalhães
Thaís de Souza Magalhães
JCJoyce Correna Carlo
Joyce Correna Carlo
Incorporating Phase Change Materials (PCMs) into indoor environments can enhance users' thermal comfort and improve the building's energy efficiency. However, the number of PCM studies in hot and humid climates, such as most Brazilian conditions, is comparatively less developed than research for temperate climates. This article investigates the influence of climatic parameters on the PCMs' function to enhance user thermal comfort in an office model in Brazilian climates employing thermo-energy simulation using EnergyPlus for 95 cities with adaptive thermal comfort as a performance indicator. We employed machine learning techniques, including Gradient Boosting and Feature Importance, to quantify the influence of climate parameters, followed by Principal Component Analysis clustering. Results show that incorporating PCMs can potentially increase user thermal comfort in part of Brazil, mainly in cities with average temperatures below 21°C. The comfort increase is not homogeneous, being more relevant in regions with colder temperatures and higher altitudes. When considering better-performing cities, the most influential climatic parameters were dry bulb temperature, relative humidity, and wind direction.


29 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
MSMario Alves da Silva
Mario Alves da Silva
GBGregorio Borelli
Gregorio Borelli
AGAndrea Gasparella
Andrea Gasparella
GPGiovanni Pernigotto
Giovanni Pernigotto
Data scarcity limits robust assessment of urban overheating and its implications for building energy use, especially in complex-terrain cities such as those in mountain environments. In this context, Land Surface Temperature (LST) from thermal remote sensing can be used to map urban hotspots at high spatial resolution. Nevertheless, it does not provide the full set of hourly atmospheric variables required to run building energy simulations aimed at quantifying their impact and defining mitigation measures. Given these premises, this study proposes a methodology combining satellite-derived LST with ground meteorological measurements to assess Urban Heat Island (UHI) patterns and quantify how measured weather data selection affects urban building energy modeling (UBEM) outcomes. After selecting as a case study Bolzano, an Alpine city in Northern Italy, ECOSTRESS LST (2019–2025, May–August) was first processed and quality-screened to (1) compute ΔLST (urban–rural) and (2) identify diurnal and spatial overheating patterns across the building stock. Second, four measured weather datasets—one rural station and three urban stations located in the city core, in the industrial district, and in the urban edge—were used as boundary conditions in an EnergyPlus-based UBEM parametric campaign for 253 residential buildings, covering multiple envelope insulation levels and window-to-wall ratios. Results show strong diurnal asymmetry in surface overheating, with the largest contrasts in the afternoon and prominent industrial hotspots. Ground measurements confirm persistent intra-urban microclimatic differences, and the choice of measured weather dataset causes systematic shifts in simulated cooling demand and thermal comfort. The study highlights the need for weather data selection strategies based on microclimatic context rather than simple proximity, improving representativeness in UBEM applications for Alpine and other heterogeneous urban environments.