Due to the accident of Fukushima Daiichi Nuclear Power Plant, some areas were contaminated by released radioisotopes (mainly 137Cs and 134Cs). Effective decontamination is demanded to encourage evacuated people to return. This paper proposes a new survey system using an unmanned helicopter equipped with a Compton camera for localizing radionuclides. As a prototype, 32 Ce:Gd3(Al,Ga)5O12 (GAGG) crystals were coupled to 16 silicon photomultipliers and 16 avalanched photodiodes as the scatterer and absorber, respectively. A new Dynamic Time-over-Threshold (dToT) method was applied to convert CR-RC shaping signals to digital signals for multi-channel spectra and coincidence acquisition. The system was designed to work in two modes: one is Compton-camera mode (CCM) which obtains the radiation distribution maps through Compton imaging using hovering flights, while the other one is Gamma-camera mode (GCM) which maps the radiation distribution via measured coincidence events using programmed flights. For point source in CCM, an intrinsic efficiency of 1.68% with a combined standard uncertainty of 0.04% and an angular resolution of about 14° (FWHM, full width at half maximum) was achieved. In GCM, a spatial resolution of about 11 cm (FWHM) was obtained when detecting area is 11.2 cm away from the detector, while it was about 28 cm (FWHM) in single detector mode (SDM). Promising results were obtained in field in Fukushima.
The 3 inch size Mg co-doped Ce : Gd 3 Al 2 Ga 3 O 12 single crystals were prepared by the Czochralski (Cz) method. Absorption and luminescence spectra were measured together with several other scintillation characteristics, namely the scintillation decay and light yield to reveal the effect of Mg co-doping. The timing resolution measurement for a pair of 3 × 3 × 3 mm 3 size GAGG:Ce.Mg scintillator crystals was performed using Si-PMs.
An improved light-weight Compton camera exhibiting low power consumption was developed to be mountable on an unmanned helicopter to detect cesium radiation hot spots and confirm the decontamination effect of cesium-affected areas. An increase in the Ce:Gd3(Al,Ga)5O12 scintillator array from 4 × 4 to 8 × 8 and expansion of the interlayer distance enhanced the detection efficiency and angular resolution, respectively. Measurements were performed over the Ukedo riverbed in Namie, Fukushima Prefecture (Japan). The helicopter's flight path and speed were pre-programmed to lines interspaced by 5 and 10 m intervals and 1 m/s, respectively, facilitating measurements over areas of 65 × 60 m2 and 65 × 180 m2 at a height of 10 m for approximately 20 and 30 min, respectively. Results provided accurate ambient dose equivalent rate maps at a height of 1 m with an angular resolution corresponding to a position resolution of approximately 10 m from a height of 10 m. Hovering flights were executed over hot-spot areas for 10–20 min at a height of 5–20 m. Gamma-ray images of these hot spots were obtained using a reconstruction software. Comparison between position-shifted measurement results showed that the angular resolution coincided with that evaluated in the laboratory (approximately 10°).
1 December 2018 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment