Mahmoud A. Tantawy

Dr. Mahmoud A. Tantawy

Department of Pharmaceutical Chemistry and Pharmacognosy, College of Pharmacy, Qassim University, Buraydah, Al Qaşīm, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Analytica Chimica Acta
Verified
Journal Article
Closed access
AYAli M. Yehia
Ali M. Yehia
MFMohamed A. Farag
Mohamed A. Farag
MTMahmoud A. Tantawy
Mahmoud A. Tantawy

11 February 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MWMina Wadie
Mina Wadie
HMHoda M. Marzouk
Hoda M. Marzouk
MRMamdouh R. Rezk
Mamdouh R. Rezk
EAEzzat M. Abdel-Moety
Ezzat M. Abdel-Moety
MTMahmoud A. Tantawy
Mahmoud A. Tantawy

1 June 2021 in Microchemical Journal
Verified
Journal Article
Closed access
MWMina Wadie
Mina Wadie
EAEzzat M. Abdel-Moety
Ezzat M. Abdel-Moety
MRMamdouh R. Rezk
Mamdouh R. Rezk
MTMahmoud A. Tantawy
Mahmoud A. Tantawy

19 June 2020 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MTMahmoud A. Tantawy
Mahmoud A. Tantawy
SWSoheir A. Weshahy
Soheir A. Weshahy
MWMina Wadie
Mina Wadie
MRMamdouh R. Rezk
Mamdouh R. Rezk
Stability and impurity profiling are in high demand to guarantee the potency, safety and efficacy of new formulations along with their shelf-life. In this study, stability testing of alfuzosin (ALF) and solifenacin (SOL) in their newly co-formulated capsules was conducted under different stress conditions. The obtained degradation products were structurally elucidated and found to be their official impurities, namely; ALF impurity-D and SOL impurities-A, E & I. A selective and reliable stability-indicating HPLC method was developed for assaying the cited drugs along with three of those official impurities. Chromatographic separation was accomplished within 8 minutes using a XBridge® C18 column as the stationary phase and acetonitrile : phosphate buffer (pH 8) : triethylamine (60 : 40 : 0.02, by volume) as the mobile phase at a flow rate of 1.3 mL min−1. Quantification of the analytes was performed at 210 nm using a diode array detector through which peak purity was assessed. The proposed method was validated as per ICH guidelines and it was successfully applied for the determination of the cited drugs in their combined pharmaceutical formulation with percent recoveries of 100.47 and 100.15 for ALF and SOL, respectively. Moreover, the proposed method was exploited for the assessment of the two drugs' stability in Solitral® capsules under accelerated storage conditions. The method was further extended for studying the degradation kinetics of the two drugs.

20 April 2020 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
MTMahmoud A. Tantawy
Mahmoud A. Tantawy
Mohamed FaragMohamed Farag
Mohamed Farag
AYAli M. Yehia
Ali M. Yehia
This work describes a dual-mode colorimetric and fluorometric nanoprobe for determination of ketamine hydrochloride (KET) in soda beverages. KET is a widely known club drug that is spiked in beverages to get rape victims vulnerable. The proposed nanoprobe utilizes gold nanoparticles (AuNPs) and fluorescent carbon dots (CDs). AuNPs act as a color probe and quencher of CDs fluorescence. KET destabilizes the citrate-capped AuNPs leading to a color change and subsequent disruption of the inner filter quenching mechanism in this acceptor/donor pair. Nanoparticles are characterized by transmission electron microscopy as well as molecular absorption and emission spectroscopy. The dual-detection mode has been optimized for the concentration of nanoparticles, reaction time and medium pH. The fluorescence recovery efficiency of CDs and the absorbance ratio of AuNPs bands are used as analytical signals for dual detection of KET. A linear response in the range of 5 × 10−5–6.5 × 10−4 mol L−1 is achieved for the fluorescent sensor, with a detection limit of 2.32 × 10−5 mol L−1. The respective values for the color sensor are 1 × 10−4–9 × 10−4 and 2.70 × 10−5 mol L−1. The selectivity of this dual-mode nanoprobe has been investigated by application to different spiked soda drinks. The sensor exhibits good selectivity towards Sprite® and Coca-Cola® in the average oral KET dose; however, the orange coloration in Fanta® seems to have high absorbance over the AuNPs characteristic band that hinders the detection of KET at the average concentration level.

1 March 2013 in Journal of Advanced Research
Verified
Journal Article
Open access
MTMahmoud A. Tantawy
Mahmoud A. Tantawy
NHNagiba Y. Hassan
Nagiba Y. Hassan
NENariman A. Elragehy
Nariman A. Elragehy
MAMohamed Abdelkawy
Mohamed Abdelkawy
This paper describes sensitive, accurate and precise spectrophotometric, TLC-spectrodensitometric and high performance liquid chromatographic (HPLC) methods for simultaneous determination of olanzapine and fluoxetine HCl. Two spectrophotometric methods were developed, namely; first derivative (D (1)) and derivative ratio (DD (1)) methods. The TLC method employed aluminum TLC plates precoated with silica gel GF254 as the stationary phase and methanol:toluene:ammonia (7:3:0.1, by volume) as the mobile phase, where the chromatogram was scanned at 235 nm. The developed HPLC method used a reversed phase C18 column with isocratic elution. The mobile phase composed of phosphate buffer pH 4.0:acetonitrile:triethylamine (53:47:0.03, by volume) at flow rate of 1.0 mL min(-1). Quantitation was achieved with UV detection at 235 nm. The methods were validated according to the International Conference on Harmonization (ICH) guidelines. The selectivity of the proposed methods was tested using laboratory-prepared mixtures. The developed methods were successfully applied for the determination of olanzapine and fluoxetine HCl in bulk powder and combined capsule dosage form.