Matilde Pavan

Dr. Matilde Pavan

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Michaela CellinaMichaela Cellina
Michaela Cellina
MPMatilde Pavan
Matilde Pavan
NFNiccolò Finardi
Niccolò Finardi
FCFrancesco Cicchetti
Francesco Cicchetti
MCMaurizio Cè
Maurizio Cè
GCGianpaolo Carrafiello
Gianpaolo Carrafiello
Acute pulmonary embolism (APE) represents a significant cause of morbidity and mortality worldwide, requiring rapid and precise diagnosis and effective therapy strategies. Computed Tomography Pulmonary Angiography (CTPA) is currently the gold standard technique for diagnosing PE; however, it presents some disadvantages, including limited sensitivity in detecting sub-segmental emboli and contrast-related risks. Recent advancements in imaging technologies, including Dual-Energy Computed Tomography (DECT) and Photon Counting (PC), offer improved sensitivity and specificity for APE and perfusion abnormalities detection. Digital Dynamic Radiography (DDR) perfusion imaging represents a novel imaging that allows pulmonary perfusion assessment without contrast medium administration, able to detect anomalies at the patient’s bedside, representing a promising advancement, particularly for critically ill or contrast-allergic patients. In parallel, interventional radiology has become integral to APE management, particularly for high-risk and intermediate–high-risk patients, with evolving intravascular treatment techniques such as catheter-directed thrombolysis, mechanical thrombectomy, and thrombus aspiration. This narrative review provides an overview of the latest developments in APE diagnostic imaging and interventional radiology, contextualizing them within current guideline recommendations for endovascular treatment.

12 November 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SBSara Boemi
Sara Boemi
MPMatilde Pavan
Matilde Pavan
RSRoberta Siena
Roberta Siena
CGCarla Lo Giudice
Carla Lo Giudice
APAlessia Pagana
Alessia Pagana
MBMaria Teresa Bruno
Maria Teresa Bruno
Background: Locally advanced cervical cancer (LACC) represents a significant challenge in oncology, requiring accurate assessment of local extent and metastatic spread. Multiparametric magnetic resonance imaging (mpMRI) has assumed a central role in the loco-regional characterization of the tumor due to its high soft-tissue resolution and the ability to integrate functional information. Objectives: In this narrative review, we explore the use of mpMRI in the diagnosis, staging, and treatment response of LACC, comparing its performance with that of PET/CT, which remains complementary for remote staging. The potential of whole-body magnetic resonance imaging (WB-MRI) and hybrid PET/MRI techniques is also analyzed, as well as the emerging applications of radiomics and artificial intelligence. The paper also discusses technical limitations, interpretative variability, and the importance of protocol standardization. The goal is to provide an updated and translational summary of imaging in LACC, with implications for clinical practice and future research. Methods: Prospective and retrospective studies, systematic reviews, and meta-analyses on adult patients with cervical cancer were included. Results: Fifty-two studies were included. MRI demonstrated a sensitivity and specificity greater than 80% for parametrial and bladder invasion, but limited sensitivity (45–60%) for lymph node disease, lower than PET/CT. Multiparametric MRI was useful in early prediction of response to chemotherapy and radiotherapy and in distinguishing residual disease from fibrosis. The integration of MRI into Image-Guided Adaptive Brachytherapy (IGABT) resulted in improved oncological outcomes and reduced toxicity. The applications of radiomics and AI demonstrated enormous potential in predicting therapeutic response and lymph node status in the MRI study, but multicenter validation is still needed. Conclusions: MRI is the cornerstone of the local–regional staging of advanced cervical cancer; it has become an essential and crucial tool in treatment planning. Its use, combined with PET/CT for lymph node assessment and metastatic disease staging, is now the standard of care. Future prospects include the use of whole-body MRI and the development of predictive models based on radiomics and artificial intelligence.

20 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
JPJacopo Pozzi
Jacopo Pozzi
JDJacopo D’Argenzio
Jacopo D’Argenzio
SCSerena Carriero
Serena Carriero
MCMaurizio Cè
Maurizio Cè
DDDario D’Arrigo
Dario D’Arrigo
GCGianpaolo Carrafiello
Gianpaolo Carrafiello
Radiomics has produced tens of thousands of publications yet almost no handcrafted radiomic signatures in routine clinical use, and the reasons are increasingly understood to be problems of reproducibility and clinical translation rather than of algorithms. This critical narrative review argues that the field systematically generates paper-grade evidence—findings sufficient to publish—far faster than decision-grade evidence—findings sufficient to change clinical practice. Drawing on meta-scientific research, we describe seven fragility mechanisms (publication bias, analytical flexibility, underpowering, HARKing [hypothesizing after the results are known], citation distortion, cognitive bias, and misaligned incentives) and show why radiomics is structurally exposed to all of them simultaneously: high-dimensional feature spaces, acquisition-dependent measurement instability, segmentation variability, retrospective single-centre data, small samples, and leakage-prone validation. We then summarise empirical evidence on the radiomics literature, which remains pervaded by suboptimal methodological quality, near-absent negative results, limited external validation, sparse calibration and clinical-utility assessment, low data and code sharing, and a measurable retraction signal. We interpret these patterns as the output of a self-reinforcing system rather than isolated errors, and argue that better algorithms alone cannot resolve them. Finally, we argue that closing this gap requires not better models but evidentiary discipline: the consistent, enforceable application of standards the field already has, and the calibration of published claims to the strength of the underlying evidence.

22 April 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SASalvatore Alessio Angileri
Salvatore Alessio Angileri
GPGiuseppe Pellegrino
Giuseppe Pellegrino
CLCarolina Lanza
Carolina Lanza
JPJacopo Pozzi
Jacopo Pozzi
MCMarco Costa
Marco Costa
GCGianpaolo Carrafiello
Gianpaolo Carrafiello
Background/Objectives: the aim of this study was to evaluate the safety and efficacy of percutaneous transhepatic lithotripsy using the SpyGlassDSTM cholangioscopy system for the treatment of difficult stones. Methods: Retrospectively, all patients treated with percutaneous transhepatic lithotripsy using SpyGlassDSTM cholangioscopy system were analyzed. As primary outcome measures, the following data were assessed: the presence of a previous history of the hepatobiliary disease, location of stones, reasons for the choice of the procedure, previous balloon bilioplasty, type of pre-procedural imaging, procedural time, technical success, clinical success, and post-procedural complications (according to CIRSE classification). Clinical success was considered “primary” when achieved with a single treatment, and “secondary” if more than one treatment was required in the duration of follow-up. Results: 10 patients (6 males and 4 females, mean age = 64 years, SD = 22), all with cholangitis due to gallstones, underwent 11 PTL procedures using SpyGlassDSTM. Technical and clinical successes were achieved in all patients (100%). Primary success was observed in 4/10 (40%) patients, while the remaining 6/10 (60%) patients undergoing re-treatment, and all showed secondary success (100%). No periprocedural complications were observed. In 10/11 procedures (90%), no relevant adverse events were recorded within the first thirty days of follow-up. In 1/11 case (9%), mild complications (grade I according to CIRSE classification) were registered in the following days after the procedure (<30 days). Conclusions: in conclusion, the treatment of percutaneous transhepatic lithotripsy using SpyGlassDSTM cholangioscopy of difficult stones has been demonstrated as efficient and safe treatment.

3 June 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
JPJacopo Pozzi
Jacopo Pozzi
JDJacopo D’Argenzio
Jacopo D’Argenzio
SCSerena Carriero
Serena Carriero
MCMaurizio Cè
Maurizio Cè
DDDario D’Arrigo
Dario D’Arrigo
GCGianpaolo Carrafiello
Gianpaolo Carrafiello
Radiomics has produced tens of thousands of publications yet almost no tools in routine clinical use, and the reasons are increasingly understood to be problems of reproducibility and clinical translation rather than of algorithms. This critical narrative review argues that the field systematically generates paper-grade evidence—findings sufficient to publish—far faster than decision-grade evidence—findings sufficient to change clinical practice. Drawing on meta-scientific research, we describe seven fragility mechanisms (publication bias, analytical flexibility, underpowering, HARKing [hypothesizing after the results are known], citation distortion, cognitive bias, and misaligned incentives) and show why radiomics is structurally exposed to all of them simultaneously: high-dimensional feature spaces, acquisition-dependent measurement instability, segmentation variability, retrospective single-centre data, small samples, and leakage-prone validation. We then summarise empirical evidence on the radiomics literature, which remains pervaded by suboptimal methodological quality, near-absent negative results, limited external validation, sparse calibration and clinical-utility assessment, low data and code sharing, and a measurable retraction signal. We interpret these patterns as the output of a self-reinforcing system rather than isolated errors, and argue that better algorithms alone cannot resolve them. Finally, we argue that closing this gap requires not better models but evidentiary discipline: the consistent, enforceable application of standards the field already has, and the calibration of published claims to the strength of the underlying evidence.

24 January 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SCSerena Carriero
Serena Carriero
MCMaurizio Cè
Maurizio Cè
MPMatilde Pavan
Matilde Pavan
MPMariassunta Roberta Pannarale
Mariassunta Roberta Pannarale
GQGiulia Quercioli
Giulia Quercioli
SSSonia Santicchia
Sonia Santicchia
Background/Objectives: Vacuum-assisted excision (VAE) is a minimally invasive technique for breast tumor treatment, offering precision, comfort, and quick recovery. It is widely used for benign breast lesions and is playing an increasingly important role in the therapeutic management of non-surgical patients or patients who refuse surgery. Optimal outcomes require an understanding of device features to tailor treatment to each lesion. The Mammotome® Elite 10G operates in a fixed mode, while the Mammotome® Revolve EX 8G offers multiple aspiration levels and aperture windows for greater versatility. This study analyzed the specimen features (weight and length), comparing the weight obtained from two different VAE systems to aid the appropriate selection of a device based on the clinical setting. It also determined the number of specimens needed to achieve the 4 g diagnostic threshold. Methods: The Mammotome® Elite 10G and the Mammotome® Revolve EX were evaluated under controlled conditions. For Mammotome® Revolve EX, combinations of five aspiration levels and three aperture lengths (12 mm, 18 mm, and 25 mm) were tested. Twelve samples were collected from a chicken breast phantom for each setting. Specimen weights and the minimum excisions required to reach the 4 g threshold were analyzed. Results: The mean weight per sample for the Mammotome® Elite 10G was 0.16 ± 0.04 g. For the Mammotome® Revolve EX, the weights increased with aperture size and aspiration level, ranging from a minimum of 0.132 ± 0.028 g (a window length of 12 mm and aspiration level 1) to a maximum of 0.407 ± 0.055 g (a window length of 25 mm and aspiration level 5). The 25 mm window at aspiration level 5 achieved the 4 g threshold in as few as 10 samples. By comparison, the Mammotome® Elite required up to 26 samples. Conclusions: Compared to the Mammotome Elite, Mammotome® Revolve EX offers superior versatility and efficiency, reducing patient discomfort by minimizing the required samples. Its technical advantages make it a valuable tool for both diagnostic and therapeutic applications.