Digital construction is expected to reduce the high volume of waste and the labour shortage in the construction sector. The properties of hardened concrete used in 3D printing depend on numerous parameters within the manufacturing process. This study collected data using 208 specimens to measure the effect of the loading direction relative to the printing direction on the strength characteristics of printed concrete. The compressive strength was not significantly affected by the directions, but showed a 30% reduction from mould-casted strength due to lesser amount of compaction in the printing process. Flexural tensile strength showed a 14% reduction in one direction, possibly caused by heterogeneity due to the use of extrusion head with a 35% smaller diameter than the width of the layer. Splitting tensile strength was 14% lower when split between the printed layers. Splitting tensile strength is possibly 5% higher when PP fibres are oriented favourably.
The concept of integrating PV panels into traditional ETICS facades has been developing for several years. Problems concerning the options for passively controlling the temperatures of PV panels with PCM and directing excess moisture out of the wall via diffusion channels have been previously studied theoretically. During this study, real wall-scale experiments were conducted to test the thermal and hygrothermal performance of the wall system in an extreme climatic environment, as well as in a real outdoor environment in Tallinn, Estonia. Finally, a simulation model was calibrated according to the measured data. It was found that in case of test walls with diffusion channels, it was possible to keep the moisture content of PCM mortar under 0.11 m3/m3. Excess water drained out via channels leading to the external environment. Without diffusion channels, the moisture content rose as high as 0.18 m3/m3. Both the experiments and hygrothermal modelling showed that the high moisture content of PCM mortar, caused by water leakage, dropped to 0.08 m3/m3 over 10 solar cycles as moisture escaped via the diffusion channels. PCM mortar with a moisture content of 0.08 m3/m3 endured extreme rain and freeze-thaw cycles without visual damage, and PV panels retained their electrical production capabilities.
Several paints are marketed as “thermal-insulating and heat-reflective” (TIHR), claiming extraordinary performance, such as a 0.5 mm layer providing thermal resistance equivalent to 300 mm of traditional insulation. This study tested these claims by applying indoor and outdoor TIHR paint variants from a single supplier to 20 mm XPS slabs and comparing them to a regular façade paint using a heat flow meter, measuring heat flux and doing infrared thermography in climate chamber experiments. A total of six variations of two TIHR paints and two variations of a regular façade paint were studied. The TIHR paints did not perform any better than a regular façade paint. Results from both the heat flow meter and climate chamber experiments showed that the effect of any tested paints on thermal conductivity was negligible, the measured results underperformed the TIHR paint’s advertised value of 0.00005 W/(m·K) by a factor of 500.