James McNames

Dr. James McNames

Electrical and Computer Engineering, Portland State University, Portland, Connecticut, USA
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2006 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
James McNamesJames McNames
James McNames
MAMateo Aboy
Mateo Aboy

1 June 2001 in Journal of Vibration and Acoustics
Verified
Journal Article
Closed access
PDF file
James McNamesJames McNames
James McNames
Synchronous averaging is difficult to use with epicyclic gear systems because the dominant frequencies are slightly skewed and asymmetrical. This Tech Brief uses Fourier series analysis to add new insight to this phenomenon. The results are illustrated on vibration data recorded from a Cobra AH-1S helicopter gearbox.

1 December 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
VSVrutangkumar V Shah
Vrutangkumar V Shah
James McNamesJames McNames
James McNames
Martina ManciniMartina Mancini
Martina Mancini
Patricia (Patty) Carlson-KuhtaPatricia (Patty) Carlson-Kuhta
Patricia (Patty) Carlson-Kuhta
RSRebecca I. Spain
Rebecca I. Spain
FHFay Horak
Fay Horak
Background and purpose: Recent findings suggest that a gait assessment at a discrete moment in a clinic or laboratory setting may not reflect functional, everyday mobility. As a step towards better understanding gait during daily life in neurological populations, we compared gait measures that best discriminated people with multiple sclerosis (MS) and people with Parkinson’s Disease (PD) from their respective, age-matched, healthy control subjects (MS-Ctl, PD-Ctl) in laboratory tests versus a week of daily life monitoring. Methods: We recruited 15 people with MS (age mean ± SD: 49 ± 10 years), 16 MS-Ctl (45 ± 11 years), 16 people with idiopathic PD (71 ± 5 years), and 15 PD-Ctl (69 ± 7 years). Subjects wore 3 inertial sensors (one each foot and lower back) in the laboratory followed by 7 days during daily life. Mann–Whitney U test and area under the curve (AUC) compared differences between PD and PD-Ctl, and between MS and MS-Ctl in the laboratory and in daily life. Results: Participants wore sensors for 60–68 h in daily life. Measures that best discriminated gait characteristics in people with MS and PD from their respective control groups were different between the laboratory gait test and a week of daily life. Specifically, the toe-off angle best discriminated MS versus MS-Ctl in the laboratory (AUC [95% CI] = 0.80 [0.63–0.96]) whereas gait speed in daily life (AUC = 0.84 [0.69–1.00]). In contrast, the lumbar coronal range of motion best discriminated PD versus PD-Ctl in the laboratory (AUC = 0.78 [0.59–0.96]) whereas foot-strike angle in daily life (AUC = 0.84 [0.70–0.98]). AUCs were larger in daily life compared to the laboratory. Conclusions: Larger AUC for daily life gait measures compared to the laboratory gait measures suggest that daily life monitoring may be more sensitive to impairments from neurological disease, but each neurological disease may require different gait outcome measures.

17 December 2007 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
James McNamesJames McNames
James McNames
MAMateo Aboy
Mateo Aboy
Cardiovascular signals such as arterial blood pressure (ABP), pulse oximetry (POX), and intracranial pressure (ICP) contain useful information such as heart rate, respiratory rate, and pulse pressure variation (PPV). We present a novel state-space model of cardiovascular signals and describe how it can be used with the extended Kalman filter (EKF) to simultaneously estimate and track many cardiovascular parameters of interest using a unified statistical approach. We analyze data from four databases containing cardiovascular signals and present representative examples intended to illustrate the versatility, accuracy, and robustness of the algorithm. Our results demonstrate the ability of the algorithm to estimate and track several clinically relevant features of cardiovascular signals. We illustrate how the algorithm can be used to elegantly solve several actively researched and clinically significant problems including heart and respiratory rate estimation, artifact removal, pulse morphology characterization, and PPV estimation.

12 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
VSVrutangkumar V Shah
Vrutangkumar V Shah
James McNamesJames McNames
James McNames
GHGraham Harker
Graham Harker
Martina ManciniMartina Mancini
Martina Mancini
Patricia (Patty) Carlson-KuhtaPatricia (Patty) Carlson-Kuhta
Patricia (Patty) Carlson-Kuhta
FHFay Horak
Fay Horak
Although the use of wearable technology to characterize gait disorders in daily life is increasing, there is no consensus on which specific gait bout length should be used to characterize gait. Clinical trialists using daily life gait quality as study outcomes need to understand how gait bout length affects the sensitivity and specificity of measures to discriminate pathological gait as well as the reliability of gait measures across gait bout lengths. We investigated whether Parkinson’s disease (PD) affects how gait characteristics change as bout length changes, and how gait bout length affects the reliability and discriminative ability of gait measures to identify gait impairments in people with PD compared to neurotypical Old Adults (OA). We recruited 29 people with PD and 20 neurotypical OA of similar age for this study. Subjects wore 3 inertial sensors, one on each foot and one over the lumbar spine all day, for 7 days. To investigate which gait bout lengths should be included to extract gait measures, we determined the range of gait bout lengths available across all subjects. To investigate if the effect of bout length on each gait measure is similar or not between subjects with PD and OA, we used a growth curve analysis. For reliability and discriminative ability of each gait measure as a function of gait bout length, we used the intraclass correlation coefficient (ICC) and area under the curve (AUC), respectively. Ninety percent of subjects walked with a bout length of less than 53 strides during the week, and the majority (>50%) of gait bouts consisted of less than 12 strides. Although bout length affected all gait measures, the effects depended on the specific measure and sometimes differed for PD versus OA. Specifically, people with PD did not increase/decrease cadence and swing duration with bout length in the same way as OA. ICC and AUC characteristics tended to be larger for shorter than longer gait bouts. Our findings suggest that PD interferes with the scaling of cadence and swing duration with gait bout length. Whereas control subjects gradually increased cadence and decreased swing duration as bout length increased, participants with PD started with higher than normal cadence and shorter than normal stride duration for the smallest bouts, and cadence and stride duration changed little as bout length increased, so differences between PD and OA disappeared for the longer bout lengths. Gait measures extracted from shorter bouts are more common, more reliable, and more discriminative, suggesting that shorter gait bouts should be used to extract potential digital biomarkers for people with PD.

21 October 2020 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
PMPatrick Mcgurrin
Patrick Mcgurrin
James McNamesJames McNames
James McNames
TWTianxia Wu
Tianxia Wu
MHMark Hallett
Mark Hallett
DHDietrich Haubenberger
Dietrich Haubenberger
Background Assessment of essential tremor is often done by a trained clinician who observes the limbs during different postures and actions and subsequently rates the tremor. While this method has been shown to be reliable, the inter- and intra-rater reliability and need for training can make the use of this method for symptom progression difficult. Many limitations of clinical rating scales can potentially be overcome by using inertial sensors, but to date many algorithms designed to quantify tremor have key limitations. Methods We propose a novel algorithm to characterize tremor using inertial sensors. It uses a two-stage approach that 1) estimates the tremor frequency of a subject and only quantifies tremor near that range; 2) estimates the tremor amplitude as the portion of signal power above baseline activity during recording, allowing tremor estimation even in the presence of other activity; and 3) estimates tremor amplitude in physical units of translation (cm) and rotation (°), consistent with current tremor rating scales. We validated the algorithm technically using a robotic arm and clinically by comparing algorithm output with data reported by a trained clinician administering a tremor rating scale to a cohort of essential tremor patients. Results Technical validation demonstrated rotational amplitude accuracy better than ±0.2 degrees and position amplitude accuracy better than ±0.1 cm. Clinical validation revealed that both rotation and position components were significantly correlated with tremor rating scale scores. Conclusion We demonstrate that our algorithm can quantify tremor accurately even in the presence of other activities, perhaps providing a step forward for at-home monitoring.