Meirion Hills

Mr. Meirion Hills

Cardiff University
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
PWPhillip Widger
Phillip Widger
DCDaniel Carr
Daniel Carr
ARAlistair Reid
Alistair Reid
MHMeirion Hills
Meirion Hills
CSChris Stone
Chris Stone
Abderrahmane HaddadAbderrahmane Haddad
Abderrahmane Haddad
This paper uses practical experimentation to analyse the effect of replacing SF6 with pure CO2 in conventional gas insulated transmission line sections by studying partial discharge measurements taken with applied voltages up to 242 kV (rms). The results can also help in understanding the properties of new alternative gas mixtures which can be utilised with a ratio of up to and over 95% CO2. The experiments undertaken involved filling a gas insulated line demonstrator with 3 bars of CO2 and applying voltages up to 242 kV in both clean conditions and particle-contaminated enclosure conditions. The results demonstrate that CO2 can be used to insulate gas equipment without breakdown at high voltage, however, a higher gas-filling pressure may be needed to reduce the partial discharge found in the tests presented in this paper. Another aspect of the work showed that partial discharge (PD) measurements from internal ultra-high frequency (UHF) sensors compared with a direct measurement from a capacitive divider both clearly showed the effect of contaminating particles in CO2. However, the PD divider measurements also showed considerable external PD on the outside of the gas compartment, leading to the conclusion that UHF sensors are still regarded as having the highest sensitivity and noise immunity for gas insulated switchgear (GIS) or gas insulated transmission line (GIL) systems including when the equipment is insulated with CO2.

9 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PWPhillip Widger
Phillip Widger
DCDaniel Carr
Daniel Carr
MHMeirion Hills
Meirion Hills
ARAlistair Reid
Alistair Reid
The research in this paper consists of practical experimentation on a gas insulated section of high voltage equipment filled with carbon dioxide and technical air as a direct replacement to sulphur hexafluoride (SF6) and analyses the results of PD measurement by way of internal UHF sensors and external HFCTs. The results contribute to ongoing efforts to replace the global warming gas SF6 with an alternative such as pure carbon dioxide or technical air and are applicable to mixtures of electronegative gases that have a high content of buffer gas including carbon dioxide. The experiments undertaken involved filling a full-scale gas insulated line demonstrator with different pressures of CO2 or technical air and applying voltages up to 242 kV in both clean conditions and particle contaminated conditions. The results show that carbon dioxide and technical air can insulate a gas section normally insulated with SF6 at phase-to-earth voltage of 242 kV and that both HFCT and UHF sensors can be used to detect partial discharge with natural gases. The internal UHF sensors show the most accurate PD location results but external HFCTs offer a good compromise and very similar location accuracy.

12 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PWPhillip Widger
Phillip Widger
MHMeirion Hills
Meirion Hills
DMDaniel Mitchard
Daniel Mitchard
In electrical networks, SF6 gas is currently used to insulate high-voltage equipment, however, due to its high environmental impact, new alternatives such as CO2 and electronegative gas mixtures such as CF3I-CO2 are being trialled to replace SF6 and create a sustainable energy system. A high-voltage lightning impulse (1.2 μs/50 μs) was used to approximate the disturbance in a high-voltage electrical network caused by a lightning strike and helped to identify the likely streamer and leader formations in different gases insulating a piece of gas insulated switchgear. In this paper, the theoretical and practical aspects of electrical streamer and leader formations in pure CO2 and an electronegative gas mixture of CF3I-CO2 are examined using schlieren videography in small length rod-plane gas gaps between 20 and 50 mm in length. Schlieren allows the examination of gas density in streamer formations and for the differences in weakly attaching gases, such as CO2, and electronegative gas mixtures, such as CF3I-CO2, to be studied. The gas pressure is varied in order to examine the differences in streamer and leader formation as the gas density is varied and hence the probability of electron collision is varied.

14 March 2026
Verified
Conference Paper
Open access
CMConnor McGurk
Connor McGurk
DPDaniel Peters
Daniel Peters
EMElin McCormack
Elin McCormack
DCDavid Clark
David Clark
MHMeirion Hills
Meirion Hills
DMDaniel Mitchard
Daniel Mitchard
Lightning flashes are a major source of tropospheric NOx, which leads to the production of tropospheric O3 (Elshorbany et al., 2024). Tropospheric O3 is an important greenhouse gas (Skeie et al., 2020), and lightning rates are predicted to increase with global warming (e.g., Pinto & Pinto, 2020; Romps et al., 2014), creating a positive feedback loop. Laboratory-based measurements are a means to improve the parameterisation of this source to improve the accuracy of climate models. We sampled concentrations of NO, NO2 and O3 produced following lightning generated at Cardiff University’s Lightning Laboratory, the only university-based research laboratory of its type in Europe. The laboratory generated D waveforms (peak currents ranging from 10 to 100 kA over 100 µs) and C waveforms (~250 A for 0.5 s) conforming to the EUROCAE ED-84 and its SAE equivalent standards. The D waveform represents the initial impulse and any subsequent restrikes, whereas the C represents the long-duration continuing current seen in ~10% of lightning waveforms (Pérez-Invernón et al., 2023). An array of low-cost sensors recorded gas concentrations following strikes. Despite some disruption due to the lightning Electro-Magnetic Pulse (EMP), and instances where high concentrations have saturated the sensors, initial results demonstrate the feasibility of measuring lightning NOX and O3 generation in the laboratory. This provides a foundation for future developments with a view to better quantifying the impact of lightning strikes on tropospheric chemistry and investigating how this varies with the waveform and power dissipated by the strike. References Elshorbany, Yasin, et al. “Tropospheric Ozone Precursors: Global and Regional Distributions, Trends, and Variability.” Atmospheric Chemistry and Physics, vol. 24, no. 21, 5 Nov. 2024, pp. 12225–12257, acp.copernicus.org/articles/24/12225/2024/?form=MG0AV3, https://doi.org/10.5194/acp-24-12225-2024. J., Osmar Pinto, and Iara R. C. A. Pinto. “Lightning Changes in Response to Global Warming in Rio de Janeiro, Brazil.” American Journal of Climate Change, vol. 09, no. 03, 2020, pp. 266–273, https://doi.org/10.4236/ajcc.2020.93017. Pérez-Invernón, Francisco J., et al. “Variation of Lightning-Ignited Wildfire Patterns under Climate Change.” Nature Communications, vol. 14, no. 1, 10 Feb. 2023, https://doi.org/10.1038/s41467-023-36500-5. Romps, D. M., et al. “Projected Increase in Lightning Strikes in the United States due to Global Warming.” Science, vol. 346, no. 6211, 13 Nov. 2014, pp. 851–854, science.sciencemag.org/content/346/6211/851, https://doi.org/10.1126/science.1259100. Skeie, Ragnhild Bieltvedt, et al. “Historical Total Ozone Radiative Forcing Derived from CMIP6 Simulations.” Npj Climate and Atmospheric Science, vol. 3, no. 1, 17 Aug. 2020, https://doi.org/10.1038/s41612-020-00131-0.

15 March 2025
Verified
Conference Paper
Open access
MBMarrick Braam
Marrick Braam
AHAssaf Hochman
Assaf Hochman
TKThaddeus Komacek
Thaddeus Komacek
DSDenis Sergeev
Denis Sergeev
Yoav Y YairYoav Y Yair
Yoav Y Yair
DMDaniel Mitchard
Daniel Mitchard
Electrical processes such as lightning and transient luminous events (TLEs) are important drivers of chemical processes in planetary atmospheres, including potentially facilitating the formation of important prebiotic molecules. The numerous extrasolar planets discovered present a huge diversity in environmental conditions to explore the possible emergence of electrical processes. To this end, we adapt general circulation models to simulate these exoplanet atmospheres and study the potential emergence of electrical processes. Here, we present results from simulations of tidally locked rocky exoplanets with the Met Office Unified Model. Lightning parameterisations that use bulk cloud properties - such as cloud-top height, frozen water content, and graupel flux - are initially used to infer lightning flash rates. For tidally locked exoplanets, we find that lightning is limited to the permanent dayside hemisphere, with substantial spatial and temporal variations. We then discuss methods to determine the charge structure and thus electric field strengths in the atmospheres, that can be used to infer whether lightning flashes can be followed by TLEs. Finally, we put the electrical processes into context of the atmospheric chemistry and potential observational consequences.

15 March 2025
Verified
Conference Paper
Open access
MHMeirion Hills
Meirion Hills
DMDaniel Mitchard
Daniel Mitchard
NPNicolas Peretto
Nicolas Peretto
To better understand lightning interactions with the atmosphere, a high-speed (streak) spectrograph was used to characterise various high voltage impulses representing lightning. A Marx generator was used to produce 1.2/50 μs high voltage impulses, according to the IEC 60060 standard, ranging from 60 kV to 160 kV. The atomic emission spectrum was captured using a high-speed streak system at resolutions of 0.35 μs/pixel to 0.14 μs/pixel. Spectral data were first recorded over a broad range of 250 to 990 nm, covering a part of the ultraviolet spectrum, full visible spectrum and into near-infrared. Then three smaller bands were chosen for high resolution spectral data to enable the identification of key atomic emission lines such as Oxygen-I, Nitrogen-I and II, and Argon-I from the atmosphere, as well as Tungsten-I from the experiment electrodes. It was observed that an increase in high voltage lead to greater spectral intensity with more prominent lines, as expected, indicating an increase in energy transfer into the surrounding atmosphere. Subsequent analysis of the data resulted in both temperature and energy measurements of these arcs. Such spectral signatures have important implications for refining atmospheric electricity models and better understanding risks associated with lightning, particularly for built infrastructure, such as struck power lines and wind turbines, but also natural features, like forests and woodland. It is the intention that this work will progress onto the study of spectra from laboratory generated lightning arcs.