Meltem Sümbüllü

Dr. Meltem Sümbüllü


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2025 in International Dental Journal
Verified
Journal Article
Open access
MBMine Büker
Mine Büker
MSMeltem Sümbüllü
Meltem Sümbüllü
HAHakan Arslan
Hakan Arslan
Despite the use of artificial intelligence, which is increasingly prevalent in healthcare settings, concerns remain regarding its reliability and accuracy. The study assessed the overall, difficulty level-specific, and day-to-day accuracy and consistency of 5 AI chatbots-ChatGPT-3.5, ChatGPT-4.o, Gemini 2.0 Flash, Copilot, and Copilot Pro-in answering clinically relevant endodontic questions. Seventy-six correct/incorrect questions were developed by 2 endodontists and categorized by an expert into 3 difficulty levels (Basic [B]-, Intermediate [I]-, and Advanced [A]- level]. Twenty questions from each difficulty level were selected from a set of 74 validated questions (B, n = 26; I, n = 24; A, n = 24), resulting in a total of 60 questions. The questions were asked of the chatbots over a period of 4 days, at 3 different times each day (morning, afternoon, and evening). ChatGPT-4.o achieved the highest overall accuracy (82.5%) and perfect performance in the B-level category (95.0%), while Copilot Pro had the lowest accuracy (74.03%). Gemini and ChatGPT-3.5 showed similar overall accuracy. Gemini's accuracy significantly improved over time, whereas significant decreases were noted in the Copilot Pro model across days, and no significant change was detected in both ChatGPT models and Copilot. In the B-level category, while Copilot Pro showed a significant decrease in accuracy rates, and in the B- and I-level categories, Copilot showed a significant increase in accuracy rates over the days. In the A-level category, Gemini demonstrated a significant increase in accuracy rates over the days. ChatGPT-4.o demonstrated superior performance, whereas Copilot and Copilot Pro showed insufficient accuracy. ChatGPT-3.5 and Gemini may be acceptable for general queries but require caution in more advanced cases. ChatGPT-4.o demonstrated the highest overall accuracy and consistency in all question categories over 4 days, suggesting its potential as a reliable tool for clinical decision-making.

7 September 2023 in Journal of Endodontics
Verified
Journal Article
Closed access
MBMine Büker
Mine Büker
MSMeltem Sümbüllü
Meltem Sümbüllü
AAAfzal Ali
Afzal Ali
OÜOğuzhan Ünal
Oğuzhan Ünal
HAHakan Arslan
Hakan Arslan

2 December 2025 in PeerJ
Verified
Journal Article
Open access
PDF file
MSMeltem Sümbüllü
Meltem Sümbüllü
AAAfzal Ali
Afzal Ali
ABAbdulaziz Bakhsh
Abdulaziz Bakhsh
HAHakan Arslan
Hakan Arslan
Background: Bioceramic sealers are increasingly used due to their favorable properties, but their strong bonding to dentin complicates retreatment procedure. In addition, canal irregularities such as isthmuses make the complete removal of filling materials more challenging. Aim: This study aimed to evaluate the retreatability of five bioceramic sealers (BioRoot RCS, Bio-C Sealer, CeraSeal, Endoseal MTA, and AH Plus Bioceramic Sealer) using passive ultrasonic irrigation. Materials and Methods: Sixty human mandibular premolars with straight canals were prepared to size 40/0.04 taper. After longitudinal splitting, standardized grooves were created. The root canals were subsequently obturated using the single cone technique and stored at 37 °C with 100% humidity for 21 days. Passive ultrasonic irrigation was used to assess sealer removal. Statistical analysis was performed with Kruskal–Wallis and Mann–Whitney U tests. Results: The amount of residual sealer in the apical region was statistically higher compared with the coronal region. In the coronal region, the highest amount of residual material was observed in the Bio-C Sealer group, and this difference was statistically significant compared to the other groups. There was no significant difference among the other groups. In the apical region, there were no statistically significant difference between Bio-C Sealer and Endoseal MTA; however Bio-C Sealer showed a statistically significantly higher amount of residual material compared to BioRoot RCS, Ceraseal, and Ah Plus Bioceramic Sealer. Conclusion: Among the evaluated bioceramic sealers, Bio-C Sealer exhibited the highest amount of residual material, particularly in the apical region, indicating its lower retreatability. Passive ultrasonic irrigation improved the removal of BioRoot RCS, CeraSeal, and AH Plus Bioceramic Sealer, but was less effective for Bio-C Sealer and EndoSeal MTA. These findings highlight the variability in retreatability among different bioceramic sealers and emphasize the importance of material selection in cases with potential need for retreatment.


1 January 2022 in Saudi Endodontic Journal
Verified
Journal Article
Open access
AAAfzal Ali
Afzal Ali
MSMeltem Sümbüllü
Meltem Sümbüllü
AIAasima İsHaq
Aasima İsHaq
HAHakan Arslan
Hakan Arslan
Occur to the dentists. An adolescent postgraduate student in the department of conservative dentistry and endodontics, with an ASA physical status I encountered itching, erythema, and swelling of her left-hand skin with the first-time use of AH Plus sealer in her career. A diagnosis of Contact Urticaria was established by the dermatologist upon examination. Topical steroids and antihistamine drugs were advised to the endodontic postgraduate and within a week the symptoms were resolved. The case report focuses attention on handling of epoxy resin-based root canal sealer. The dentists should exercise care and follow manufacturer's instructions while handling the dental materials....

28 March 2025 in Odontology
Verified
Journal Article
Open access
PDF file
OÜOğuzhan Ünal
Oğuzhan Ünal
MSMeltem Sümbüllü
Meltem Sümbüllü
ELEsra Laloğlu
Esra Laloğlu
This study aimed to investigate the effect of tricalcium silicate- and calcium hydroxide-based intracanal dressing on the release of nuclear factor kappa B ligand (RANKL), osteoprotegerin (OPG), tumor necrosis factor-alpha (TNF-α), prostaglandin-E2 (PGE-2), and transforming growth factor-beta (TGF-β) in asymptomatic periapical lesions. The 60 patients included in the study were randomly divided into two groups according to the intracanal dressing. After removing gutta-percha from the root canals, RANKL, OPG, TNF-α, PGE-2, and TGF-β samples were obtained from the apical tissues using three paper cones and the selected dressing material was placed into the canals. In the second appointment, the dressing was removed, and the second samples were taken using the same method. Pre-treatment and post-treatment RANKL, OPG, TNF-α, PGE-2, and TGF-β levels were determined using an enzyme-linked immunosorbent assay test. Data were analysed using t-test, the Mann–Whitney U test, the Wilcoxon test, The Fisher–Freeman–Halton test, and Path analysis. No significant difference was found between the groups in terms of demographic variables (age, gender, tooth region, and smoking) (p > 0.05). There was a statistically significant decrease in RANKL/OPG, TNF-α, PGE-2, and TGF-β levels before and after treatment in both groups (p < 0.05). A significant difference was observed in the percentage change of RANKL/OPG, TNF-α, and TGF-β ratios between the groups (p < 0.05). A statistically higher decrease in RANKL/OPG, TNF-α, and TGF-β levels was observed in the calcium hydroxide-based intracanal dressing group (p < 0.05). No significant difference was observed between the groups in terms of PGE-2 percentage change (p > 0.05). Tricalcium silicate-based intracanal dressing effectively reduced RANKL/OPG, TNF-α, PGE-2, and TGF-β levels in periapical lesions, but calcium hydroxide-based intracanal dressing resulted in a higher percentage reduction in RANKL/OPG, TNF-α, and TGF-β levels. The effects of both medicaments on PGE-2 levels were similar. Trial registration The study was registered in clinical trials database on 12 March 2024 (https://www.clinicaltrials.gov). Registration number: NCT06307678.