Mertcan Koçak

Mr. Mertcan Koçak

Izmir Kâtip Çelebi University, İzmir, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Gait & Posture
Verified
Journal Article
Closed access
MDMert Doğan
Mert Doğan
Mertcan KoçakMertcan Koçak
Mertcan Koçak
ÖKÖzge Onursal Kılınç
Özge Onursal Kılınç
FAFatma Ayvat
Fatma Ayvat
GSGülşah Sütçü
Gülşah Sütçü
SYSibel Aksu Yıldırım
Sibel Aksu Yıldırım

19 February 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ŞMŞenay Mihçin
Şenay Mihçin
SCSamet Ciklacandir
Samet Ciklacandir
Mertcan KoçakMertcan Koçak
Mertcan Koçak
ATAliye Tosun
Aliye Tosun
Human motion capture (MOCAP) systems are vital while determining the loads occurring at the joints. Most of the clinical MOCAP systems are very costly, requiring investment and infrastructure. Therefore, alternative technologies are in demand. In this study, a novel markerless wearable MOCAP system was assessed for its compatibility with a biomechanical modeling software. To collect evidence, experiments were designed in two stages for quantifying the range of motion (ROM) of the hip joint, in vitro and in vivo. Three constrained single-plane motions—abduction/adduction, flexion/extension, and internal/external rotation movements of the active leg—were analyzed. The data were collected from 14 healthy volunteers, using the wearable system and a medical grade optoelectronic MOCAP system simultaneously and compared against. For the in vitro study, the root-mean-square error (RMSE) for the abduction/adduction motion of the hip joint was calculated as 0.11 deg/0.30 deg and 0.11 deg/0.09 deg, respectively, for the wearable and the opto-electronic system. The in vivo Bland–Altman plots showed that the two system data are comparable. The simulation software is found compatible to run the simulations in offline mode. The wearable system could be utilized in the field of biomechanics software for running the kinetic simulations. The results demonstrated that the wearable system could be an alternative in the field of biomechanics based on the evidence collected.

23 March 2022 in HardwareX
Verified
Journal Article
Open access
Mertcan KoçakMertcan Koçak
Mertcan Koçak
EGErkin Gezgin
Erkin Gezgin
This study introduces a compact low-cost single degree of freedom end-effector type upper arm rehabilitation system (PARS) along with its hardware and software elements. Proposed system is also suitable to be used in conjunction with a gaming environment. Throughout the study structural setup of the system was explained in detail along with its electronics, control system and gaming software. Introduced virtual gaming interface supports various game levels with different difficulties generated via interaction type control algorithms. Having simple structural design constructed by using basic available components, proposed system can be easily manufactured and utilized in physical rehabilitation procedures by using supplied open source codes. Introduced systems compactness and user friendly interface also allow its usage for individual home therapies for remote rehabilitation treatment procedures.

31 December 2024 in Machines
Verified
Journal Article
Open access
PDF file
Mertcan KoçakMertcan Koçak
Mertcan Koçak
EGErkin Gezgin
Erkin Gezgin
This study introduces a novel single-degree-of-freedom polycentric knee mechanism specifically designed for transfemoral prostheses to address dual challenges of stability during the stance phase and biomimetic motion during the swing phase. Leveraging analytical kinematic synthesis, the proposed mechanism integrates separate kinematic designs for each of the gait phases into a combined structure that prevents singularity issues during full knee flexion, which is a significant limitation in conventional active designs. The stance phase mechanism emphasizes stability through precise control of the instantaneous center of rotation (ICR) and weight-bearing support, while the swing phase mechanism adopts a biomimetic motion trajectory. In order to validate the proposed methodology, kinematic synthesis, numerical simulations, and visual analyses were conducted. Incorporating insights from polycentric prostheses and orthotic applications, the proposed mechanism achieves a seamless transition between two different configurations by keeping its overall mobility. Additionally, its possible compatibility with motorized actuation offers a foundation for active prosthesis systems, paving the way for adapting the advantages of polycentric prosthesis to active devices. This innovative approach offers a scientifically grounded pathway for improving transfemoral prosthetic systems, advancing both their biomechanical utility and user comfort.

23 July 2024 in Journal of Mechanical Design
Verified
Journal Article
Closed access
MYMustafa Volkan Yazıcı
Mustafa Volkan Yazıcı
Mertcan KoçakMertcan Koçak
Mertcan Koçak
TUTugrul Uslu
Tugrul Uslu
EGErkin Gezgin
Erkin Gezgin
This article focuses on the design procedures of Alizade's direct and Gezgin's inverse structural synthesis methodologies for platform type manipulators. These task-based synthesis procedures include versatile methodologies for any designer to generate various platform-type manipulators with respect to given constraints via simple universal mobility formulation. However, they rely on the manual generation of mobility-independent coarse topological structures, where it is nearly impossible to generate all possible results. In light of this, the current study introduces a unique connection-based adjacency matrix (CAM) for topology representation, in which legs connected to the fixed ground and platform connections (hinges and branches) are treated separately. The main objective of CAM is to ensure an efficient transition from manual topology generation to automated methods by providing compatibility with software algorithms to describe topologies. Throughout the article, CAM-based automated topology generation algorithm that reveals all possible unique coarse topologies with respect to given design constraints is also presented along with examples. Introduced algorithm both allows investigation of isomorphism and eliminates necessity of inversion.

28 September 2022 in Biomimetics
Verified
Journal Article
Open access
PDF file
Mertcan KoçakMertcan Koçak
Mertcan Koçak
Mustafa Volkan YAZICIMustafa Volkan YAZICI
Mustafa Volkan YAZICI
EAEFECAN AKDAL
EFECAN AKDAL
FCFatih Cemal Cemal Can
Fatih Cemal Cemal Can
EGErkin Gezgin
Erkin Gezgin
Throughout history, humans have observed living or non-living things in nature and then imitated them in relation to these observations. This is due to the fact that the energy found in nature is generally consumed at an optimal level in order for it to endure. Biomimetic inspiration in many designs and applications is widely displayed, including within the field of engineering. In this paper, we were inspired by the double set of jaws found in the moray eel, which gives this fish a huge advantage while hunting, with a mobile pharyngeal jaw that works together with its oral jaw in order to overcome ineffective suction capabilities. A procedure that mimics the hunting motion of the moray eel was utilized by considering the overall movement as a single degree of freedom with multiple outputs on account of the repeating motion that is required during hunting. This procedure includes structural and dimensioning synthesis, wherein the latter was utilized with analytic kinematic synthesis for each linkage transfer. The flexibilities in parameters were taken into account with a novel multiple iterative kinematic synthesis algorithm that resulted in various mechanisms with the same purpose. Among the excessive number of resultant mechanisms, the optimization was carried out by considering the highest torque transmission ratio at critical timings that were specified as bio-constraints. In the end, the kinematic movement validation was utilized.