Michael Stickels

Mr. Michael Stickels


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RPRomir P Parmar
Romir P Parmar
ACAustin Cronen
Austin Cronen
CHClayton Hui
Clayton Hui
Michael StickelsMichael Stickels
Michael Stickels
ELEvan Lederman
Evan Lederman
ASAnup Shah
Anup Shah
Background/Objectives: Testosterone replacement therapy (TRT) has become increasingly common, particularly for patients with symptomatic hypogonadism or individuals undergoing gender-affirming therapy. The current literature is inconclusive on the association between TRT and orthopedic surgery. This study sought to examine outcomes of reverse total shoulder arthroplasty (RSA) in patients receiving TRT. Methods: A retrospective cohort of RSA patients from 2010 to 2022 was queried using the PearlDiver database. Patients were included if they underwent RSA with at least 2 years of follow-up. Patients who underwent at least 90 days of TRT prior to their surgery were matched by Charlson Comorbidity Index, age, and gender to a control cohort. Univariate analysis using chi-squared tests and Student’s t-tests were used to compare demographics outcomes between groups. Results: A total of 1906 patients were identified who used TRT within 90 days of undergoing RSA, and these patients were matched to a control cohort of 1906 patients. Patients who used TRT within 90 days did not have significantly different rates of revision RSA (12.01%) compared to those without use (11.02%) (p = 0.335). Furthermore, between the TRT group and the control group, PJI rates (1.42% vs. 1.63%; p = 0.597) and periprosthetic fracture rates (0.58% vs. 1.05%, p = 0.105) were not significantly different. Conclusions: This study demonstrated that TRT use within 90 days of RSA does not increase the rates of revision, fracture, or infection. These results can assist surgeons when evaluating patients on TRT who also may be candidates for RSA.

1 October 2025 in Foot & Ankle Orthopaedics
Verified
Journal Article
Open access
Michael StickelsMichael Stickels
Michael Stickels
MSMatthew Scheller
Matthew Scheller
DVDavid Vier
David Vier
DJDavid E. Jaffe
David E. Jaffe
Background: Despite the safety and versatility of circular external fixators (CEFs) for many indications, there is limited information on their contemporary usage and the factors contributing to their potential underutilization. This study aims to estimate the prevalence of contemporary CEF use, characterize barriers to adoption, and identify potential solutions among American Orthopaedic Foot & Ankle Society (AOFAS) members. Methods: A multibranched survey was designed for distribution to all active practicing members of the AOFAS to collect data on demographics, training background, CEF usage profile, provider opinions, barriers to device adoption, and factors that could encourage greater use. Data were collected through Qualtrics XM. Statistical analysis analyzing respondent differences included descriptive statistics, χ 2 tests for independence, and unpaired t tests. Results: Of 169 participants, 27.81% reported not using CEFs in their practice despite 94.08% of respondents agreeing that their use is critical for certain patients. Overall, 70.21% of nonusers believed it could have a role in their practice but had hesitations. In addition, 59.76% of participants received minimal to no exposure in residency, and this was a significant predictor for current usage ( P = .0119). CEFs are most commonly used for Charcot neuroarthropathy (86.07%), infection management (83.60%), and other deformity corrections (65.67%). Nonusers are more likely to believe CEFs take too long to assemble intraoperatively, express greater concern about postoperative burden, and are less confident in postoperative care compared to users (all P < .01). The most popular interventions that would facilitate usage were access to longitudinal mentorship, further technological advancement, and attending non–industry-sponsored courses. Conclusion: Perceived lengthy operative time, postoperative burden, and lack of postoperative management confidence were predominant reasons for the lack of CEF use. This survey suggests that these barriers could be addressed by more exposure during training, attending non–industry-sponsored courses, and longitudinal mentorship. Level of Evidence: Level IV, cross-sectional study.

23 May 2025 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
Michael StickelsMichael Stickels
Michael Stickels
AVArjun Vohra
Arjun Vohra
JWJackson Woodrow
Jackson Woodrow
YGYoussef Galal
Youssef Galal
CCCole Cook
Cole Cook
ASAnup Shah
Anup Shah
Purpose: To evaluate variation in quadriceps tendon (QT) morphology in cadaveric specimens, focusing on tendon thickness, and to improve current QT harvesting techniques and graft preparation for anterior cruciate ligament (ACL) reconstruction. Methods: Eight fresh‐frozen, skeletally mature, midthigh‐to‐toe cadaveric legs with no history of knee surgery and at least 65 mm of tendon were utilized. There were 4 males and 4 females. The average donor age was 80.4 years (range, 69‐93 years), and the average height was 66.1 inches (range, 59 to 72 inches). The tendon was exposed with an open extensile approach via a longitudinal midline incision. Tendon thickness was measured using calipers at the superior pole of the patella and 65 mm proximal to the insertion. Univariate analysis was used to generate sample means, standard deviations, and 95% confidence intervals (CIs). Results: Tendon thickness at the distal patellar insertion site was a mean (standard deviation [SD]) of 8.7 (1.4) mm. At 65 mm proximal to the patellar insertion site, the mean (SD) thickness of the tendon was 6.5 (1.1) mm. The 95% CIs were 7.7 to 9.7 mm for the distal insertion and 5.8 to 7.2 mm for the proximal tendon. The 2 measurement sites had a mean (SD) difference of 2.2 (0.7) mm (95% CI, 1.6‐2.8 mm; P < .001). Overall, the proximal tendon showed a reduction in thickness by a mean (SD) of 25.3% (6.7%) compared to the thickness at the patellar pole. Conclusions: Quadriceps tendons had a significant decrease in thickness, measuring distally to proximally. However, the thickness was not uniform, and the variation was high among specimens tested. Clinical Relevance: Anatomic variations in QT thickness may contribute to variable graft diameters in ACL reconstruction, highlighting the importance of accounting for tendon morphology for graft preparation, ACL tunnel position, and size.

5 January 2026 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
Michael StickelsMichael Stickels
Michael Stickels
BBBrett Brazier
Brett Brazier
RPRomir P Parmar
Romir P Parmar
ACAustin Cronen
Austin Cronen
CHClayton Hui
Clayton Hui
ASAnup Shah
Anup Shah
Background: It has been demonstrated that exogenous testosterone can lead to higher rates of tendinous rupture and that injectable testosterone replacement therapy (TRT) is associated with more systemic complications. While this is the case, there are few studies exploring associations between injectable TRT and complications after anterior cruciate ligament reconstruction (ACLR) surgery. Purpose/Hypothesis: The purpose of this study is to evaluate the association between preoperative injectable TRT and ACLR revision surgery. It was hypothesize that ACLR revision surgery rates will be higher in patients undergoing TRT preoperatively compared with a matched cohort. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective cohort of patients who underwent ACLR between 2015 and 2022 was obtained through the PearlDiver Database (Mariner). Patients with a history of ACLR, 2 years of follow-up, and injectable TRT use before ACLR were identified using International Classification of Diseases, 10th Revision, and Current Procedural Terminology codes. Three TRT usage intervals were analyzed to evaluate ACLR revision rates in those with usage of injectable TRT compared with those with propensity score–matched demographics and Charlson Comorbidity Index with no history of injectable TRT use who underwent ACLR. Cohorts were via univariate analysis, chi-square tests, Student t tests, and log-rank tests. Results: TRT use ≤1 year before primary ACLR surgery demonstrated a 17.05% (66/387; mean age, 40.3) ACLR revision rate compared with 5.17% (20/387; mean age, 40.8) in the matched cohort control group ( P < .001), yielding a relative risk of revision surgery of 3.30 (95% CI, 2.04-5.33). Statistical analysis for distant TRT use >1 year before surgery (n = 160) was underpowered but supported trends toward increased revision risk with TRT exposure with a 14.38% revision rate (n = 23). TRT users with any exposure before or after surgery (n = 2614) had similar revision rates (n = 168; 6.36%) compared with the control group (n = 164; 6.21%); the difference was not significant ( P = .82). Conclusion: Our study demonstrated that injectable TRT use within 1 year of primary ACLR is associated with a >3-fold increase in ACLR revision rates with 2 years of follow-up. Physicians should consider incorporating this increased risk into patient counseling during shared decision-making discussions, as this correlation may influence clinical and surgical decision making for patients with previous ACLR.

29 May 2025 in Children
Verified
Journal Article
Open access
PDF file
Michael StickelsMichael Stickels
Michael Stickels
KRKyung Min Roh
Kyung Min Roh
MBMeghana Belthur
Meghana Belthur
MBMohan V Belthur
Mohan V Belthur
Background: Reamer–irrigator–aspirators (RIAs) are newer orthopedic devices intended to harvest bone while minimizing complications associated with traditional harvesting techniques. Its high success rate has resulted in relatively few studies on its intraoperative and postoperative complications, especially in pediatric populations. This study provides a scoping review of complications associated with the RIA and presents an institutional case series of RIA complications. Materials and Methods: The scoping review was conducted via modified Joanna Briggs Institute (JBI) guidelines. Cases at a single institution were selected on an individual basis as they occurred during or after RIA-associated surgeries. Results: Our case series consists of three males and one female, ranging from 8 to 14 years old, with varying comorbid orthopedic conditions. All complications occurred intraoperatively, with three instances of retained hardware and one instance of cortical disruption. Each complication was classified as stage I according to the modified Clavien–Dindo–Sink classification system. There were no long-term sequelae despite limited management. A scoping review of the literature revealed extremely limited data on pediatric complications, but several mechanical and clinical complications have been described. Conclusions: Complications associated with RIA use in children appear to be inconsequential, but data are very sparse, and further studies are required.