Miguel Hernandez-Cabronero

Dr. Miguel Hernandez-Cabronero

Universitat Autònoma de Barcelona
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2017 in Information
Verified
Journal Article
Open access
PDF file
FLFeng Liu
Feng Liu
MHMiguel Hernandez-Cabronero
Miguel Hernandez-Cabronero
VSVictor Sanchez
Victor Sanchez
MMMichael W. Marcellin
Michael W. Marcellin
ABAli Bilgin
Ali Bilgin
With the increasing utilization of medical imaging in clinical practice and the growing dimensions of data volumes generated by various medical imaging modalities, the distribution, storage, and management of digital medical image data sets requires data compression. Over the past few decades, several image compression standards have been proposed by international standardization organizations. This paper discusses the current status of these image compression standards in medical imaging applications together with some of the legal and regulatory issues surrounding the use of compression in medical settings.

10 February 2021 in IEEE Geoscience and Remote Sensing Magazine
Verified
Journal Article
Closed access
MHMiguel Hernandez-Cabronero
Miguel Hernandez-Cabronero
AKAaron B. Kiely
Aaron B. Kiely
MKMatthew Klimesh
Matthew Klimesh
IBIan Blanes
Ian Blanes
JLJonathan Ligo
Jonathan Ligo
JSJoan Serra-Sagrista
Joan Serra-Sagrista
The Consultative Committee for Space Data Systems (CCSDS) published the CCSDS 123.0-B-2, “Low-Complexity Lossless and Near-Lossless Multispectral and Hyperspectral Image Compression” standard. This standard extends the previous issue, CCSDS 123.0-B-1, which supported only lossless compression, while maintaining backward compatibility. The main novelty of the new issue is support for near-lossless compression, i.e., lossy compression with user-defined absolute and/or relative error limits in the reconstructed images. This new feature is achieved via closed-loop quantization of prediction errors. Two further additions arise from the new near-lossless support: first, the calculation of predicted sample values using sample representatives that may not be equal to the reconstructed sample values, and, second, a new hybrid entropy coder designed to provide enhanced compression performance for low-entropy data, prevalent when nonlossless compression is used. These new features enable significantly smaller compressed data volumes than those achievable with CCSDS 123.0-B-1 while controlling the quality of the decompressed images. As a result, larger amounts of valuable information can be retrieved given a set of bandwidth and energy consumption constraints.

17 August 2017 in IEEE Transactions on Multimedia
Verified
Journal Article
Closed access
MHMiguel Hernandez-Cabronero
Miguel Hernandez-Cabronero
MMMichael W. Marcellin
Michael W. Marcellin
IBIan Blanes
Ian Blanes
JSJoan Serra-Sagrista
Joan Serra-Sagrista
Digital cameras have become ubiquitous for amateur and professional applications. The raw images captured by digital sensors typically take the form of color filter array (CFA) mosaic images which must be “developed” (via digital signal processing) before they can be viewed. Photographers and scientists often repeat the “development process” using different parameters to obtain images suitable for different purposes. Since the development process is generally not invertible it is commonly desirable to store the raw (or undeveloped) mosaic images indefinitely. Uncompressed mosaic image file sizes can be more than 30 times larger than those of developed images stored in JPEG format. Thus data compression is of interest. Several compression methods for mosaic images have been proposed in the literature. However they all require a custom decompressor followed by development-specific software to generate a displayable image. In this paper a novel compression pipeline that removes these requirements is proposed. Specifically mosaic images can be losslessly recovered from the resulting compressed files and more significantly images can be directly viewed (decompressed and developed) using only a JPEG 2000 compliant image viewer. Experiments reveal that the proposed pipeline attains excellent visual quality while providing compression performance competitive to that of state-of-the-art compression algorithms for mosaic images.

11 June 2019 in Remote Sensing
Verified
Journal Article
Open access
PDF file
IBIan Blanes
Ian Blanes
AKAaron Kiely
Aaron Kiely
MHMiguel Hernandez-Cabronero
Miguel Hernandez-Cabronero
JSJoan Serra-Sagrista
Joan Serra-Sagrista
This article studies the performance impact related to different parameter choices for the new CCSDS-123.0-B-2 Low-Complexity Lossless and Near-Lossless Multispectral and Hyperspectral Image Compression standard. This standard supersedes CCSDS-123.0-B-1 and extends it by incorporating a new near-lossless compression capability, as well as other new features. This article studies the coding performance impact of different choices for the principal parameters of the new extensions, in addition to reviewing related parameter choices for existing features. Experimental results include data from 16 different instruments with varying detector types, image dimensions, number of spectral bands, bit depth, level of noise, level of calibration, and other image characteristics. Guidelines are provided on how to adjust the parameters in relation to their coding performance impact.

3 July 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
MHMiguel Hernandez-Cabronero
Miguel Hernandez-Cabronero
VSVictor Sanchez
Victor Sanchez
IBIan Blanes
Ian Blanes
FAFrancesc Auli-Llinas
Francesc Auli-Llinas
MMMichael W. Marcellin
Michael W. Marcellin
JSJoan Serra-Sagrista
Joan Serra-Sagrista
The use of whole-slide images (WSIs) in pathology entails stringent storage and transmission requirements because of their huge dimensions. Therefore, image compression is an essential tool to enable efficient access to these data. In particular, color transforms are needed to exploit the very high degree of inter-component correlation and obtain competitive compression performance. Even though state-of-the-art color transforms remove some redundancy, they disregard important details of the compression algorithm applied after the transform. Therefore, their coding performance is not optimal.We propose an optimization method called Mosaic Optimization for designing irreversible and reversible color transforms simultaneously optimized for any given WSI and the subsequent compression algorithm. Mosaic Optimization is designed to attain reasonable computational complexity and enable continuous scanner operation. Exhaustive experimental results indicate that, for JPEG 2000 at identical compression ratios, the optimized transforms yield images more similar to the original than other state-of-the-art transforms. Specifically, irreversible optimized transforms outperform the Karhunen-Lo`eve Transform (KLT) in terms of PSNR (up to 1.1 dB), the HDR-VDP-2 visual distortion metric (up to 3.8 dB) and accuracy of computer-aided nuclei detection tasks (F1 score up to 0.04 higher). Additionally, reversible optimized transforms achieve PSNR, HDR-VDP-2 and nuclei detection accuracy gains of up to 0.9 dB, 7.1 dB and 0.025, respectively, when compared to the reversible color transform (RCT) in lossy-to-lossless compression regimes.

18 April 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
VSVictor Sanchez
Victor Sanchez
MHMiguel Hernandez-Cabronero
Miguel Hernandez-Cabronero
The increasing availability of digital pathology images has motivated the design of tools to foster multidisciplinary collaboration among researchers, pathologists, and computer scientists. Telepathology plays an important role in the development of collaborative tools, as it facilities the transmission and access of pathology images by multiple users. However, the huge ?le size associated with pathology images usually prevents full exploitation of the collaborative telepathology system potential. Within this context, rate control (RC) is an important tool that allows meeting storage and bandwidth requirements by controlling the bit rate of the coded image. In this paper, we propose a novel graph-based RC algorithm with lossless region of interest (RoI) coding for pathology images. The algorithm, which is designed for block-based predictive transform coding methods, compresses the non-RoI in a lossy manner according to a target bit rate and the RoI in a lossless manner. It employs a graph where each node represents a constituent block of the image to be coded. By incorporating information about the coding cost similarities of blocks into the graph, a graph kernel is used to distribute a target bit budget among the non-RoI blocks. In order to increase RC accuracy, the algorithm uses a rate-lambda (R-λ) model to approximate the slope of the rate-distortion curve of the non-RoI, and a graph-based approach to guarantee that the target bit rate is accurately attained. The algorithm is implemented in the HEVC standard and tested over a wide range of pathology images with multiple RoIs. Evaluation results show that it outperforms other state-of-the-art methods designed for single images by very accurately attaining the target bit rate of the non-RoI.