Trung Nguyen

Mr. Trung Nguyen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2025 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
NLNghia Trong Le
Nghia Trong Le
KNKien Trung Nguyen
Kien Trung Nguyen
TNTrung Nguyen
Trung Nguyen
Prefabricated vertical drain (PVD) combined with vacuum-surcharge preloading is a widely used ground improvement technique to accelerate the dissipation of excess pore water pressure and reduce the soil compressibility. However, difficulties in the numerical simulations of water dissipation and equivalent permeability of soil with PVDs in three-dimensional (3D) and two-dimensional (2D) settings cause substantial deviation of numerical results from observational data. Moreover, the optimum length of PVDs has not been well documented. Accordingly, this work analyzes a project in Dong Nai, Vietnam, where a 37-meter-thick soft soil was treated with PVDs and vacuum-surcharge preloading. In this work, the field observations and finite element method with consolidation theory were used to analyze the ground settlements, lateral displacements, and excess pore water pressure. The observed and simulated data shows that (i) the rate of settlements in the first 60 days of increasing preloading pressure is about 2.1 times faster than that in the next 110 days of constant preloading pressure, (ii) at 170 days, the ground-surface lateral displacement at the toe of the embankment is around 50 mm and reaches its maximum value of 150 mm at 1.55 m depth, and (iii) the dissipation of pore water pressure is closely correlated with the settlement rate. Moreover, back analysis indicates that a permeability conversion ratio from 1.872 to 4.538 should be applied to achieve the same degree of consolidation between 3D and 2D models. Lastly, the optimum length of PVDs in this project is 28 m, around 76% of the fully penetrated length into the soft layer.

12 December 2023
Verified
Book Chapter
Closed access
PDF file
HTHoang The Thao
Hoang The Thao
LVLe Ba Vinh
Le Ba Vinh
THTo Le Huong
To Le Huong
BTBui Quang Thai
Bui Quang Thai
TNTrung Nguyen
Trung Nguyen
HHHoang Long Hai
Hoang Long Hai




11 April 2025 in Tạp chí Vật liệu và Xây dựng - Bộ Xây dựng
Verified
Journal Article
Closed access
NLNghia Trong Le
Nghia Trong Le
KNKien Trung Nguyen
Kien Trung Nguyen
TNTrung Nguyen
Trung Nguyen
Việc dự báo chính xác độ lún cố kết sơ cấp và thứ cấp trong nền đất mềm bão hòa là yếu tố then chốt trong thiết kế xử lý nền đất yếu. Nghiên cứu này cho thấy kết quả mô phỏng phần tử hữu hạn (FEM) 2D và 3D cho phương pháp gia tải trước kết hợp hút chân không và bấc thấm (PVD) cùng với việc sử dụng hai mô hình đất Soft Soil (SS) và Soft Soil Creep (SSC). Kết quả cho thấy, việc sử dụng mô hình đất có xét đến từ biến cho độ lún bề mặt tương đồng với kết quả quan trắc thực tế, trong khi mô hình đất yếu bỏ qua lún thứ cấp do từ biến dẫn đến có sự sai lệch về kết quả đánh giá. Mô hình cũng góp phần khẳng định độ lún thứ cấp do từ biến ảnh hưởng nhiều đến kết quả bài tính xử lý nền. Sự so sánh giữa kết quả của mô hình 2D và 3D càng khẳng định tầm quan trọng của việc hiệu chỉnh hệ số thấm khi chuyển từ bài toán đối xứng trục sang bài toán phẳng để đảm bảo độ chính xác mô hình và hiệu quả kinh tế - kỹ thuật trong xử lý nền đất yếu bằng bấc thấm kết hợp với gia tải trước và bơm hút chân không.