Mirosław Dechnik

Dr. Mirosław Dechnik

Małopolska Center of Energy Efficient Building, Cracow University of Technology, Kraków, Małopolskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2017 in Journal of Building Physics
Verified
Journal Article
Closed access
ARA Romanska-Zapala
A Romanska-Zapala
MBM Bomberg
M Bomberg
MFM Fedorczak-Cisak
M Fedorczak-Cisak
MFM Furtak
M Furtak
DYD Yarbrough
D Yarbrough
Mirosław DechnikMirosław Dechnik
Mirosław Dechnik
The quest for a sustainable built environment brought dramatic changes to architectural design because of the integrated design process. The integrated design process is the modern way to realize “performance architecture,” that is, design with a view to field performance. Integrated design process permits merging of concepts from passive-house designs, solar engineering, and an integration of the building enclosure with mechanical services. In part 1 of this series, the emergence of many new multi-functional materials was discussed. Yet, current innovation is guided by lessons from history. Thermal mass in heavy masonry buildings allowed periodic heating. The authors postulate integration of a hydronic heating system with the walls and the use of smart temperature control of the heating system to modify and optimize the thermal mass contribution. To use the mass of a building, one must accept transient temperature conditions where the indoor temperature varies but is confined by comfort requirements for both summer and winter conditions. On the other side, resiliency requirements dictate that in the absence of electricity the air temperature does not fall below about 12°C over a period of several hours. This requirement implies that summer cooling will likely be separated from the heating systems and that operation of a low-energy building is heavily dependent on the design of smart control systems. Analysis of control systems provided in this article for earth-to-air heat exchangers and cooling of houses with lightweight walls lead us to the requirements of separation between heating and ventilation and needs for different sources of fresh air. Finally, a new concept emerges.

19 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
Anna RomanskaAnna Romanska
Anna Romanska
Mark BombergMark Bomberg
Mark Bomberg
Mirosław DechnikMirosław Dechnik
Mirosław Dechnik
MFMalgorzata Fedorczak-Cisak
Malgorzata Fedorczak-Cisak
MFMarcin Furtal
Marcin Furtal
The growing popularity of buildings with integrated sub-systems requires a review of methods to optimize the preheating of ventilation air. An integrated system permits using geothermal heat storage parallel to the direct outdoor air intake with additional treatment in the mechanical room as a part of building an automatic control system. The earth–air heat exchanger (EAHX) has many advantages but also has many unanswered questions. Some of the drawbacks are: A possible entry of radon gas, high humidity in the shoulder seasons, and the need for two different air intake sources with a choice that depends on the actual weather conditions. In winter the EAHX may be used continuously to ensure thermal comfort, while in other seasons its operation must be automatically controlled. To generate missing information about EAHX technology we examined two nearly identical EAHX systems, one placed in the ground next to a building and the other under the basement slab. In another project, we reinforced the ground storage action by having a heat exchanger placed on the return pipes of the hydronic heating system. The information provided in this paper shows advantages of merging both these approaches, while the EAHX could be placed under the house or near the basement foundation that is using an exterior basement insulation.

24 February 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
Anna RomanskaAnna Romanska
Anna Romanska
MFMarcin Furtak
Marcin Furtak
MFMalgorzata Fedorczak-Cisak
Malgorzata Fedorczak-Cisak
Mirosław DechnikMirosław Dechnik
Mirosław Dechnik
One of the ways to improve the energy balance of buildings is through the use of local, renewable energy sources, for example, ground air heat exchanger. This article continues the study on improving energy efficiency of an EAHX working in cooperation with a ventilation unit. In the previously reported study (Romańska-Zapała et al., 2017), performed during the summer of 2016, it was found that in the summer, the continuous operation of these exchangers is not optimal. Furthermore, there is a need for dynamic control of the ventilation unit's fresh air source. This is due to changes in the exchanger's operating status between heating and cooling, as a result of external temperature fluctuations. This article presents the results of in situ measurements of the horizontal, tubular EAHX which supports maintaining the desired temperature in a building by preheating or precooling the inlet air of the cooperating ventilation unit during transitional seasons of the climatic conditions of southern Poland. In particular, this article provides details on the experimental verification of the 2017 thesis regarding the ineffective work of an EAHX during transitional seasons. The influence of the exchanger on changes in the ventilation unit's inlet air temperature is presented. Numerous, unfavorable changes were registered in the state of the exchanger's work, either heating or cooling the flowing air, depending on the relation of outside air temperature to the achieved output air temperature. This indicated that the work of the exchanger was ineffective for buildings. The key to optimal, energy efficient EAHX – ventilation unit system operation during transitional seasons is the dynamic selection of a fresh air source depending on external conditions and the required output air temperature of the ventilation unit (air supplied to rooms), accounting for the increase of electric energy consumption for the fan drive during EAHX operation.

1 October 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
Anna RomanskaAnna Romanska
Anna Romanska
MFMarcin Furtak
Marcin Furtak
Mirosław DechnikMirosław Dechnik
Mirosław Dechnik
Renewable energy sources are used in the modern energy-efficient buildings to improve their energy balance. One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger - EAHX). This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air. The article presents the results of "in situ" measurements of pipe ground air heat exchanger cooperating with the air handling unit, supporting cooling the building in the summer season, in Polish climatic conditions. The laboratory consists of a ventilation unit intake - exhaust with rotor for which the source of fresh air is the air intake wall and two air intakes field cooperating with the tube with ground air heat exchangers. Selection of the source of fresh air is performed using sprocket with actuators. This system is part of the ventilation system of the Malopolska Laboratory of Energy-Efficient Building (MLBE) building of Cracow University of Technology. The measuring system are, among others, the sensors of parameters of air inlets and outlets of the heat exchanger channels EAHX and weather station that senses the local weather conditions. The measurement data are recorded and archived by the integrated process control system in the building of MLBE. During the study measurements of operating parameters of the ventilation unit cooperating with the selected source of fresh air were performed. Two cases of operation of the system: using EAHX heat exchanger and without it, were analyzed. Potentially the use of ground air heat exchanger in the mechanical ventilation system can reduce the energy demand for heating or cooling rooms by the pre-adjustment of the supply air temperature. Considering the results can be concluded that the continuous use of these exchangers is not optimal. This relationship is appropriate not only on an annual basis for the transitional periods (spring and autumn), but also in individual days in the potentially most favorable periods of work exchanger (summer and winter). Inappropriate operation of the heat exchanger, will lead to a temporary increase in energy consumption for the preparation of the desired air temperature, relative to the fresh air unit which is non-pretreated. For optimal energy system operation: exchanger EAHX - air handling unit, to preserve the most favourable parameters of inlet air to handling unit, there is a need to dynamically adjust the source of fresh air, depending on changing external conditions and the required outlet temperature of central unit (temperature of air forced to the rooms).

24 February 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
Anna RomanskaAnna Romanska
Anna Romanska
MFMarcin Furtak
Marcin Furtak
MFMalgorzata Fedorczak-Cisak
Malgorzata Fedorczak-Cisak
Mirosław DechnikMirosław Dechnik
Mirosław Dechnik
Renewable energy sources have a significant impact on improving a building's energy balance. These sources are increasingly used in modern construction. One such source is a ground air heat exchanger (earth-air heat exchanger – EAHX), which is used in a building's mechanical ventilation system. This solution allows for the initial preparation of inlet air in a ventilation unit prior to the exhaust air energy recovery process (recuperation). As a result, the solution reduces the energy demand for the heating or cooling of rooms. This article expands upon a previous study on the possibilities of improving energy efficiency of a horizontal earth-air heat exchanger (EAHX) working in cooperation with a ventilation unit. This study adds to the knowledge gained in the previous study (Romańska-Zapała et al., 2017) performed during the summer of 2016. This previous study found that, in the summer, the continuous operation of these exchangers is not optimal; therefore, there is a need for dynamic control of the ventilation unit's fresh air source. This is due to changes in the exchanger's operating status between heating and cooling, as a result of external temperature fluctuations. The thesis statement of this previous paper emphasized that this relationship is not only appropriate on an annual basis for the transitional seasons (spring and autumn), but also on individual days during the potentially most favorable seasons of exchanger work (summer and winter). This article presents the results of in situ measurements of the horizontal, tubular ground air heat exchanger which supports building heating by preheating the inlet air of the cooperating ventilation unit in the winter season, in southern Polish climatic conditions. In particular, this article provides details on the experimental verification of the previous paper's thesis regarding the possibility of sub-optimal performance of an EAHX exchanger subject to continuous operation during the winter season. The experiment in this paper was performed using a ventilation unit (intake – exhaust) connected to three independent fresh air sources: a direct external air intake located on the wall, and two air intakes located outside of the building that directs air into the pipes of two earth-air heat exchangers. This article illustrates how the exchanger's work changes the ventilation unit's inlet air temperature. For a majority of the experiment, the exchanger – ventilation unit system was working optimally. Therefore, the system did not require intervention of the control system. However, due to several temporary increases in outdoor temperature, the occasional cooling state operation of the EAHX exchanger was also recorded. Even before the occurrence of these undesirable states, an exchanger should be switched off and a bypass should be used to directly collect external air and reduce the unnecessary load of electric fan drives. Considering the results of this study, it can be concluded that in the winter, it is favorable to automatically control the selection of a ventilation unit's fresh air source depending on external conditions. However, in the winter, the energy effect of the control is comparatively lower than in the summer.

6 September 2019 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
MDMarek Dudzik
Marek Dudzik
Mirosław DechnikMirosław Dechnik
Mirosław Dechnik
MFMarcin Furtak
Marcin Furtak
This paper will continue application of neural networks to the concept of environmental quality management technology described elsewhere. Human preferences are different and may vary depending on type of the work or psycho-physical conditions of workers. This paper deals with application of artificial neural networks (ANNs) to control of general lighting systems to provide personal (individual) illuminance on worktables. Two-layer feedforward ANN is used to identify and model the system. Introduction of ANN to model illumination systems opens a new possibility of individual control systems in which specific areas have different set of requirements than remaining areas of a lighting system.