Monalisa Pattnaik

Dr. Monalisa Pattnaik

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JMJyotismita Mishra
Jyotismita Mishra
Monalisa PattnaikMonalisa Pattnaik
Monalisa Pattnaik
SSSusovon Samanta
Susovon Samanta
This paper proposes a drift free perturb and observe (P&O) maximum power point tracking (MPPT) algorithm for a self-excited induction generator based stand-alone wind energy generation system (WEGS). Conventional P\&O algorithm gives more steady-state oscillation and fails to detect correct direction during wind speed increase condition. To avoid this, the proposed algorithm uses additional dc-link current information for the steady-state as well as transient condition which also decreases the power oscillation around MPP. During sudden wind speed change, the tracking speed of the algorithm considerably increases and depending on sign of change in dc-link current, it perturbs in right direction without drift. Corresponding theoretical analysis confirms that only in speed increase condition, the change in dc-link current sign is positive. To validate this algorithm, a laboratory prototype of the stand-alone WEGS is developed and implemented in DS1103 digital platform. The performance of the proposed technique is compared with both conventional speed sensor based and speed sensorless algorithm. This algorithm doesn't require any extra sensor to observe wind speed change with a good tracking response and higher efficiency compared to conventional P&O.

16 January 2024 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
PBPradyumna Kumar Behera
Pradyumna Kumar Behera
Monalisa PattnaikMonalisa Pattnaik
Monalisa Pattnaik
Direct current microgrid has emerged as a new trend and a smart solution for seamlessly integrating renewable energy sources (RES) and energy storage systems (ESS) to foster a sustainable energy ecosystem. This paper presents a novel power distribution control scheme (PDCS) designed for a small-scale wind-energy fed low-voltage direct current (LVDC) microgrid. The intermittent nature and stochastic volatility of wind energy as well as the unpredictable variations in load demand necessitate the integration of both high-power and high-energy density storage systems in a microgrid. In this context, an actively configured battery and supercapacitor (SC) based hybrid energy storage system (HESS) is linked to the 48 V LVDC bus. The central idea of hybridization is to mitigate the instantaneous surge current demand and alleviate the charge/discharge stress of the battery during transients enhancing the cycle life of the battery. This makes the integrated wind system more dependable and reliable. The proposed PDCS improves the power-sharing among battery and SC to resolve the demand-generation disparity and maintains state-of-charge ( $SOC$ ) within operational boundaries in addition to faster regulation of DC bus voltage rated at 48 V. The developed autonomous LVDC system with the suggested PDCS is experimentally validated with different case studies. The comparative experimental result analysis substantiates the efficacy of the PDCS along with a seamless transition between various modes. Additionally, the novel scheme addresses the charge/discharge control of SC enabling faster SOC recovery.

16 June 2023 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
PBPradyumna Kumar Behera
Pradyumna Kumar Behera
Monalisa PattnaikMonalisa Pattnaik
Monalisa Pattnaik
The present work proposes a coordinated power management scheme (CPMS) of wind energy-fed self-excited induction generator (SEIG) based low-voltage direct current (LVDC) autonomous microgrid. The battery and supercapacitor (SC) based hybrid energy storage system (HESS) is interfaced with the common 48 V LVDC bus using a parallel-active configuration through two bidirectional converters. The central idea of hybridization is to mitigate the instantaneous surge current demand and alleviate the charge/discharge stress during transients, thus ultimately enhancing the cycle life of the battery. The experimental validation of the autonomous LVDC microgrid equipped with the CPMS is conducted for various operating modes. The dSPACE DS1103 digital controller is used for the real-time implementation of the complete system. The effectiveness of the proposed CPMS is supported by the analysis of comparative experimental results demonstrates its ability to incorporate seamless mode transition. The developed 48 V LVDC microgrid can be a promising solution for powering consumer electronics in homes/office spaces or other small-scale applications.

9 October 2012 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Monalisa PattnaikMonalisa Pattnaik
Monalisa Pattnaik
DKDebaprasad Kastha
Debaprasad Kastha
In this paper, an improved sensorless control algorithm for a variable speed constant frequency doubly fed induction generator is presented. Unlike previously reported methods the proposed algorithm does not require the rotor position or speed information for the stator field orientation of the rotor variables. The slip frequency is estimated by a reactive power-based model reference adaptive observer and is used in the rotor current controllers for back emf compensation. A new on-line estimation method for the magnetizing inductance of the machine is also proposed to enhance the performance of the controller. Small-signal models of the slip frequency and the magnetizing inductance estimators are developed to aid their design. The proposed algorithm is capable of “speed catching on the fly” and performs satisfactorily with balanced, unbalanced, linear, and nonlinear loads (in any combination) particularly, nonlinear unbalanced loads, which has not been reported in the literature so far. Experimental and simulation results are presented to demonstrate an excellent load voltage regulation property of the control algorithm during severe transient operating conditions. Total harmonic distortion and unbalance of the load voltage and stator current even with large nonlinear/unbalanced loads are also found to be much smaller compared to systems reported earlier.


19 December 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Monalisa PattnaikMonalisa Pattnaik
Monalisa Pattnaik
DKDebaprasad Kastha
Debaprasad Kastha
Doubly fed induction generator (DFIG)-based stand-alone variable-speed constant-frequency systems reported so far cannot supply nonlinear unbalanced load current containing cophasor components. This paper presents three topologies of a stand-alone DFIG which can handle this type of load. The harmonic/imbalance component of the load current in each case is supplied by the stator-side converter. In the first option, a Δ/ Y transformer with neutral connection supplies the load. However, the harmonic current circulating in the delta winding still distorts the load phase voltage beyond the acceptable limit. As a solution, the zero-sequence load voltage is actively controlled through the stator-side converter with the load neutral connected to the midpoint of the dc-link capacitor. However, this configuration also fails when the load current contains dc component as in half-wave rectifiers. Finally, a configuration with an additional inverter leg connected to the load neutral is proposed in conjunction with the zero-sequence stator voltage controller. Simulation and experimental results from this last configuration demonstrate its excellent load voltage regulation property while supplying various nonlinear and unbalanced loads. The control algorithm is implemented without any speed/position sensor.