Maksym Pantin

Mr. Maksym Pantin

Computer Science, Institute of Mathematical Machines and Systems Problems, Kyiv, Kyyiv, Misto, Ukraine
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2023 in Algorithms
Verified
Journal Article
Open access
PDF file
Maxim V. SavelievMaxim V. Saveliev
Maxim V. Saveliev
Maksym PantinMaksym Pantin
Maksym Pantin
ISIgor Skiter
Igor Skiter
TSThomas Bligh Scott
Thomas Bligh Scott
Peter MartinPeter Martin
Peter Martin
This work presents the application of a novel evolutional algorithmic approach to determine and reconstruct the specific 3-dimensional source location of gamma-ray emissions within the shelter object, the sarcophagus of reactor Unit 4 of the Chornobyl Nuclear Power Plant. Despite over 30 years having passed since the catastrophic accident, the high radiation levels combined with strict safety and operational restrictions continue to preclude many modern radiation detection and mapping systems from being extensively or successfully deployed within the shelter object. Hence, methods for reconstructing the intense and evolving gamma fields based on the limited inventory of available data are crucially needed. Such data is particularly important in planning the demolition of the unstable structures that comprise the facility, as well as during the prior operations to remove fuel containing materials from inside the sarcophagus and reactor Unit 4. For this approach, a simplified model of gamma emissions within the shelter object is represented by a series of point sources, each regularly spaced on the shelter object’s exterior surface, whereby the calculated activity values of these discrete sources are considered as a population in terms of evolutionary algorithms. To assess the numerical reconstruction, a fitness function is defined, comprising the variation between the known activity values (obtained during the commissioning of the New Safe Confinement at the end of 2019 on the level of the main crane system, located just below the arch above the shelter object) and the calculated values at these known locations for each new population. The final algorithm’s performance was subsequently verified using newly obtained information on the gamma dose-rate on the roof of the shelter object during radiation survey works at the end of 2021. With only 7000 iterations, the algorithm attained an MAPE percentage error of less than 23%, which the authors consider as satisfactory, considering that the relative error of the measurements is ±17%. While a simple initial application is presented in this work, it is demonstrated that evolutional algorithms could be used for radiation mapping with an existing network of radiation sensors, or, as in this instance, based on historic gamma-field data.

1 January 2026 in Mathematical machines and systems
Verified
Journal Article
Closed access
Maksym PantinMaksym Pantin
Maksym Pantin
An approach is proposed for constructing a spatial radiation contamination map of complex in-dustrial facilities in cases where detailed site survey is limited or hazardous due to high dose rates. Under such conditions, available equivalent dose rate measurements are obtained only at individually accessible points, forming an irregular observation network. The problem is treated as an inverse problem of reconstructing the spatial activity distribution from a limited number of dosimetric measurements, allowing for explicit consideration of the physical constraints of the model and the facility geometry. An information system that covers all major stages of do-simetric data processing — from data loading and initial approximation to iterative activity dis-tribution reconstruction and result validation against control points — has been developed. The functional structure is described using IDEF0 (five processing stages with feedback loops). The architecture is implemented as a multi-tier system consisting of a web tier (Nginx, Gunicorn, Django), a computational node (Python, NumPy, Pandas), and a data storage tier (PostgreSQL), interacting via the RabbitMQ message broker. Decoupling the computational core from the web tier allows the system to operate either as a standalone decision support system or as a compu-tational module within other information systems. Validation has been performed on experi-mental data from the Shelter Object of the Chornobyl NPP. After more than 7,000 iterations of the evolutionary algorithm, a mean absolute percentage error of less than 23 % has been achieved at a relative measurement uncertainty of approximately 17 %, corresponding to the accuracy limit imposed by the input measurement error.

1 January 2024 in Nuclear Power and the Environment
Verified
Journal Article
Closed access
Oleksander MykhailovOleksander Mykhailov
Oleksander Mykhailov
Maxim V. SavelievMaxim V. Saveliev
Maxim V. Saveliev
IUInstitute of Mathematical Machines and Systems Problems NAS of Ukraine
Institute of Mathematical Machines and Systems Problems NAS of Ukraine
Maksym PantinMaksym Pantin
Maksym Pantin
After the construction of the Shelter object (SO), also known as Chornobyl Sarcophagus, several research measurement systems were created to understand and monitor the fuel-containing materials behaviour. Within the framework of the SO, transformation into environmentally safe system by the construction of the New Safe Confinement (NSC), and prior to the protective Arch was set into design position, integrated automated monitoring system (IAMS), was created. One of components of the IAMS is the Stationary Radiation Monitoring System (SRMS), designed for monitoring of such parameters of the radiation situation in the SO rooms and the industrial site as gamma equivalent dose rate (GDR) and volumetric activity of α-, β- aerosols in the air. This work is devoted to the analysis of the SRMS data in terms of the GDR measurements results. The analysis of the GDR data in the SO rooms for 34 monitoring point, received during the years 2018–2023, was carried out. It was established that only one type of GDR dynamics is observed in the SO rooms — a constant decrease in the average monthly value against the background of pronounced seasonal fluctuations. The average annual decrease of GDR is estimated as — 2.12±0.57%/year, which is 8% lower than the rate of radioactive decay of 137Cs. Compared to the rate of radioactive decay of 137Cs in rooms that meet the conditions for permanent staff presence, the GDR decrease more slowly than in rooms categorized as periodic and limited stay. The results of SRMS data approximation obtained in the work make it possible to reliably predict the GDR levels in the controlled SO rooms and can be used to plan works and estimate the time when, under conditions of high GRD levels, such works can be performed by personnel in the places where they are carried out.

24 July 2026 in Drones
Verified
Journal Article
Open access
PDF file
Maxim V. SavelievMaxim V. Saveliev
Maxim V. Saveliev
Vladyslav ShtefanVladyslav Shtefan
Vladyslav Shtefan
TSThomas Bligh Scott
Thomas Bligh Scott
VGViktor Grechaninov
Viktor Grechaninov
Oleksander MykhailovOleksander Mykhailov
Oleksander Mykhailov
Maksym PantinMaksym Pantin
Maksym Pantin
On 14 February 2025, the outer cladding of the Chornobyl New Safe Confinement (NSC) was damaged by an explosion caused by a one-way attack unmanned aerial vehicle (UAV), creating a hole of about 15 m in diameter and requiring about 300 penetrations to be made in the cladding during firefighting. This created an urgent need to assess radiation dose rates above damaged areas to support repair planning and worker radiation protection. This study presents a UAV-based survey of the equivalent gamma dose rate distribution above the damaged northern side of the NSC outer cladding. The survey used a bespoke system, integrating a multirotor UAV, an AccuRad Personal Radiation Detector (PRD), onboard data acquisition and transmission modules, and ground-based and server-side analytical components. Measurements were performed under real post-incident field conditions, including restricted flight zones, wind-induced turbulence, proximity to large metallic structures, and electronic warfare interference. The dataset was filtered for Global Positioning System (GPS) reliability, transformed into a metric coordinate system, and processed for spatial interpolation and mapping. The resulting distribution showed a spatially non-uniform radiation field: the main damage zone had relatively low equivalent gamma dose rates, whereas the highest values, up to 1092 μSv/h, were recorded over areas of the NSC closest to the Shelter Object. The study demonstrates UAV-based radiation mapping of a damaged large-scale confinement structure and provides data supporting Chornobyl Nuclear Power Plant repair planning.