Md Tarikul Islam

Mr. Md Tarikul Islam

Graduate research assistant, Department of Electrical electronic and System Engineering, Universiti Kebangsaan Malaysia
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Md. Zulfiker MahmudMd. Zulfiker Mahmud
Md. Zulfiker Mahmud
Md Tarikul IslamMd Tarikul Islam
Md Tarikul Islam
SKS. Kibria
S. Kibria
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
Globally, breast cancer is a major reason for female mortality. Due to the limitations of current clinical imaging, the researchers are encouraged to explore alternative and complementary tools to available techniques to detect the breast tumor in an earlier stage. This article outlines a new, portable, and low-cost microwave imaging (MWI) system using an iterative enhancing technique for breast imaging. A compact side slotted tapered slot antenna is designed for microwave imaging. The radiating fins of tapered slot antenna are modified by etching nine rectangular side slots. The irregular slots on the radiating fins enhance the electrical length as well as produce strong directive radiation due to the suppression of induced surface currents that radiate vertically at the outer edges of the radiating arms with end-fire direction. It has remarkable effects on efficiency and gain. With the addition of slots, the side-lobe levels are reduced, the gain of the main-lobe is increased and corrects the squint effects simultaneously, thus improving the characteristics of the radiation. For experimental validation, a heterogeneous breast phantom was developed that contains dielectric properties identical to real breast tissues with the inclusion of tumors. An alternative PC controlled and microcontroller-based mechanical MWI system is designed and developed to collect the antenna scattering signal. The radiated backscattered signals from the targeted area of the human body are analyzed to reveal the changes in dielectric properties in tissues. The dielectric constants of tumorous cells are higher than that of normal tissues due to their higher water content. The remarkable deviation of the scattered field is processed by using newly proposed Iteratively Corrected Delay and Sum (IC-DAS) algorithm and the reconstruction of the image of the phantom interior is done. The developed UWB (Ultra-Wideband) antenna based MWI has been able to perform the detection of tumorous cells in breast phantom that can pave the way to saving lives.

5 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
Md Tarikul IslamMd Tarikul Islam
Md Tarikul Islam
SKSalehin Kibria
Salehin Kibria
MSMandeep Singh Jit Singh
Mandeep Singh Jit Singh
Microwave breast imaging has been reported as having the most potential to become an alternative or additional tool to the existing X-ray mammography technique for detecting breast tumors. Microwave antenna sensor performance plays a significant role in microwave imaging system applications because the image quality is mostly affected by the microwave antenna sensor array properties like the number of antenna sensors in the array and the size of the antenna sensors. In this paper, a new system for successful early detection of a breast tumor using a balanced slotted antipodal Vivaldi Antenna (BSAVA) sensor is presented. The designed antenna sensor has an overall dimension of 0.401λ × 0.401λ × 0.016λ at the first resonant frequency and operates between 3.01 to 11 GHz under 10 dB. The radiating fins are modified by etching three slots on both fins which increases the operating bandwidth, directionality of radiation pattern, gain and efficiency. The antenna sensor performance of both the frequency domain and time domain scenarios and high-fidelity factor with NFD is also investigated. The antenna sensor can send and receive short electromagnetic pulses in the near field with low loss, little distortion and highly directionality. A realistic homogenous breast phantom is fabricated, and a breast phantom measurement system is developed where a two antennas sensor is placed on the breast model rotated by a mechanical scanner. The tumor response was investigated by analyzing the backscattering signals and successful image construction proves that the proposed microwave antenna sensor can be a suitable candidate for a high-resolution microwave breast imaging system.

5 December 2018 in IEEE Access
Verified
Journal Article
Open access
Md Tarikul IslamMd Tarikul Islam
Md Tarikul Islam
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
SKSalehin Kibria
Salehin Kibria
MIMohammad Tariqul Islam
Mohammad Tariqul Islam

21 November 2019 in Scientific Reports
Verified
Journal Article
Open access
Md Tarikul IslamMd Tarikul Islam
Md Tarikul Islam
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
SKSalehin Kibria
Salehin Kibria
NMNorbahiah Misran
Norbahiah Misran
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
In this paper, the design consideration is investigated for a cylindrical system with low-cost and low-loss dielectric materials for the detection of breast tumor using iteratively corrected delay multiply and sum (IC- DMAS) algorithm. Anomaly in breast tissue is one of the most crucial health issues for women all over the world today. Emergency medical imaging diagnosis can be harmlessly managed by microwave-based analysis technology. Microwave Imaging (MI) has been proved to be a reliable health monitoring approach that can play a fundamental role in diagnosing anomaly in breast tissue. An array of 16 high gain microstrip antennas loaded by Index Near-Zero (INZ) metasurfaces (MS), having the impedance bandwidth of 8.5 GHz (2.70–11.20 GHz) are used as transceivers for the system. The MS is used to increase the electrical length of the signal that results in the gain enhancements. The antennas are mounted in a cylindrical arrangement on a mechanical rotating table along with a phantom mounting podium. A non-reflective positive control switching matrix is used for transmitting and receiving microwave signals. A set of lab-made realistic heterogeneous breast phantoms containing skin, fat, glandular, and tumor tissue dielectric properties in individual layers are used to verify the performance of the proposed technique. The control of the mechanical unit, data collection, and post-processing is conducted via MATLAB. The system can detect multiple tumor objects. The imaging results and numerical Signal to Mean Ratio (SMR) values of the experiment validate the system efficiency and performance that can be a viable solution for tumor detections.

21 March 2019 in IEEE Access
Verified
Journal Article
Open access
SKSalehin Kibria
Salehin Kibria
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
Md Tarikul IslamMd Tarikul Islam
Md Tarikul Islam
Md. Zulfiker MahmudMd. Zulfiker Mahmud
Md. Zulfiker Mahmud
NMNORBAHIAH BINTI MISRAN
NORBAHIAH BINTI MISRAN
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
In this paper, a system for microwave breast tumor detection is presented using iteratively corrected coherence factor delay and sum (CF-DAS) algorithm. CF-DAS is data independent, which makes it stable in a noisy environment. However, data adaptive techniques have made significant progress by enhancing the image quality in microwave tomography. Thus, a novel data adaptive iterative variant of CF-DAS is proposed in this paper to produce stable and accurate images. The microwave imaging (MI) system contains a rotatable array of nine modified antipodal Vivaldi antennas in a circular arrangement, an array-mounting stand based on the stepper motor, the flexible phantom mounting podium, a control system for RF switching of the transceivers, and signal processing unit based on personal computer involved in the reconstruction of the image. The impedance bandwidth of the modified antenna is recorded from 2.5 to 11 GHz with stable directional radiation pattern. For performing the transmission and reception of the microwave signals, an SP8T nine port RF switch is used ranging from 2.5 to 8.0 GHz, and the switching is controlled by MATLAB software. Several low-cost lab-based homogenous and heterogeneous phantoms containing the dielectric property of human breast and tumor tissue are prepared to test the system efficiency. Since typical data independent radar-based techniques are ill-equipped for multiple reflection scenarios, an iteratively corrected variant of CF-DAS algorithm is used for processing the recorded backscattered signals to reconstruct the image of the breast phantom and to identify the existence and locate the area of the multiple breast tumors. The proposed method achieves more than 10-dB improvement over conventional CF-DAS in terms of signal to mean ratio for four different phantoms measured in this study.

2 November 2020 in Materials
Verified
Journal Article
Open access
PDF file
AHAmran Hossain
Amran Hossain
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Md Tarikul IslamMd Tarikul Islam
Md Tarikul Islam
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
HRHatem Rmili
Hatem Rmili
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
In this paper, a compact planar ultrawideband (UWB) antenna and an antenna array setup for microwave breast imaging are presented. The proposed antenna is constructed with a slotted semicircular-shaped patch and partial trapezoidal ground. It is compact in dimension: 0.30λ × 0.31λ × 0.011λ, where λ is the wavelength of the lowest operating frequency. For design purposes, several parameters are assumed and optimized to achieve better performance. The prototype is applied in the breast imaging scheme over the UWB frequency range 3.10–10.60 GHz. However, the antenna achieves an operating bandwidth of 8.70 GHz (2.30–11.00 GHz) for the reflection coefficient under–10 dB with decent impedance matching, 5.80 dBi of maximum gain with steady radiation pattern. The antenna provides a fidelity factor (FF) of 82% and 81% for face-to-face and side-by-side setups, respectively, which specifies the directionality and minor variation of the received pulses. The antenna is fabricated and measured to evaluate the antenna characteristics. A 16-antenna array-based configuration is considered to measure the backscattering signal of the breast phantom where one antenna acts as transmitter, and 15 of them receive the scattered signals. The data is taken in both the configuration of the phantom with and without the tumor inside. Later, the Iteratively Corrected Delay and Sum (IC–DAS) image reconstructed algorithm was used to identify the tumor in the breast phantom. Finally, the reconstructed images from the analysis and processing of the backscattering signal by the algorithm are illustrated to verify the imaging performance.