Marco Vinicio Chavez Baez

Prof. Marco Vinicio Chavez Baez

Postgrado de Ingeniería Electrónica, TecNM-Instituto Tecnológico de Morelia, Morelia, Michoacán de Ocampo, Mexico
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2025 in Computers
Verified
Journal Article
Open access
PDF file
Jonatan Ali Medina-MolinaJonatan Ali Medina-Molina
Jonatan Ali Medina-Molina
EAEnrique Reyes Archundia
Enrique Reyes Archundia
JGJose Antonio Gutierrez Gnecchi
Jose Antonio Gutierrez Gnecchi
JRJavier Rodriguez-Herrejon
Javier Rodriguez-Herrejon
Marco Vinicio Chavez BaezMarco Vinicio Chavez Baez
Marco Vinicio Chavez Baez
N.F. Guerrero-RodríguezN.F. Guerrero-Rodríguez
N.F. Guerrero-Rodríguez
The introduction of renewable energy sources, distributed energy systems, and power electronics equipment has led to the emergence of the Smart Grid. However, these developments have also caused the worsening of power quality. Selecting the correct sampling frequency and feature extraction techniques are essential for appropriately analyzing power quality disturbances. This work compares the performance of an algorithm based on a Support Vector Machine and Discrete Wavelet Transform for the classification of power quality disturbances using eight sampling rates and five different mother wavelets. The algorithm was tested in noisy and noiseless scenarios to show the methodology. The results indicate that a success rate of 99.9% is obtained for the noiseless signals using a sampling rate of 9.6 kHz and 95.2% for signals with a signal-to-noise ratio of 30 dB with a sampling rate of 30 kHz.

1 February 2025 in Applied Soft Computing
Verified
Journal Article
Closed access
EREilen García Rodríguez
Eilen García Rodríguez
EAEnrique Reyes Archundia
Enrique Reyes Archundia
JGJose Antonio Gutierrez Gnecchi
Jose Antonio Gutierrez Gnecchi
APArturo Méndez Patiño
Arturo Méndez Patiño
Marco Vinicio Chavez BaezMarco Vinicio Chavez Baez
Marco Vinicio Chavez Baez
N.F. Guerrero-RodríguezN.F. Guerrero-Rodríguez
N.F. Guerrero-Rodríguez

19 April 2024 in IEEE Access
Verified
Journal Article
Open access
JRJavier Rodriguez-Herrejon
Javier Rodriguez-Herrejon
EAEnrique Reyes Archundia
Enrique Reyes Archundia
JGJose Antonio Gutierrez Gnecchi
Jose Antonio Gutierrez Gnecchi
Marco Vinicio Chavez BaezMarco Vinicio Chavez Baez
Marco Vinicio Chavez Baez
AMArturo Méndez-Pátiño
Arturo Méndez-Pátiño
This paper presents a Hardware in the Loop simulation for the detection, classification, and location of faults in transmission lines with Unified Power Flow Controller compensation. Hardware devices are proposed to demonstrate that the traveling wave concept for fault location in a Hardware in the Loop simulation is possible and replicable under laboratory conditions. The devices used are a MacBook Air M1 2020 computer to get the SIMULINK values from the local end of the transmission line, two FeelElec FY8300S generators to import the simulation data, then they send the signals to an AT91SAM3X8E microcontroller to perform the fault detection, when the cycle of the signals where the fault is obtained, they are sent to the UDOO BOLT v8 device to get the classification and location of the fault. The results obtained indicate that the error for estimating the fault distance is less than 0.71% of the total line length, and the classification efficiency is 94.18%.

1 September 2013
Verified
Conference Paper
Closed access
Marco Vinicio Chavez BaezMarco Vinicio Chavez Baez
Marco Vinicio Chavez Baez
OAOlimpo Anaya-Lara
Olimpo Anaya-Lara
KLKwok L. Lo
Kwok L. Lo
JMJim McDonald
Jim McDonald
This paper presents a review of harmonics in offshore wind farm systems. The aim is to gather information of mathematical models for harmonic analysis in wind farms and algorithms to configure offshore network interconnections. A thorough literature review is presented that may help to develop a solution in MatLab or LabView for harmonic analysis in offshore wind farms with multi-technology components.

1 September 2013
Verified
Conference Paper
Closed access
Marco Vinicio Chavez BaezMarco Vinicio Chavez Baez
Marco Vinicio Chavez Baez
OAOlimpo Anaya-Lara
Olimpo Anaya-Lara
KLKwok L. Lo
Kwok L. Lo
JMJim McDonald
Jim McDonald
This paper presents an algorithm, based on the simplex method, to reconfigure distribution systems minimizing harmonics and power losses. The algorithm is implemented in LabView and calculates the power flow and the harmonics flow, then uses the simplex method to obtain the maximum current flow, in a second stage the data is saved for each configuration, and finally with all the data, the algorithm suggests the best configuration with less total harmonic distortion and less power losses.

28 October 2025 in Clean Energy
Verified
Journal Article
Open access
JMJosé David Martínez-Soto
José David Martínez-Soto
IMIsmael Molina-Moreno
Ismael Molina-Moreno
Marco Vinicio Chavez BaezMarco Vinicio Chavez Baez
Marco Vinicio Chavez Baez
MGMaría del Carmen García-Ramírez
María del Carmen García-Ramírez
JCJavier Correa-Gómez
Javier Correa-Gómez
In many urban areas of Morelia, Michoacán, the water supply is intermittent, compelling residents to store water in cisterns and pump it to rooftop tanks using conventional electric systems. This study proposes the design and experimental validation of a domestic solar photovoltaic water pumping system as a sustainable and cost-effective solution for regions with irregular water supply. A sizing methodology is presented, which accounts for the required water volume, flow rate based on solar hours, barometric head, and losses due to friction and fittings. To validate the proposed system, an experimental case study was conducted using a 330 W PV panel, a 300 W buck converter, and a 48 W pump, achieving a flow rate of 6.9 L/min and a total dynamic head of 12.57 m. The results show that under real operating conditions, the system demonstrated an efficiency of 29.9% and a service capacity of 4.14 individuals per hour of effective sunlight or 1208.8 m3 per year considering 8 hours of effective sunlight. In addition, the experimental results were validated using the PVSyst simulator, which indicated an annual pumped water of 1204 m3 per year, which closely matches with the experimental results. The results confirm the technical feasibility of the proposed alternative to improve water access in vulnerable urban areas with irregular supply.