Maria Victoria Lopez Molla

Dr. Maria Victoria Lopez Molla

European University of Valencia, Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
KBK Bouazza-Juanes
K Bouazza-Juanes
AMA Martinez-Gonzalez
A Martinez-Gonzalez
GPG Peiro
G Peiro
JRJj Rodenas
Jj Rodenas
MMMaria Victoria Lopez Molla
Maria Victoria Lopez Molla
There exists a relation between the presence and location of the micro-gap and the loss of peri implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled. The first one, of diameter 4.1 mm, was used in the reference model to represent a conventional implant. The second one, of diameter 3.2 mm, was used to represent the implant with platform switching. Both models were subjected to axial and oblique masticatory loads. The analyses showed that, although no relevant differences can be found for the trabecular bone, the use of platform switching reduces the maximum stress level in the cortical bone by almost 36% with axial loads and by 40% with oblique loads. The full 3D Finite Element model, that can be used to investigate the influence of other parameters (implant diameter, connexion type, …) on the biomechanical behaviour of the implant, showed that this stress reduction can be a biomechanical reasons to explain why the platform switching seems to reduce or eliminate crestal bone resorption after the prosthetic restoration. Dental implant, platform switching, finite element method.

MMMilagros Adobes Martín
Milagros Adobes Martín
NANATIVIDAD ALCÓN
NATIVIDAD ALCÓN
MMMaria Victoria Lopez Molla
Maria Victoria Lopez Molla
JGJAVIER Gamez-Paya
JAVIER Gamez-Paya
ELEstibaliz López-Fernández
Estibaliz López-Fernández
Translucency is one of the most important parameters to be considered by digital systems when predicting the matching appearance and hence the quality of prosthodontic restoration work. Our objective has been to improve the effectiveness of the algorithmic decision systems employed by these devices by (a) determining whether Kubelka-Munk theory can be used as an algorithm for predicting restoration suitability, and (b) evaluating the correlation between the visual evaluation of prosthodontic materials and the predicted translucency based on the use of the ΔE*, OP, CR, and K/S algorithms. In this regard, three zirconia systems and one lithium disilicate have been spectrophotometrically and visually characterized. Based on the results of this study, it has been proven that zirconia systems and lithium disilicate systems exhibit different optical behaviors. The psychophysical experience suggests that none of the existing mathematical methods can adequately estimate translucency, spectrophotometric, and colorimetric techniques, and that which is perceived by an experienced observer. However, translucency evaluation through the K/S algorithmic decision system should not be disregarded. New methods to measure translucency should be developed to improve digital systems for prosthodontic applications.

1 July 2015 in The International Journal of Prosthodontics
Verified
Journal Article
Closed access
MMMaria Victoria Lopez Molla
Maria Victoria Lopez Molla
AMAmparo Martínez-González
Amparo Martínez-González
Vicente Amigo BorrasVicente Amigo Borras
Vicente Amigo Borras
JMJosé Mañes-Ferrer
José Mañes-Ferrer
Maria Victoria L?pez-Moll?, DDS, PhD/Amparo Mart?nez-Gonz?lez, MD, DDS, PhD/ Vicente Amig?-Borr?s, PhD/Jos? F?lix Ma?es-Ferrer, MD, DDS, PhD: This study analyzed the shear strength and fracture characteristics of the interface between zirconia samples and their veneering ceramic compared with a metal-ceramic and a lithium disilicate glass-ceramic control group together with an assessment of the possible relationship between the fracture characteristics and the recorded shear strength. The greatest shear strengths corresponded to the lithium disilicate glass-ceramic control group followed by the metal-ceramic control group, with lesser strengths in the zirconia groups. Since the fractographic study showed cohesive-type failure to predominate in the zirconia samples, it is concluded that improvements are needed in the veneering ceramic and liner used in zirconia restorations.