Dávid Nagy

Mr. Dávid Nagy

Student -PhD

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DNDávid Nagy
Dávid Nagy
JFJozsef Felfoldi
Jozsef Felfoldi
ABAndrea Taczmanne Bruckner
Andrea Taczmanne Bruckner
CMCsilla Mohacsi-Farkas
Csilla Mohacsi-Farkas
ZBZsanett Bodor
Zsanett Bodor
VZViktoria Zsom-Muha
Viktoria Zsom-Muha
In this study, liquid egg, albumen, and egg yolk were artificially inoculated with E. coli. Ultrasound equipment (20/40 kHz, 180/300 W; 30/45/60 min) with a circulation cooling system was used to lower the colony forming units (CFU) of E. coli samples. Frequency, absorbed power, energy dose, and duration of sonication showed a significant impact on E. coli with 0.5 log CFU/mL in albumen, 0.7 log CFU/mL in yolk and 0.5 log CFU/mL decrease at 40 kHz and 6.9 W absorbed power level. Significant linear correlation (p < 0.001) was observed between the energy dose of sonication and the decrease of E. coli. The results showed that sonication can be a useful tool as a supplementary method to reduce the number of microorganism in egg products. With near-infrared (NIR) spectra analysis we were able to detect the structural changes of the egg samples, due to ultrasonic treatment. Principal component analysis (PCA) showed that sonication can alter C–H, C–N, –OH and N–H bonds in egg. The aquagrams showed that sonication can alter the properties of H2O structure in egg products. The observed data showed that the absorbance of free water (1412 nm), water molecules with one (1440 nm), two (1462 nm), three (1472 nm) and four (1488 nm) hydrogen bonds, water solvation shell (1452 nm) and strongly bonded water (1512 nm) of the egg samples have been changed during ultrasonic treatment.

16 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DNDávid Nagy
Dávid Nagy
László BaranyaiLászló Baranyai
László Baranyai
LNLien Le Phuong Nguyen
Lien Le Phuong Nguyen
ABAndrea Taczman Brückner
Andrea Taczman Brückner
ZTZsom Tamás
Zsom Tamás
ZVZsom-Muha Viktória
Zsom-Muha Viktória
In this study, sonication with mild heat treatment was used to reduce the E. coli count in inoculated liquid whole egg, egg yolk and albumen. Ultrasonic equipment (20/40 kHz, 180/300 W) has been used for 30/60 min with a 55 °C water bath. The combination of sonication and low-heat treatment was able to reduce the concentration of E. coli from 5-log CFU × mL−1 below 10 CFU × mL−1 at 300 W, 40 kHz and 60 min of sonication in liquid egg products. The 60 min treatment was able to reduce the E. coli concentration below 10 CFU × mL−1 in the case of egg yolk regardless of the applied frequency, absorbed power or applied energy dose. The 30 min treatment of sonication and heating was able to reduce significantly the number of E. coli in the egg products, as well. Our results showed that sonication with mild heat treatment can be a useful technique to decrease the number of microorganisms in liquid egg products to a very low level. Near-infrared spectroscopy was used to investigate structural changes in the samples, induced by the combined treatment. Principal component analysis showed that this method can alter the C-H, C-N, -OH and -NH bonds in these egg products.

13 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DNDávid Nagy
Dávid Nagy
ZTZsom Tamás
Zsom Tamás
ABAndrea Taczman Brückner
Andrea Taczman Brückner
TSTamás Somogyi
Tamás Somogyi
ZVZsom-Muha Viktória
Zsom-Muha Viktória
JFJozsef Felfoldi
Jozsef Felfoldi
Eggs are a valuable source of nutrients, but they represent a food safety risk due to the presence of microbes. In this work, three types of egg liquids (albumen, yolk and whole egg) previously contaminated with E. coli were treated with ultrasound (US) and a combination of ultrasound and low (55 °C) temperature (US+H). The US treatment parameters were 20 and 40 kHz and 180 and 300 W power and a 30, 45 or 60 min treatment time. The ultrasonic treatment alone resulted in a reduction in the microbial count of less than 1 log CFU, while the US+H treatment resulted in a reduction in CFU counts to below detectable levels in all three egg liquids. Heat treatment and ultrasound treatment had a synergistic effect on E. coli reduction. For all measurements, except for the whole egg samples treated with US, the 20 kHz treated samples showed a significantly (>90% probability level) lower bactericidal effect than the 40 kHz treated samples. PCA and aquaphotometric analysis of NIR spectra showed significant differences between the heat-treated groups’ (H and US+H) and the non-heat-treated groups’ (US and control) NIR spectra. LDA results show that heat-treated groups are distinguishable from non-heat-treated groups (for albumen 91% and for egg yolk and whole egg 100%).

29 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
IKIstván Kertész
István Kertész
DNDávid Nagy
Dávid Nagy
László BaranyaiLászló Baranyai
László Baranyai
KPKlára Pásztor-Huszár
Klára Pásztor-Huszár
KVKinga Varsányi
Kinga Varsányi
JFJozsef Felfoldi
Jozsef Felfoldi
Ultrasonic testing is an emerging non-destructive testing technology with high repeatability and precision. Milk is a very complex liquid and the change of its viscosity is a highly relevant property throughout conversion into other dairy products. In the following paper, we propose a novel method for the monitoring of viscosity during enzymatic milk clotting by ultrasonic spectroscopy. An ultrasonic transducer–receiver couple with a 250 kHz nominal frequency was submerged in the samples and an enveloped sweep (“chirp”) signal was applied in a through-transmission mode. Simultaneously, the change in viscosity was measured with a rotational viscometer at a constant shearing speed. The data were analyzed with an algorithm developed by the authors for spectral ultrasonic testing. Estimations yielded a high adjusted R2 (0.963–0.998) and low cross-validated estimation error (RPD: 4.38–14.22), suggesting that the method is suitable for industrial use given the right instrumentation.