11 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
BJBub-Gyu Jeon
Bub-Gyu Jeon
SCSung-Jin Chang
Sung-Jin Chang
SKS W Kim
S W Kim
DPDong-Uk Park
Dong-Uk Park
NCNakhyun Chun
Nakhyun Chun
Among national infrastructure facilities, electric power facilities are very important sites that must maintain their functions properly even during a natural disaster or during social crises. Therefore, seismic design is required when necessary for major electric power facilities that have a significant impact when damaged in the event of an earthquake. In electric power facilities, bushings are generally installed in devices or structures. Therefore, ground acceleration can be amplified through devices, such as transformers, or sub-structures. Among various electric power facilities, cable terminations are representative cantilever-type substation facilities consisting of a bushing, a sub-structure, and support insulators. The bushings of cable terminations are generally made of porcelain or fiber-reinforced plastic (FRP) materials, and they may have different dynamic characteristics. This study attempted to estimate the acceleration amplification ratio in the main positions of cable terminations considering the materials of bushings. For two cable terminations with different specifications and bushing materials, three-axis shake table tests were conducted in accordance with IEEE 693, which includes a seismic performance evaluation method for a power substation facility. The acceleration amplification ratios at the top of the bushing, mass center, and top of the support structure were estimated using the acceleration responses of each cable termination. They were then compared with the acceleration amplification factors presented in design standards. Consequently, the acceleration amplification ratio of cable termination with an FRP bushing was lower than that of the cable termination with a porcelain bushing.

31 October 2024 in Journal of the Korean Society of Hazard Mitigation
Verified
Journal Article
Open access
PDF file
NCNakhyun Chun
Nakhyun Chun
IYIlhwan You
Ilhwan You
JKJi-Su Kim
Ji-Su Kim
SLSeungjung Lee
Seungjung Lee
KHKyeong-Min Hwang
Kyeong-Min Hwang
JKJung Kim
Jung Kim
In this study, the structural performance of electric power tunnels was evaluated based on the type and degree of damage. For experimental performance evaluation, a power structure test specimen was designed with a state safety performance of grade D corresponding to a concrete damage area ratio of 44% and structural safety performance of grade D with a reduced cross-section of 25% of the main reinforcement of the upper slab. The electric power structures with grade D state safety performance and structural safety performance exhibited 63% load-bearing capacity compared to those without damage. Cracks occurred on the outside of the structure under the experimental conditions simulating the overburden load, implying the possibility of corrosion of the outer reinforcing bars of the real structure. Finite element analysis showed that reducing the area of the outer main rebar of the upper slab caused more significant reduction in the load-bearing capacity than that of the inner main rebar.

31 December 2024 in Journal of the Korean Society of Hazard Mitigation
Verified
Journal Article
Open access
PDF file
NCNakhyun Chun
Nakhyun Chun
HCHyunki Choi
Hyunki Choi
JCJoohong Chung
Joohong Chung
KHKyeongmin Hwang
Kyeongmin Hwang
HJHyung-Suk Jung
Hyung-Suk Jung
Recently, the service lives of electric power utility tunnels have been increasing rapidly; however, inspection and maintenance tasks are difficult, and the economic loss owing to the end of tunnels’ lifespans is substantial. Moreover, electric power utility tunnels are exposed to high carbon dioxide. Because their interiors are sealed environments, the tunnels are significantly affected by carbon dioxide. Carbon dioxide can cause concrete carbonation, which can lead to a decline in the performance of electric power utility tunnels. In this study, the carbonation characteristics of concrete were analyzed, and the effect of carbonation on the mechanical performance was evaluated.

31 December 2024 in Journal of the Korean Society of Hazard Mitigation
Verified
Journal Article
Open access
PDF file
NCNakhyun Chun
Nakhyun Chun
HCHyunki Choi
Hyunki Choi
JCJoohong Chung
Joohong Chung
KHKyeongmin Hwang
Kyeongmin Hwang
HJHyung-Suk Jung
Hyung-Suk Jung
Recently, the service life of electric power utility tunnels has been rapidly increasing; however, inspection and maintenance are difficult because of the characteristics of electric power utility tunnels. In addition, there are no detailed guidelines for electric power utility tunnels regarding the safety and maintenance of existing facilities. Therefore, it is necessary to establish a comprehensive performance evaluation system that reflects the characteristics of electric power utility tunnels. In this study, we determine and evaluate the factors influencing durability for the development of a comprehensive performance evaluation system for electric power utility tunnels via a field investigation.

6 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NCNakhyun Chun
Nakhyun Chun
SKS W Kim
S W Kim
SCSung-Jin Chang
Sung-Jin Chang
UKU-Jin Kwon
U-Jin Kwon
BJBub-Gyu Jeon
Bub-Gyu Jeon
SSSu-Won Son
Su-Won Son
Transformers are critical components in power systems, and their functionality must be maintained during seismic events. This study conducted multi-directional shaking table tests on a full-scale 154 kV transformer to investigate the seismic response and failure mechanisms of radiator and conservator connections. Measurements of relative displacement, acceleration, and test response spectra (TRS) indicated stable responses of 0.5–1.2 g for the transformer body, whereas the bushings and radiators exhibited amplified accelerations of up to 4 g and 2 g, respectively, along with relative displacements exceeding 20 mm. Under the 500-year return period input motion, leakage was observed at the lower radiator elbow, which is attributed to the combined effects of concentrated relative displacement, acceleration amplification, frequency-dependent energy concentration, and local structural discontinuities. The observed damage patterns were consistent with leakage incidents reported during the 2024 Noto earthquake in Japan. Based on the experimental findings, this study discusses seismic performance enhancement measures for radiator connections and provides experimental evidence to support the seismic safety evaluation of transformers with similar configurations.