To verify the influence of axial length (AL) variations after cataract surgery in IOL power calculation. Patients underwent ophthalmic evaluation before surgery, including optical biometry with IOLMaster 500. Same exams were repeated 2 months after surgery: AL of operated eye was evaluated using two modes (pseudophakic/aphakic options). Mean Keratometry and AL changes were analyzed. Furthermore, refractive prediction error (PE) was back-calculated with Barrett Universal-II, Hoffer-Q, Holladay-1 and SRK/T formulas. To eliminate any systematic error, the mean error (ME) was zeroed-out for each formula. MEs and median absolute errors (MedAEs) of PEs were analyzed. Two-hundred-one operated eyes of 201 patients and 201 opposite eyes were evaluated. In operated eyes, mean AL difference was − 0.11 ± 0.07 mm (p < 0.001) with pseudophakic option and 0.00 ± 0.07 mm (p = 0.922) with aphakic option. There were not-statistically significant differences between MedAE of PEs calculated after zeroing-out the ME with different ALs (p > 0.05). Instead, only MEs of PEs obtained with postoperative ALs-pseudophakic option were not-statistically different from zero (p > 0.05). AL measurement change after cataract surgery is probably due to a systematic error in optical biometer in case of phakic eyes. A correction factor applied to preoperative AL could eliminate any systematic error in IOL power calculation without modifying the lens constant.
This retrospective comparative study proposes a multi-formula approach by comparing no-history IOL power calculation methods after myopic laser-refractive-surgery (LRS). One-hundred-thirty-two eyes of 132 patients who had myopic-LRS and cataract surgery were examined. ALMA, Barrett True-K (TK), Ferrara, Jin, Kim, Latkany and Shammas methods were evaluated in order to back-calculate refractive prediction error (PE). To eliminate any systematic error, constant optimization through zeroing-out the mean error (ME) was performed for each formula. Median absolute error (MedAE) and percentage of eyes within ±0.50 and ±1.00 diopters (D) of PE were analyzed. PEs were plotted with corresponding mean keratometry (K), axial length (AL), and AL/K ratio; then, different ranges were evaluated. With optimized constants through zeroing-out ME (90 eyes), ALMA was better when K ≤ 38.00 D-AL > 28.00 mm and when 38.00 D < K ≤ 40.00 D-26.50 mm < AL ≤ 29.50 mm; Barrett-TK was better when K ≤ 38.00 D-AL ≤ 26.50 mm and when K > 40.00 D-AL ≤ 28.00 mm or AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges. (p < 0.05) Without modified constants (132 eyes), ALMA was better when K > 38.00 D-AL ≤ 29.50 mm and when 36.00 < K ≤ 38.00 D-AL ≤ 26.50 mm; Barrett-TK was better when K ≤ 36.00 D and when K ≤ 38.00 D with AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges (p < 0.05). A multi-formula approach, according to different ranges of K and AL, could improve refractive outcomes in post-myopic-LRS eyes.
This observational study compared optic coherence tomography (OCT) and B-scan in the detection of optic disc drusen. In total, 86 eyes of 50 patients with optic disc drusen (ODD) (36 bilateral) with a mean age of 34.68 ± 23.81 years, and 54 eyes of 27 patients with papilledema, with a mean age of 35.42 years ± 17.47, were examined. Patients with ODD, diagnosed with ultrasound, underwent spectral-domain OCT evaluation. With US, 28 ODD cases were classified as large (4 buried and 24 superficial), 58 were classified as point-like (6 buried, 49 superficial and 3 mixed). Then, all patients underwent OCT. OCT was able to detect the presence of ODD and/or peripapillary hyperreflective ovoid mass structure (PHOMS) in 69 eyes (p < 0.001). In particular, 7 eyes (8.14%) showed the presence of ODD alone, 25 eyes (29.07%) showed only PHOMS and 37 eyes (43.02%) showed ODD and PHOMS. In 17 eyes (19.77%) no ODD or PHOMS were detected. In the papilledema group, no ODD were observed with both US and OCT. OCT showed the presence of drusen or similar lesions in only 80.23% of the cases highlighted by the US scan, so it does not allow for certain ODD diagnoses, especially in the case of buried ODD.
To test a new method to calculate the Intraocular Lens (IOL) power, that combines R Factor and ALxK methods, that we called Advance Lens Measurement Approach (ALMA). Retrospective, Comparative, Observational study. Department of Medicine and Surgery, University of Salerno, Italy. Ninety one eyes of 91 patients previously treated with Photorefractive Keratectomy (PRK) or Laser-Assisted in Situ Keratomileusis (LASIK) that underwent phacoemulsification and IOL implantation in the capsular bag were analyzed. For 68 eyes it was possible to zero out the Mean Errors (ME) for each formula and for selected IOL models, in order to eliminate the bias of the lens factor (A-Costant). Main outcome, measured in this study, was the median absolute error (MedAE) of the refraction prediction. In the sample with ME zeroed (68 eyes) both R Factor and ALxK methods resulted in MedAE of 0.67 D. For R Factor 33 eyes (48.53%) reported a refractive error <0.5D, and 53 eyes (77.94%) reported a refractive error <1D, For ALxK method, 32 eyes (47.06%) reported a refractive error <0.5 D, and 53 eyes (77.94%) reported a refractive error <1 D. ALMA method, reported a MedAE of 0.55 D, and an higher number of patients with a refractive error <0.5 D (35 eyes, 51.47%), and with a refractive error <1 D (54 eyes, 79.41%). Based on the results obtained from this study, ALMA method can improve R Factor and ALxK methods. This improvement is confirmed both by zeroing the mean error and without zeroing it.
Comparing IOL power calculation formulas in long eyes (AL≥26.00 mm) to find the best axial length (AL) adjustment/IOL power calculation formula combination. Retrospective, comparative, case-series. Patients with long eyes that underwent cataract surgery. five-hundred-fifty-four eyes of 554 patients were examined before and after standard phacoemulsification without complications. Eyes were subdivided in 3 groups according to AL: 26.00≤AL<28.00 mm, 28.00≤AL<30.00 mm, AL≥30.00 mm. Eight formulas that do not require anterior chamber depth (ACD) were evaluated: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Ladas Super Formula (LSF), Hoffer Q, Holladay 1, SRKT, T2 and T2.2. The lens constant of ULIB database and IOLCon database were used. Each formula was analyzed by using uncorrected AL (ALu) and following AL adjustments: Wang-Koch 1 (wk1), wk2, wk polinomial (wk-pol), estimated Cooke modified axial length (CMALe) and ALc correcting factor. Mean absolute error (MAE), median absolute error (MedAE) and percentage of eyes within ±0.50 and ± 1.00 diopters (D) of prediction error. T2-ALu gave best outcome when 26.00 mm ≤ AL<28.00 mm. LSF-ALu, BUII-ALu, EVO 2.0-ALu, Holladay 1-wk-pol and T2.2-CMALe represented valid alternatives. EVO 2.0-ALc gave best outcomes when 28.00 mm ≤ AL<30.00 mm. Other thick-lens or hybrid artificial-intelligence-vergence based formulas (BUII-ALu, LSF-CMALe) and Holladay 1-wk2 demonstrated greater reliability compared to thin lens-based formulas. EVO 2.0-CMALe gave best outcomes when AL≥30.00 mm. Holladay 1-wk-pol e T2.2-wk1 represented valid alternatives (all p < 0.050). LSF could fail in 50 % of cases without ACD when AL≥30.00 mm. Choosing the best AL adjustment/IOL power calculation formula combination for each AL subrange, can improve refractive outcomes in patients with long eyes that undergo cataract surgery.
Background: To evaluate the interocular optic nerve diameter (ONDs) asymmetry in patients with idiopathic intracranial hypertension (IIH) utilizing the A-scan ultrasound technique. Methods: Thirty-seven patients diagnosed with IIH were recruited from outpatients referred to the University Eye Unit between June 2014 and December 2021. Patients with optic disc pseudoedema or edema caused by other conditions were excluded. All patients with negative neuroimaging for intracranial space-occupying masses underwent standardized A-scan measurement of the OND in the primary gaze and lateral position (30 degrees test). Results: Mean, median, standard deviation, the minimum and maximum value of the two eyes at 0 degrees and the difference between the left and right thicker and thinner ONDs were measured. The two-tailed paired student t-test between the two eyes was performed using SPSS software. A statistically significant difference (p-value <0.001) between the two eyes, without a side prevalence, was found. Conclusions: Due to the differences between the ONDs of both eyes, we propose to use the mean of the ONDs between the left and right eyes at 0 degrees with the standardized A-scan diagnostic technique for a better follow-up of patients with IIH.