Nasser Mohamed-Noriega

Prof. Dr. Nasser Mohamed-Noriega

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
SLShaohua Liu
Shaohua Liu
PGPavlo Gordiichuk
Pavlo Gordiichuk
Zhong-Shuai WuZhong-Shuai Wu
Zhong-Shuai Wu
ZLZhaoyang Liu
Zhaoyang Liu
WWWei Wei
Wei Wei
XFXinliang Feng
Xinliang Feng
The ability to pattern functional moieties with well-defined architectures is highly important in material science, nanotechnology and bioengineering. Although two-dimensional surfaces can serve as attractive platforms, direct patterning them in solution with regular arrays remains a major challenge. Here we develop a versatile route to pattern two-dimensional free-standing surfaces in a controlled manner assisted by monomicelle close-packing assembly of block copolymers, which is unambiguously revealed by direct visual observation. This strategy allows for bottom-up patterning of polypyrrole and polyaniline with adjustable mesopores on various functional free-standing surfaces, including two-dimensional graphene, molybdenum sulfide, titania nanosheets and even on one-dimensional carbon nanotubes. As exemplified by graphene oxide-based mesoporous polypyrrole nanosheets, the unique sandwich structure with adjustable pore sizes (5–20 nm) and thickness (35–45 nm) as well as enlarged specific surface area (85 m2 g−1) provides excellent specific capacitance and rate performance for supercapacitors. Therefore, this approach will shed light on developing solution-based soft patterning of given interfaces towards bespoke functions.

30 June 2014 in ACS Nano
Verified
Journal Article
Closed access
GHGuang-Ping Hao
Guang-Ping Hao
FHFelix Hippauf
Felix Hippauf
Martin OschatzMartin Oschatz
Martin Oschatz
FWFlorian M. Wisser
Florian M. Wisser
ALAnnika Leifert
Annika Leifert
SKStefan Kaskel
Stefan Kaskel

1 December 2013 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
GMGiovanni Mondin
Giovanni Mondin
FWFlorian M. Wisser
Florian M. Wisser
ALAnnika Leifert
Annika Leifert
Nasser Mohamed-NoriegaNasser Mohamed-Noriega
Nasser Mohamed-Noriega
JGJulia Grothe
Julia Grothe
SKStefan Kaskel
Stefan Kaskel

1 December 2013 in Electrochimica Acta
Verified
Journal Article
Closed access
GMGiovanni Mondin
Giovanni Mondin
MLMartin Lohe
Martin Lohe
FWFlorian M. Wisser
Florian M. Wisser
JGJulia Grothe
Julia Grothe
Nasser Mohamed-NoriegaNasser Mohamed-Noriega
Nasser Mohamed-Noriega
SKStefan Kaskel
Stefan Kaskel

26 February 2024 in Polymers
Verified
Journal Article
Open access
PDF file
JPJesús Puente-Córdova
Jesús Puente-Córdova
Juan Francisco Luna-MartinezJuan Francisco Luna-Martinez
Juan Francisco Luna-Martinez
Nasser Mohamed-NoriegaNasser Mohamed-Noriega
Nasser Mohamed-Noriega
IMIsaac Yair Miranda-Valdez
Isaac Yair Miranda-Valdez
This work reports the dielectric behavior of the biopolymer ethyl cellulose (EC) observed from transient currents experiments under the action of a direct current (DC) electric field (~107 V/m) under vacuum conditions. The viscoelastic response of the EC was evaluated using dynamic mechanical analysis (DMA), observing a mechanical relaxation related to glass transition of around ~402 K. Furthermore, we propose a mathematical framework that describes the transient current in EC using a fractional differential equation, whose solution involves the Mittag–Leffler function. The fractional order, between 0 and 1, is related to the energy dissipation rate and the molecular mobility of the polymer. Subsequently, the conduction mechanisms are considered, on the one hand, the phenomena that occur through the polymer–electrode interface and, on the other hand, those which manifest themselves in the bulk material. Finally, alternating current (AC) conductivity measurements above the glass transition temperature (~402 K) and in a frequency domain from 20 Hz to 2 MHz were carried out, observing electrical conduction described by the segmental movements of the polymeric chains. Its electrical properties also position EC as a potential candidate for electrical, electronics, and mechatronics applications.

23 November 2023 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
RMRodolfo Morales-Avalos
Rodolfo Morales-Avalos
JDJosé Manuel Diabb-Zavala
José Manuel Diabb-Zavala
Nasser Mohamed-NoriegaNasser Mohamed-Noriega
Nasser Mohamed-Noriega
FVFélix Vilchez-Cavazos
Félix Vilchez-Cavazos
SPSimone Perelli
Simone Perelli
JMJoan Carles Monllau
Joan Carles Monllau
Background: Previous biomechanical studies of the meniscotibial ligament have determined that it contributes to meniscal stability. An injury to it can cause the meniscus to extrude, and reconstruction of that ligament significantly reduces extrusion. Purpose: To assess the biomechanical effects of sectioning the lateral meniscotibial ligament (LMTL) and the meniscofibular ligament (MFL) with respect to the radial mobility of the lateral meniscus and to evaluate the biomechanical effects of the capsulodesis and centralization techniques. Study Design: Controlled laboratory study. Methods: The lateral meniscus of 22 porcine knees was evaluated. They were mounted on a testing apparatus to apply muscle and ground-reaction forces. The meniscus was evaluated at 30° and 60° of knee flexion using 2 markers placed on the posterior cruciate ligament and the lateral meniscus after applying an axial compression of 200 N to the knee joint. Measurements were recorded under 5 conditions: intact lateral meniscus, injury of the LMTL, subsequent injury of the MFL, the use of the open capsulodesis technique, and the reconstruction of the LMTL and the MFL with the centralization technique. Results: The distance between the 2 markers was significantly greater in the extrusion group (combined lesion of the LMTL and MFL) than in the intact or reconstruction groups (capsulodesis and centralization techniques; P < .001 in all cases). In the cases of load application, no significant differences were observed between the control group (intact meniscus) and the groups on which the reconstruction techniques were performed. There were also no differences when comparing the results obtained between both reconstruction techniques. In all settings, the distance between the 2 markers increased with the increase in the knee flexion angle. Conclusion: In a porcine model, the LMTL and the MFL participated as restrictors of the radial mobility of the lateral meniscus during loading. Their injury caused a significant increase in lateral meniscal extrusion, and the centralization and the capsulodesis procedures were able to reduce extrusion. Clinical Relevance: This study demonstrates the capacity of the LMTL and the MFL to restrict the radial mobility of the lateral meniscus during loading and how it is affected when they are injured.