Navneet Gupta

Dr. Navneet Gupta

Birla Institute of Technology and Science, Pilani
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SBSuraj Baloda
Suraj Baloda
ZAZeeshan Alam Ansari
Zeeshan Alam Ansari
SSSumitra Singh
Sumitra Singh
Navneet GuptaNavneet Gupta
Navneet Gupta
Recently, flexible electronic devices have gained tremendous research interest owing to their wide range of applications such as human motion detection, health monitoring and electronic skin (E-Skin). Particularly, the development of skinlike flexible strain sensors is gradually increasing for the realization of multipurpose human-machine interfaces. This paper aims to propose a simple method of manufacturing flexible graphene-based strain sensors with high sensitivity. Herein, a novel flexible resistive-strain sensor based on graphene nanoplatelets (GNP)/PDMS has been reported that provides good strain sensitivity, stretchability up to 65% with a gauge factor of 62.5, indicating typical piezo-resistive characteristics. The fabricated sensor is attached to the human body, it works as a healthmonitoring device by detecting various human motions such as human wrist pulse measurement, the finger bending movement and in addition to the flexible pipe bending. This work presents fabrication, characterization and comparative study of four different types of GNP wrist pulse sensors. Therefore, with its simple structure and low cost processing coupled with reasonably good piezo-resistive behavior, it has great potential in wearable electronics, viz. human motion detection and health monitoring applications.

16 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PSPRAVEEN KUMAR SHARMA
PRAVEEN KUMAR SHARMA
Navneet GuptaNavneet Gupta
Navneet Gupta
PDPlamen I. Dankov
Plamen I. Dankov
In this paper, a complete analysis of the complex dielectric constant of a flexible substrate from the silicon-based polymer- Polydimethylsiloxane (PDMS) is performed, and the obtained results are discussed. Two experimental methods are applied in this research. The first Two-resonator method is based on resonance measurements by excitation of two types of TE- and TM-mode cylinder resonators with PDMS disks, ensure an accurate determination of the dielectric constant and dielectric loss tangent in both parallel and perpendicular directions (e.g., ε par and ε perp ). The second method is based on the tight coverage of planar microstrip ring resonators with non- metalized PDMS samples gives reliable information for the equivalent dielectric parameters (e.g., ε eq , tan δ εeq ). The obtained results show that PDMS substrates have relatively weak but measurable uniaxial anisotropy and well-expressed frequency dependencies of the extracted dielectric parameters in the range 1-40 GHz, namely ε par ~ 2.82-2.7; ε perp ~ 2.73-2.52 and ε eq ~ 2.75-2.64, tan δ εeq ~ 0.017-0.048. The results are confirmed by several other complementary methods. The considered pair of methods are also applied in the temperature interval-40/ + 70 ° C; the measured temperature dependencies on the dielectric parameters turn out to be relatively strong. The possible origin of the measured PDMS uniaxial anisotropy has been discussed; in fact, it appears mainly in the temperature range-30/ + 40 ° C.

2 January 2018 in Microelectronics International
Verified
Journal Article
Closed access
KKKavindra Kandpal
Kavindra Kandpal
Navneet GuptaNavneet Gupta
Navneet Gupta
Purpose: The purpose of this paper is to present a comprehensive review on development and future trends in zinc oxide thin film transistors (ZnO TFTs). This paper presents the development of TFT technology starting from amorphous silicon, poly-Si to ZnO TFTs. This paper also discusses about transport and device modeling of ZnO TFT and provides a comparative analysis with other TFTs on the basis of performance parameters. Design/methodology/approach: It highlights the need of high–k dielectrics for low leakage and low threshold voltage in ZnO TFTs. This paper also explains the effect of grain boundaries, trap densities and threshold voltage shift on the performance of ZnO TFT. Moreover, it also addresses the challenges like requirement of stable p-type ZnO semiconductor for various electronic applications and high value of ZnO mobility to meet growing demand of high-definition light emitting diode TV (HD-LED TV). Findings: This review will motivate the readers to further investigate the conduction mechanism, best alternate for gate-dielectric and the deposition technique optimization for the enhancement of the performance of ZnO TFTs. Originality/value: This is a literature review. The technological evolution of TFT in general and ZnO TFT in particular is presented in this paper.

2 November 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
SBSuraj Baloda
Suraj Baloda
Navneet GuptaNavneet Gupta
Navneet Gupta
SSSumitra Singh
Sumitra Singh
The multiwalled carbon nanotubes/ polydimethylosiloxane (MWCNT/PDMS) composite based pressure sensor has been widely adopted in wearable health care devices and electronic-skins due to its high flexibility, piezoresistivity, high sensitivity over a broad linear range and biocompatibility. Herein, MWCNT/PDMS composites with different MWCNT contents were fabricated and their mechanical and electrical characteristics were evaluated in detail for each case. The MWCNT/PDMS composite pressure sensors shows high sensitivity (0.02715–0.08283 kPa $^{\text{-1}}$ ) over large pressure sensing range from 0.1 to 100 kPa. In addition, through the cyclic stretching test, the strain-sensing properties of the MWCNT composite shows high reliability over 1000 repetitive cycles. The flexible devices can be used as the wearable electronic skin and successfully mounted on human skin to achieve the capability of physiological stimuli monitoring, i.e., human wrist pulse wave for health care applications. The wide linear working range with high sensitivity of the MWCNT/PDMS pressure sensor makes it a potential choice in flexible electronics such as wearable devices for health care monitoring, soft robotics and E-skin application.

22 February 2022 in IEEE Journal on Flexible Electronics
Verified
Journal Article
Closed access
PSPRAVEEN KUMAR SHARMA
PRAVEEN KUMAR SHARMA
Navneet GuptaNavneet Gupta
Navneet Gupta
This paper presents a 50 × 40 mm2 CPW-fed triple-band flexible antenna operating at 5 GHz, 5.5 GHz and 6.6 GHz for WLAN and WBAN applications. In the proposed design, Polydimethylsiloxane (PDMS) is used as a substrate with a dielectric constant εr of 2.65 and a loss tangent tanδεr of 0.02. In addition to the rectangular slot on the ground, the presented antenna has a single circular split-ring resonator (SRR) structure on the same side of the patch. This provides the required frequency notched characteristics for the targeted frequency bands, compactness, minimize losses, and backward radiation when used in close proximity to the human body. The proposed flexible antenna provides stable results in terms of performance parameters and specific absorption rate (SAR). We have also investigated the antenna under different operating conditions of moisture and bending. There exists a strong correlation between the simulation and measured findings.

15 September 2013 in Wireless Personal Communications
Verified
Journal Article
Closed access
PDF file
JKJitendra Kumar
Jitendra Kumar
Navneet GuptaNavneet Gupta
Navneet Gupta