Bimaterial cantilevers have recently been used in, for example, the calorimetric analysis with picowatt resolution in microscopic space based on state-of-the-art atomic force microscopes. However, thermally induced effects usually change physical properties of the cantilevers, such as the resonance frequency, which reduce the accuracy of the measurements. Here, we propose an approach to circumvent this problem that uses an optical microcavity formed between a metallic layer coated on the back of the cantilever and one coated at the end of an optical fiber irradiating the cantilever. In addition to increasing the sensitivity, the optical rigidity of this system diminishes the thermally induced frequency shift. For a coating thickness of several tens of nanometers, the input power is 5–10 μW. These values can be evaluated from parameters derived by directly irradiating the cantilever in the absence of the microcavity. The system has the potential of using the cantilever both as a thermometer without frequency shifting and as a sensor with nanometer-controlled accuracy.
The semiclassical approach consisting of Boltzmann equations for the excited states and the ground state supplemented by a Master equation for the probability distribution of the condensate population is solved for picosecond pulsed microcavity polaritons. With the simple birth- and death-type Master equation for the condensate population that disregards the condensate phase, one gets results, which, compared to quasistationary solutions, are in better agreement with the experiments. First, the time-dependent solutions show the influence of the change to the coherent state already at pump powers close above the condensate threshold. Second, and even more important for the interpretation of corresponding pulsed experiments, the time-dependent solution give results for the second-order correlation function with seemingly larger correlations above threshold, although no polariton-polariton interaction in the ground state has been included.
1 June 2017 in Japanese Journal of Applied Physics
We theoretically study the dynamics of an atomic force microscope cantilever under various irradiation configurations of a laser. By conveying a stream of photons and its momenta, the laser beam whose geometrical intensity profile has a Gaussian form will exert a nonuniform radiation pressure on the cantilever surface and modify its vibration. The dependences of cantilever modeshapes on the laser spot position and waist reveal a possibility of diminishing or exciting a specific eigenmode. For cantilevers of ∼200 µm length, the vibration amplitude of higher-order eigenmodes can be increased 4–5 times. This implies the change in cantilever effective mass once the interaction with the ambient is taken into account. The study gives a deeper understanding of soft cantilever dynamics in liquids and can be applied in the modern measurement configuration where high frequencies are required.