Nicolas Herzig

Dr. Nicolas Herzig

Department of Engineering and Design, University of Sussex, Brighton, Brighton and Hove, UK
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
Nicolas HerzigNicolas Herzig
Nicolas Herzig
PMPerla Maiolino
Perla Maiolino
FIFumiya Iida
Fumiya Iida
TNThrishantha Nanayakkara
Thrishantha Nanayakkara
During abdominal palpation diagnosis, a medical practitioner would change the stiffness of their fingers in order to improve the detection of hard nodules or abnormalities in soft tissue to maximize the haptic information gain via tendons. Our recent experiments using a controllable stiffness robotic probe representing a human finger also confirmed that such stiffness control in the finger can enhance the accuracy of detecting hard nodules in soft tissue. However, the limited range of stiffness achieved by the antagonistic springs variable stiffness joint subject to size constraints made it unsuitable for a wide range of physical examination scenarios spanning from breast to abdominal examination. In this letter, we present a new robotic probe based on a variable lever mechanism able to achieve stiffness ranging from 0.64 to 1.06 N·m/rad that extends the maximum stiffness by around 16 times and the stiffness range by 33 times. This letter presents the mechanical model of the novel probe, the finite element simulation as well as experimental characterization of the stiffness response for lever actuation.

10 February 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
SSS.M.HAdi Sadati
S.M.HAdi Sadati
ASAli Shiva
Ali Shiva
Nicolas HerzigNicolas Herzig
Nicolas Herzig
CRCaleb D. Rucker
Caleb D. Rucker
HHHelmut Hauser
Helmut Hauser
TNThrishantha Nanayakkara
Thrishantha Nanayakkara
In this letter, we propose benefiting from load readings at the base of a continuum appendage for real-time forward integration of Cosserat rod model with application in configuration and tip load estimation. The application of this method is successfully tested for stiffness imaging of a soft tissue, using a 3-DOF hydraulically actuated braided continuum appendage. Multiple probing runs with different actuation pressures are used for mapping the tissue surface shape and directional linear stiffness, as well as detecting non-homogeneous regions, e.g. a hard nodule embedded in a soft silicon tissue phantom. Readings from a 6-axis force sensor at the tip is used for comparison and verification. As a result, the tip force is estimated with 0.016–0.037 N (7–20%) mean error in the probing and 0.02–0.1 N (6–12%) in the indentation direction, 0.17 mm (14%) mean error is achieved in estimating the surface profile, and 3.4–15 [N/m] (10–16%) mean error is observed in evaluating tissue directional stiffness, depending on the appendage actuation. We observed that if the appendage bends against the slider motion (toward the probing direction), it provides better horizontal stiffness estimation and better estimation in the perpendicular direction is achieved when it bends toward the slider motion (against the probing direction). In comparison with a rigid probe, $\approx \!\!10$ times smaller stiffness and $\approx \!\!7$ times larger mean standard deviation values were observed, suggesting the importance of a probe stiffness in estimation the tissue stiffness.

1 April 2018 in Control Engineering Practice
Verified
Journal Article
Open access
Nicolas HerzigNicolas Herzig
Nicolas Herzig
RMRichard Moreau
Richard Moreau
TRTanneguy Redarce
Tanneguy Redarce
FAFrédéric Abry
Frédéric Abry
XBXavier Brun
Xavier Brun
International audienceThis paper presents an architecture of a 2 Degrees of Freedom pneumatic robot which can be used as a haptic interface. To improve the haptic rendering of this device, a nonlinear position and stiffness controller without force measurement based on a Backstepping synthesis is presented. Thus, the robot can follow a targeted trajectory in Cartesian position with a variable compliant behavior when disturbance forces are applied. An appropriate tuning methodology of the closed-loop stiffness and closed-loop damping of the robot is given to obtain a desired disturbance response. The models, the synthesis and the stability analysis of this controller are described in this paper. Two models are presented in this paper, the first one is an accurate simulation model which describes the mechanical behavior of the robot, the thermodynamics phenomena in the pneumatic actuators, and the servovalves characteristics. The second model is the model used to synthesize the controller. This control model is obtained by simplifying the simulation model to obtain a MIMO strict feedback form. Finally, some simulation and experimental results are given and the controller performances are discussed and compared with a classical linear impedance controller

29 December 2020 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
LHLiang He
Liang He
Nicolas HerzigNicolas Herzig
Nicolas Herzig
Simon de LusignanSimon de Lusignan
Simon de Lusignan
LSLuca Scimeca
Luca Scimeca
PMPerla Maiolino
Perla Maiolino
TNThrishantha Nanayakkara
Thrishantha Nanayakkara
Robotic phantoms enable advanced physical examination training before using human patients. In this article, we present an abdominal phantom for palpation training with controllable stiffness liver nodules that can also sense palpation forces. The coupled sensing and actuation approach is achieved by pneumatic control of positive-granular jammed nodules for tunable stiffness. Soft sensing is done using the variation of internal pressure of the nodules under external forces. This article makes original contributions to extend the linear region of the neo-Hookean characteristic of the mechanical behavior of the nodules by 140% compared to no-jamming conditions and to propose a method using the organ level controllable nodules as sensors to estimate palpation position and force with a root-mean-square error of 4% and 6.5%, respectively. Compared to conventional soft sensors, the method allows the phantom to sense with no interference to the simulated physiological conditions when providing quantified feedback to trainees, and to enable training following current bare-hand examination protocols without the need to wear data gloves to collect data.

6 November 2019 in IEEE Sensors Journal
Verified
Journal Article
Open access
HWHasitha Wegiriya
Hasitha Wegiriya
Nicolas HerzigNicolas Herzig
Nicolas Herzig
SASara-Adela Abad
Sara-Adela Abad
SSS.M. Hadi Sadati
S.M. Hadi Sadati
TNThrishantha Nanayakkara
Thrishantha Nanayakkara
Mammals like rats, who live in dark burrows, heavily depend on tactile perception obtained through the vibrissal system to move through gaps and to discriminate textures. The organization of a mammalian whisker follicle contains multiple sensory receptors and glands strategically organized to capture tactile sensory stimuli of different frequencies. In this paper, we used a controllable stiffness soft robotic follicle to test the hypothesis that the multimodal sensory receptors together with the controllable stiffness tissues in the whisker follicle form a physical structure to maximize tactile information. In our design, the ring sinus and ringwulst of a biological follicle are represented by a linear actuator connected to a stiffness controllable mechanism in-between two different frequency-dependent data capturing modules. In this paper, we show for the first time the effect of the interplay between the stiffness and the speed of whisking on maximizing a difference metric for texture classification.

11 September 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
SASara-Adela Abad
Sara-Adela Abad
Nicolas HerzigNicolas Herzig
Nicolas Herzig
DRDuncan Raitt
Duncan Raitt
MKMartin Koltzenburg
Martin Koltzenburg
HWHelge Wurdemann
Helge Wurdemann
Several gaps persist in haptic device development due to the multifaceted nature of the sense of touch. Existing gaps include challenges enhancing touch feedback fidelity, providing diverse haptic sensations, and ensuring wearability for delivering tactile stimuli to the fingertips. Here, we introduce the Bioinspired Adaptable Multiplanar Haptic system, offering mechanotactile/steady and vibrotactile pulse stimuli with adjustable intensity (up to 298.1 mN) and frequencies (up to 130 Hz). This system can deliver simultaneous stimuli across multiple fingertip areas. The paper includes a full characterisation of our system. As the device can play an important role in further understanding human touch, we performed human stimuli sensitivity and differentiation experiments to evaluate the capability of delivering mechano-vibrotactile, variable intensity, simultaneous, multiplanar and operator agnostic stimuli. Our system promises to accelerate the development of touch perception devices, providing painless, operator-independent data crucial for researching and diagnosing touch-related disorders.