Nora Vogt

Ms. Nora Vogt

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

4 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CWChristian Weihsbach
Christian Weihsbach
NVNora Vogt
Nora Vogt
ZHZiad Al-Haj Hemidi
Ziad Al-Haj Hemidi
ABAlexander Bigalke
Alexander Bigalke
LHLasse Hansen
Lasse Hansen
MHMattias P. Heinrich
Mattias P. Heinrich
In cardiac cine imaging, acquiring high-quality data is challenging and time-consuming due to the artifacts generated by the heart’s continuous movement. Volumetric, fully isotropic data acquisition with high temporal resolution is, to date, intractable due to MR physics constraints. To assess whole-heart movement under minimal acquisition time, we propose a deep learning model that reconstructs the volumetric shape of multiple cardiac chambers from a limited number of input slices while simultaneously optimizing the slice acquisition orientation for this task. We mimic the current clinical protocols for cardiac imaging and compare the shape reconstruction quality of standard clinical views and optimized views. In our experiments, we show that the jointly trained model achieves accurate high-resolution multi-chamber shape reconstruction with errors of 80%, indicating its effectiveness in both simulated cardiac cine MRI and clinical cardiac MRI with a wide range of pathological shape variations.

24 February 2026 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
NVNora Vogt
Nora Vogt
KIKaryna Isaieva
Karyna Isaieva
JLJean-Sébastien Louis
Jean-Sébastien Louis
PVPierre-André Vuissoz
Pierre-André Vuissoz
JFJacques Felblinger
Jacques Felblinger
JOJulien Oster
Julien Oster

3 June 2026 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
NVNora Vogt
Nora Vogt
SLSonia Lebza
Sonia Lebza
JFJacques Felblinger
Jacques Felblinger
GBGilles Bosser
Gilles Bosser
FOFreddy Odille
Freddy Odille
Oxygenation-sensitive (OS) cardiovascular magnetic resonance (CMR), using breathing maneuver-induced stress and blood oxygen level-dependent contrast, is a well-tolerated, non-invasive approach for assessing myocardial oxygenation. This study evaluated two real-time CMR sequences and a semi-automated analysis workflow to enable continuous, motion-robust assessment of myocardial oxygenation dynamics, aiming to overcome limitations of electrocardiogram (ECG)-triggered acquisitions and reduce manual evaluation requirements. Signal intensity dynamics of ten young healthy female volunteers were analyzed from images acquired on a 3T scanner using an ECG-triggered balanced steady-state free precession (bSSFP) sequence, a real-time (RT) bSSFP sequence, and a RT fast low-angle short (FLASH) sequence. Images were obtained in a mid-ventricular slice while participants performed a breathing maneuver consisting of normal breathing, paced hyperventilation, and a prolonged breath hold. A semi-automated processing pipeline was implemented to generate motion-resolved oxygenation maps using retrospective cardiac phase binning, deformable image registration, and automated segmentation. The RT sequences captured end-systolic global myocardial signal intensity change (ΔSI, relative to reference frames at breath-hold start) with dynamics comparable to those of the ECG-triggered bSSFP sequence. As expected in healthy volunteers, ΔSI decreased during hyperventilation and recovered during the prolonged breath-hold. At 20-30s, oxygenation responses at end-systole were 3.95%[3.36, 7.50] for ECG-triggered bSSFP, 5.47%[3.31, 9.08] for RT bSSFP, and 3.24%[1.99, 4.80] for RT FLASH. RT FLASH showed fewer artifacts but lower contrast and smaller ΔSI than the bSSFP sequences, with inter-sequence differences appearing modest in mixed-effects analysis. This exploratory study demonstrates the feasibility of combining real-time MR sequences with a semi-automated processing pipeline for continuous assessment of T2∕T2*-related myocardial oxygenation dynamics. Potential confounders, including through-plane motion and physiological drift, warrant further investigation.